| ELECTRIC
STRIKES |
VOLTAGE |
| Available in 12, 16 or 24 volt AC
and DC. DC and AC Continuous units are silent, AC intermittent units
"buzz" on operation. |
CURRENT DRAW/LAMPS |
| Volts |
AC Int. |
DC or AC Cont. |
| 12 |
1.42 |
.33 |
| 16 |
1.03 |
.22 |
| 24 |
.74 |
.17 |

Case
Approx. 1" x 3-3/8" x 1-13/16" deep. Made of
Zinc-aluminum alloy.
Strike Lip
Basic 7170 strikes have lip of proper length for
1-3/4" thick door that closes flush with jamb edge. Where door thickness or jamb
shape differs from this standard relationship, extended lip is available, specified
by last dash number.
Function
Remote electrical control of any door equipped with one of
the Mortise Type latchsets listed above. Electrical actuation unlocks strike jaw,
releasing latchbolt so door can be opened without operating latch itself. Extremely
compact mechanism fits shallow as 1-7/8". Fits preps for 7560AN/ 7860AN and
7570/7870.
Strike Openings
3/4" x 1-7/16" x 3/4" deep. Bolt retainer
jaw is made of stainless steel. Strike accepts bolt of the following latchsets (or panic
exit devices) when it is centered on strike:
| All 3/4" THROW LATCHES
REQUIRE 1/8" OR MORE DOOR GAP. |
| ARROW |
861-1/2, 871-1/2 |
| BEST |
30H SERIES |
| BALDWIN |
6000 SERIES |
| CORBIN |
528, 0548, 9200, 9300, 9500, 9700 |
| FALCON |
M1000, M2000, M3000 |
| LOCKWOOD |
T500, F500, B5100, 5500 |
| MONARCH |
XXM, CVM, 11M |
| PRECISION |
820, 830 |
| RUSSWIN |
2000, 3000, 5000, 7000, T-7000, 1454 |
| SCHLAGE |
"L" LATCHES |
| UNICAN |
1000 |
| VON DUPRIN |
34, 58, 7500 |
| YALE |
62 |
Faceplate
Measures 1-1/4" x 4-7/8". Faceplate is flat, with
square corners. Available in our full range of architectural finishes.
Fail Safe/Fail Secure
Field convertible from one mode to the other. However, AC
intermittent solenoid must not be used continuously in either.
| ADAMS RITE MANUFACTURING CO. |
 |
4040 S. CAPITOL AVE., P.O. BOX 1301 CITY OF INDUSTRY,
CALIFORNIA 91749 (562) 699-0511 FAX : (562) 699-5094 |
|