Electric Strikes - Page 27

   

Electric Strikes

ES-36N 4611

INCHES MILLIMETERS

DIMENSIONS

DIMENSIONS IN PARENTHESIS ARE FOR LONG WIRE TRANSFER DEVICE (180°) ONLY.

WIRE TRANSFER

INSTALLATION

DOOR & FRAME PREP

  1. Dimensions in parentheses are for long wire transfer device (180º) only.
  2. For wood frame the rectangular cutout is 11/16" deep min.
  3. Transfer is designed to protect the wire. Care should also be taken when inserting wires through this device.
  4. Only stranded wires to be employed.
  5. Size and number of wires must comply with the National Electric Code, NFPA and local authorities having jurisdiction. Wire size shall be at least 22 gauge.
  6. This device is intended for low voltage use only ( 30 VAC, 42.5 VDC, 10 W max.)
  7. Wire should be labeled, appliance wiring material with minimum 1/32" thick insulation.