Electric Strikes - Page 27
Electric Strikes
| ES-36N |
4611 INCHES MILLIMETERS |
|
|
DIMENSIONS IN PARENTHESIS ARE FOR LONG WIRE TRANSFER DEVICE
(180°) ONLY.


WIRE TRANSFER
DOOR & FRAME PREP

- Dimensions in parentheses are for long wire transfer device
(180º) only.
- For wood frame the rectangular cutout is 11/16" deep
min.
- Transfer is designed to protect the wire. Care should also
be taken when inserting wires through this device.
- Only stranded wires to be employed.
- Size and number of wires must comply with the National
Electric Code, NFPA and local authorities having jurisdiction. Wire size shall be at least
22 gauge.
- This device is intended for low voltage use only ( 30 VAC,
42.5 VDC, 10 W max.)
- Wire should be labeled, appliance wiring material with
minimum 1/32" thick insulation.
|