Alkco Lighting
Flare - Advancing The Art Of Wall Illumination
Flare¿
Flare - Advancing The Art Of Wall Illumination

| A. | Visual uniformity
without striations
So, next time you need to uniformly illuminate walls or vertical displays, do it with Flare. |
| B. | High Reflectance White Optics Flare's extruded aluminum reflector is finished with a high-reflectance white powder coat finish. This durable coating does not show dust or fingerprints, has high lumen maintenance and matches the appearance of white ceilings. |
| C. | Sharp Ceiling/ Wall Light Cut-OffThe light distribution from Flare cuts off precisely at the ceiling/wall juncture. |
Optimal Performance In Grid And Drywall Ceilings
Flare is designed to maintain sharp ceiling cut-off whether installed in grid or drywall ceilings... and its low 4" profile helps circumvent plenum obstructions.
|
|
Uniform Illumination
Flare's unique reflector system provides uniform illumination without striations, scallops or hot spots.
Vertical
Footcandles with front of Luminaire 3' from wall |
|||||||||||
Single Luminaire |
Multiple Luminaires |
||||||||||
Distance From |
8' O.C. |
12' O.C. |
|||||||||
|
2' |
4' |
6' |
8' |
|
4' |
|
|
6' |
|
|
Ceiling |
|||||||||||
1' |
81 |
38 |
13 |
5 |
3 |
86 |
27 |
86 |
84 |
11 |
84 |
2' |
69 |
42 |
17 |
7 |
4 |
76 |
35 |
76 |
71 |
15 |
71 |
3' |
44 |
31 |
15 |
7 |
4 |
51 |
33 |
51 |
47 |
15 |
47 |
4' |
27 |
22 |
12 |
7 |
4 |
34 |
27 |
34 |
29 |
14 |
29 |
5' |
18 |
15 |
10 |
6 |
4 |
24 |
21 |
24 |
20 |
12 |
20 |
6' |
12 |
11 |
8 |
5 |
3 |
18 |
18 |
18 |
14 |
10 |
14 |
7' |
9 |
8 |
6 |
4 |
3 |
14 |
14 |
14 |
11 |
9 |
11 |
8' |
6 |
5 |
4 |
3 |
2 |
10 |
10 |
10 |
7 |
6 |
7 |
*multiply values by 1.27 to convert to F50 BX lamp.
Ordering Information |
|||
| Catalog # | |||
| Grid | Flange | Lamps | Length |
| FWW-117-F | 1/F17T8 | 2' |
|
| FWW-132-F | 1/F32T8 | 4' |
|
| FWW-140-G | FWW-140-F | 1/FT40W/2G11/RS | 2' |
| FWW-240-G | FWW-240-F | 2/FT40W/2G11/RS | 4' |
| FWW-150-G | FWW-150-F | 1/FT50W/2G11/RS | 2' |
| FWW-250-G | FWW-250-F | 2/FT50W/2G11/RS | 4' |
| Electrical Options | |||
| /277V | 277 Volt Ballast | ||
| /SLO-BLO | GMF-Slow Blow Fuse and Fuseholder | ||
Premium high-frequency electronic rapid start ballast is standard.
| |
| A JJI Lighting Group Company 11500 Melrose Avenue Franklin Park, Illinois 60131-8389 Phone: (847-451-0700 Fax: (847-451-7512 Visit Our Web Site: www.alkco.com |





Flare's extruded aluminum, powder-coated design is also cost effective and
maintains initial performance throughout the life of an installation.
Sharp Ceiling/ Wall Light Cut-Off