 K60 Control |
 K30 Control |
THE "AK" SERIES: Superior Control and Comfort
The Amerec AK series steambath generator combines
operating simplicity with the most advanced temperature sensing system of its kind. You
may select either of two available AK controls which can be mounted inside or outside the
steamroom. You can also install dual controls-one inside the steamroom and another any
place within twenty-five feet of the generator location.
The K60 control features a digital display that alternately displays
ambient room temperature and time remaining. The three button panel includes on/off
temperature setting and time setting controls, which can be adjusted up to 60 minutes. The
K60 retains memory of the previous temperature and time settings.
The display window of the K30 lights up when the generator is on. It
has a built-in 30 minute timer and an adjustable temperature range from 100° to 125°F. A
simple on/off switch operates the generator.
The AK generator features innovative "soft steam" element
switching to maintain a consistent and comfortable steambath environment. Unlike
conventional thermostatically controlled generators, the AK utilizes full power to quickly
heat up the steamroom to its present temperature.Then, the AK cuts power to half its
elements, resulting in a more continuous flow of soft,billowing steam.Comparative testing
provides proof of the superior performance resulting from "soft steam" element
switching, a feature exclusive to the Amerec AK generator.
A manual drain valve is standard, and an optional automatic flush
system is available. The AK controls, "cool touch" steamheads and escutcheons
are available in polished chrome, polished brass, polished nickel, brushed nickel,
polished gold or white.
 Temperature Sensor |
 Cool Touch Steam Outlet |
| MODEL |
WIRE SIZE |
**
PHASE |
VOLT |
AMP |
BREAKER SIZE |
KW |
* MAX CU.FT. |
| AK5 |
10-2
W/G |
1 |
240 |
21.0 |
35 |
5.0 |
100 |
| 208 |
18.0 |
30 |
3.7 |
60 |
| AK7 |
8-2
W/G |
1 |
240 |
29.0 |
45 |
7.0 |
220 |
| 208 |
25.3 |
40 |
5.2 |
110 |
| AK10 |
6-2
W/G |
1 |
240 |
41.5 |
60 |
10 |
400 |
| 208 |
36.1 |
60 |
7.5 |
250 |
| AK17 |
For
electrical specifications
please call the factory at 1-800-331-0349 |
725 |
| AK20 |
900 |
| AK30 |
1350 |

Shipping:Weight 36lbs, Size: 27" x 18" x 9-1/2"
This symbol of the product's nameplate means it is listed by
UNDERWRITERS' LABORATORIES

R30i Control
THE " AR" SERIES:Simple and Economical
An easy-to-use alternative, the AR is operated with the new R30i
control, a simple on/off switch which can be mounted inside or outside the steam room,
eliminating the need for an optional air switch. When the "on" button is pushed,
the green indicator light tells the bather the generator is on and steam appear in
minutes. The AR has a built-in 30 minute timer which turns the generator off.
The AR features "whisper quiet" operation and "space
saver" reversible installation. A manual drain valve is standard, and an optional
automatic flush system is available. You can install dual controls, one inside the steam
room and one outside, anyplace within 100 feet of the generator location.
The R30i control, "cool touch" steamhead and
escutcheon are available in polished chrome, polished brass and white finishes.
| MODEL |
WIRE SIZE |
* *
PHASE |
VOLT |
AMP |
BREAKER SIZE |
KW |
* MAX CU. FT. |
| AR4 |
10-2
W/G |
1 |
240 |
17.0 |
30 |
4.0 |
75 |
| 208 |
14.5 |
25 |
3.0 |
50 |
| AR5 |
10-2
W/G |
1 |
240 |
21.0 |
35 |
5.0 |
100 |
| 208 |
18.0 |
30 |
3.7 |
60 |
| AR6 |
8-2
W/G |
1 |
240 |
25.0 |
40 |
6.0 |
160 |
| 208 |
21.7 |
35 |
4.5 |
85 |
| AR7 |
8-2
W/G |
1 |
240 |
29.0 |
45 |
7.0 |
220 |
| 208 |
25.3 |
40 |
5.2 |
110 |
| AR8.5 |
6-2
W/G |
1 |
240 |
35.5 |
60 |
8.5 |
300 |
| 208 |
30.7 |
0 |
6.4 |
190 |
| AR10 |
6-2
W/G |
1 |
240 |
41.5 |
60 |
10.0 |
400 |
| 208 |
36.1 |
60 |
7.5 |
250 |
| AK17 |
For
electrical specifications
please call the factory at 1-800-331-0349 |
725 |
| AK20 |
900 |
| AK30 |
1350 |

Shipping:Weight 36lbs, Size: 27" x 18" x 9-1/2"
This symbol of the product's nameplate means it is listed by
UNDERWRITERS' LABORATORIES
* IMPORTANT : The maximum cubic footage is for reference only.
Complex room construction and material variables may substantially alter the model
required for your installation. For further information see "The Steam Room
Construction and Generator Sizing Guide". Manufacturers of the room construction
materials should be consulted for approval of material use in a steam room environment.
**NOTE: Contact factory for information concerning 3 phase operation
and ganging multiple units. |