APA Residential & Commercial - Page 25

   

APA Residential & Commercial

TABLE 8

APA RATED STURD-I-FLOOR(a)

       

Fastening: Glue-Nailed(c)

Fastening: Nailed-Only

            Maximum Spacing (in.)   Maximum Spacing (in.)
Span Rating (Maximum Joist Spacing) (in.) Panel Thickness (b) (in.) Nail Size and Type Supported Panel
Edges (g)
Intermediate Supports Nail Size and Type Supported Panel
Edges (g)
Intermediate Supports
16 19/32, 5/8 6d ring- or screw-shank(d) 12 12 6d ring- or screw-shank 6 12
20 19/32, 5/8 6d ring- or screw-shank(d) 12 12 6d ring- or screw-shank 6 12
24 23/32, 3/4 6d ring- or screw-shank(d) 12 12 6d ring- or screw-shank 6 12
7/8 8d ring- or screw-shank(d) 6 12 8d ring- or screw-shank 6 12
32 7/8 8d ring- or screw-shank(d) 6 12 8d ring- or screw-shank 6 12
48 1-3/32, 1-1/8 8d ring- or screw-shank(e) 6 (f) 8d ring- or screw-shank(e) 6 (f)

(a) Special conditions may impose heavy traffic and concentrated loads that required construction in excess of the minimums shown. See page 36 for heavy duty floor recommendations.

(b) Panels in a given thickness may be manufactured in more than one Span Rating. Panels with a Span Rating greater than the actual joist spacing may be substituted for panels of the same thickness with a Span Rating matching the actual joist spacing. For example, 19/32-inch-thick Sturd-I-Floor 20 oc may be substituted for 19/32-inch-thick Sturd-I-Floor 16 oc over joists 16 inches on center.

(c) Use only adhesives conforming to APA Specification AFG-01 or ASTM D3498, applied in accordance with the manufacturer's recommendations. If OSB panels with sealed surfaces and edges are to be used, use only solvent-based glues;check with panel manufacturer.

(d) 8d common nails may be substituted if ring- or screw-shank nails are not available.

(e)10d common nails may be substituted with 1-1/8-inch panels if supports are well seasoned.

(f) Space nails maximum 6 inches for 48-inch spans and 12 inches for 32-inch spans.

(g) Fasten panels 3/8 inch from panel edges.

TABLE 9

RECOMMENDED UNIFORM FLOOR LIVE LOADS FOR APA RATED STURD-I-FLOOR AND APA RATED SHEATHING WITH LONG DIMENSIONS PERPENDICULAR TO SUPPORTS

              Allowable Live Loads (psf)(a)
            Joist Spacing (in.)
Sturd-I-Floor Span Rating Sheathing Span Rating Minimum Panel Thickness (in.) Maximum Span (in.) 12 16 20 24 32 40 48
16 oc 24/16,32/16 7/16(c) 16 185 100          
20 oc 40/20 19/32, 5/8 20 270 150 100        
24 oc 48/24 23/32, 3/4 24 430 240 160 100      
32 oc 60/32(b) 7/8 32   430 295 185 100    
48 oc   1-3/32, 1-1/8 48     460 290 160 100 55
(a) 10 psf dead load assumed. Live load deflection limit is l/360.

(b) Check with supplier for availability.

(c) 19/32 in. is minimum thickness of Rated Sturd-I-Floor.

Note: Shaded construction meets Code Plus recommendations.



Request for Information / Request a Catalog from APA - The Engineered Wood Association
 
 
 
To request more information from APA - The Engineered Wood Association, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.