architecture - engineering - construction
AECinfo.com
Printable version Bookmark this page Notify a colleague or friend about this page Bookmark and Share
  Ardee Lighting, Inc   Clickstrip  

Clickstrip - Page 23

   

Clickstrip

DOWNLIGHT HOUSINGS

INSULATION CONTACT ROUGH-IN

A30I

 

 

click23d.gif (5247 bytes)

REMODEL ROUGH-IN

A30R

 

STANDARD ROUGH-IN

A30S

 

 

  A30R A30S A30I
A 3" (76mm) 3" (76mm) 3" (76mm)
B 4-1/2" (114mm) 4-1/2" (114mm) 6-1/2" (165mm)
C 9-1/2" (241mm) 13" (330mm) 13-3/4" (349mm)
D 3" (76mm) 8-5/8" (219mm) 8-5/8" (219mm)

Rough-ins are approved for use in all ceiling types except concrete pour. To order Rough-in for use with a remote tranformer, add - 12 to the catalog number.

(Example: A30S-12).

A30I

  • Stamped galvanized steel frame and housing.
  • Adjustable hanger bars included, expand to 25" (144mm).
  • Galvanized steel junction box with pryout knockouts. Rated for through branch wiring, 4-in/4-out, #12 AWG wire, rated 90 degree C minimum. Accessible from below ceiling.
  • Class H electromagnetic transformer. 120 volt input, 12 volt output. Accessible from below ceiling.
  • Thermal Protector, opens circuit at 110 degrees C.
  • Female socket connector. Socket and male connector supplied with the Trim.
  • certified for safe use in direct contact with insulation.

A30R

  • Stamped galvanized steel can and connection box assembly.
  • Galvanized steel junction box with pryout knockouts. Rated for through branch wiring, 1-in/1-out, #12 AWG wire, rated 90 degree C minimum. Accessible from below ceiling.
  • Class H electromagnetic transformer. 120 volt input, 12 volt output.
  • Thermal Protector, opens circuit at 110 degrees C.
  • Female socket connector. Socket and male connector supplied with the Trim.
  • certified for safe use in ceilings without insulation, or where insulation is kept 3" away from all sides and 1" above.

A30S

  • Stamped galvanized steel frame.
  • Adjustable hanger bars included, expand to 25" (144mm).
  • Galvanized steel junction box with pryout knockouts. Rated for through branch wiring, 4-in/4-out, #12 AWG wire, rated 90 degree C minimum. Accessible from below ceiling.
  • Class H electromagnetic transformer. 120 volt input, 12 volt output. Accessible from below ceiling.
  • Thermal Protector, opens circuit at 110 degrees C.
  • Female socket connector. Socket and male connector supplied with the Trim.
  • certified for safe use in ceilings without insulation, or where insulation is kept 3" away on all sides, and 1" above.



Request for Information / Request a Catalog from Ardee Lighting, Inc
 
 
 
To request more information from Ardee Lighting, Inc, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.