 Barrier International Corp.  Construction  

Barrier Type B

 

 

BARRIER TYPE B

BARRIER Type B solvent based system is the original BARRIER coating. For 27 years BARRIER Type B has offered superior protection for brick, concrete (above and below grade), wood, metal and painted surfaces.

One of BARRIER Type B's outstanding features is its ability to remain water-clear. BARRIER never ambers! Where coloration is desired, BARRIER Type B may be pigmented to suit particular needs.

WATERPROOFING: BARRIER Type B prevents moisture penetration, freeze-thaw damage, spalling and chipping and crumbling of brick and concrete. BARRIER may be applied over other coating systems, and is designed to at least double the lifetime of an existing painted surface.

COOLS: BARRIER helps keep buildings cool by refracting infrared rays. BARRIER saves energy!

APPEARANCE: BARRIER will enhance the appearance of many surfaces while remaining durable and water clear. Even graffiti may be removed with a solvent wash!

PENETRATION: BARRIER's ability to perform these varied functions is largely due to its unique penetration. While most coatings merely lie on the surface, BARRIER actually penetrates up to 1/4" into the substrate offering added protection against moisture penetration and abrasions.
barr02a.JPG (31436 bytes)

ULTRAVIOLET RADIATION is responsible for most fading causing crowsfooting of organic coating systems. BARRIER is completely opaque to U.V. radiation in the ultraviolet frequencies below 2800 AU. This is one of the reasons why BARRIER provides prolonged film life when compared to so-called "similar products."

The surface to be sealed must be thoroughly clean and dry. Type B should be applied with a brush, roller, or airless-spray equipment. Type B will cover 250-300 sq. ft./gal. depending on the porosity of the surface.

PROPERTIES:
BARRIER Type B is available in 12%-40% solids. Test methods and additional data, including acid resistance, is available upon request.

TEST METHOD:

Total solids

28%

Fed Std Test 141 a
Method 4044
1

Sulfur Content, ppm

50 max.

Fed Std Test 141a
Method 4291
Fed Std Test 141a
Method 4282
Fed Test 141a
Method 6171

Flashpoint

106°F min.

Viscosity, #4 Ford Cup 10 sec

68

Moisture Vapor transmission rate
(dry -film max. grms/sq. meter/24 hrs.)

1.0

Fed Std Test 141 a
Method 6061
2

Weather resistance
accelerated weathering
closed arc

600 hrs. min.

Fed Std Test 141a
Method 6061
2
ASTM D 622-64T

Salt spray resistance
5% solution

600 hrs. min.

Elongation

125%

Hardness-Sward

 

 

2.5 hrs

11

Sward

5 hrs

15

24 hrs

22

168 hrs

31

 

Abrasion resistance
taber weight loss/
500 cycles-grams

0.0515 max.

Tabor

cycles to break through

350

 

Water & Alkali resistance

20,000 min.

Gardner #105 Scrub Machine

Dielectric strength volts per mil

10,000 min.

Air dry, to touch @ .006 mils wet

30 minutes

Fed Std Test 141 a Method 4061.13

Dry hard @ .006 mils wet

72 hrs.

Colorfastness

does not yellow or discolor

Stain resistance

dry film does not stain when exposed to oil and grease

Penetrability

1/8" - 1/4" , depending on porosity of surface

Flexibility 1/8" mandril

no cracking or breaking of film

Fed Std Test 141 a Method 62212

Wear resistance to weighted traffic

500 lbs./sq. in. without cracking or chipping

Corrosion resistance sulfuric acid 10%

slightly dull, no rusting

sulfurous acid 5%

slightly dull, no rusting

ASTM D5434 Procedure 1

nitric acid 5%

slightly dull, no rusting

acetic acid 5%

slightly dull, no rusting

chromic acid 5%

slightly dull, no rusting

calcium chloride 10%

no effect

hot water

slightly dull

(500 hrs.)
(160 deg. F 72 hrs.)

NOTES:
1 Addition of acetone and standing at room temperature is not necessary.
2 Panel Preparation, method 2001.1 Procedure A. Dip Panel in Liquid Barrier and allow to air dry for minimum of 72 hrs.
3 Applied at 3.0± mil wet thickness gives a 1.0± mil dry thickness.
4 Exposure time 168 hrs. Temperature 73 degrees F 1 mil film in metal.

 

Request for Information / Request a Catalog from Barrier International Corp.
 
 
 
To request more information from Barrier International Corp., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2009 AECinfo.com