One-Hour Floor/Ceiling Assembly

Fire Assembly Components

FIRE ASSEMBLY COMPONENTS

  1. 3/4" Tongue-and-groove plywood or 23/32" APA rated sheathing (Exposure 1 or exterior glue)
  2. BCI Joists at 24" o.c.
  3. Two layers 1/2" Type X Gypsum Board

SOUND ASSEMBLY COMPONENTS
when constructed with resilient channel(s)

  • Add Carpet & Pad to fire assembly: or
  • Add 3 1/2" Glass Fiber insulation to fire assembly: or
  • Add an additional layer of 5/8" T&G OSB and 9 1/2" glass fiber insulation to fire assembly:
Closest Allowable Nail Spacing

Connector
Size
BCI/40s
Nailing Perpendicular
to Glue Lines
BCI/45s & BCI/60s
Nailing Perpendicular
to Glue Lines
Nailing Parallel
to Glue Lines
O.C. Spacing End of Joist O.C. Spacing End of Joist O.C. Spacing

8d Box

2 1/2"

1 1/2"

2"

1 1/2"

4"

8d Common

3 1/2"

1 1/2"

2"

1 1/2"

6"

10d & 12d Box

3"

1 1/2"

2"

1 1/2"

6"

10d & 12d Common

4 1/2"

3"

3"

2"

6"

16d Sinker

4 1/2"

3"

3"

2"

6"

16d Common

6"

3"

3"

3"

10"

 

BCI Design Properties

Use BC CALC Software for specific design data.

DEPTH
(in)
WEIGHT
(lb/ft)
K x 106
(lb)
EI x 106
(lb-in2)
Max End Reaction (lb) Max. Intermediate Reaction (lb) Max.
Moment
(ft-lbs.)
No Web Stiffeners No Web Stiffeners
9 1/2" BCI 40s

2.2

5.13

157

900

1850

2694

11 7/8" BCI 40s

2.5

6.36

268

1000

2200

3595

14" BCI 40s

2.8

7.74

396

1100

2280

4408

9 1/2" BCI 45s

2.4

5.20

181

900

1850

3162

11 7/8" BCI 45s

2.7

6.43

309

1000

2200

4223

14" BCI 45s

3.0

7.55

456

1100

2280

5179

16" BCI 45s

3.2

8.60

623

1255

2640

6083

11 7/8" BCI 60s

3.3

6.55

401

1000

2200

5603

14" BCI 60s

3.5

7.68

589

1100

2280

6875

16" BCI 60s

3.8

8.74

802

1255

2640

8078

Equation

Reaction and moment values are based on 100% duration of load. Adjustments for various load durations are permitted when applicable by code.

Code Evaluations - ICBO ES ER-5208
BOCA ES 95-18
SBCCI PST & ESI 9643



Request for Information / Request a Catalog from Boise Cascade Engineered Wood Products
 
 
 
To request more information from Boise Cascade Engineered Wood Products, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.