Boise Cascade Engineered Wood Products
Western Engineered Wood Products Specifier Guide
BCI 450 Series Roof PLF Table
Western Engineered Wood Products Specifier Guide
Western EWP
Specifier Guide - 115% and 125%
BCI 450 Series Joist - 1 3/4" Flange Width
|
| Allowable Uniform
Roof Load In pounds per lineal foot (PLF) |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 9 1/2" BCI 450 | 11 7/8" BCI 450 | 14" BCI 450 | 16" BCI 450 | |||||||||
| Span (ft.) |
Total Load | Defl. | Total Load | Defl. | Total Load | Defl. | Total Load | Defl. | ||||
| Snow (115%) |
Non-snow (125%) |
L/240 | Snow (115%) |
Non-Snow (125%) |
L/240 | Snow (115%) |
Non-Snow (125%) |
L/240 | Snow (115%) |
Non-Snow (125%) |
L/240 | |
6 |
300 |
326 |
- |
330 |
359 |
- |
345 |
375 |
- |
360 |
392 |
- |
ROOF SPAN TABLE NOTES
- Total load limits deflection to L/180.
- For stiffer deflection criteria, use the L/240 column.
- Slope roof joist at least 1/4" over 12" to minimize ponding.
- Values represent the most restrictive of simple or continuous span.
- Span tables are based on shear values for minimum bearing lengths without web stiffeners for BCI depths of 16 inch and less. See BC Calc Software for higher shear values using web stiffeners or wider bearing lengths.