  Boise Cascade Engineered Wood Products   Western Engineered Wood Products Specifier Guide  

Versa-Lam Column Table

   

Western Engineered Wood Products Specifier Guide

Western EWP Specifier Guide - Versa-Lam Columns

The same properties that make Versa-Lam beams great, also make them highly suitable for wood columns. In Versa-Lam columns, you'll find none of the deep checks, cracks or twists that can plague solid wood columns and there's no need to box in Versa-Lam's good looks.

Versa-Lam Column Table

Length
(ft)
Allowable Axial Load (Lb)
100% Load Duration
3 1/2" x 3 1/2" 3 1/2" x 5 1/4" 3 1/2" x 7" 5 1/4" x 5 1/4" 5 1/4" x 7" 7" x 7"

4

15,160

...

...

...

...

...

5

12,655

18,990

...

...

...

...

6

10,385

15,590

20,790

...

...

...

7

8,555

12,840

17,125

29,745

...

...

8

7,125

10,690

14,260

26,200

34,950

...

9

6,000

9,005

12,010

22,995

30,675

...

10

5,110

7,675

10,235

20,220

26,970

...

11

4,400

6,605

8,810

17,850

23,810

...

12

3,825

5,740

7,660

15,835

21,120

...

13

3,355

5,035

6,715

14,115

18,830

...

14

2,960

4,445

5,930

12,650

16,875

33,415

15

...

...

...

11,390

15,195

30,490

16

...

...

...

10,305

13,745

27,900

17

...

...

...

9,360

12,490

25,600

18

...

...

...

8,540

11,390

23,560

19

...

...

...

7,820

10,430

21,740

20

...

...

...

7,185

9,580

20,110

21

...

...

...

6,620

8,830

18,655

22

...

...

...

...

...

17,345

23

...

...

...

...

...

16,160

24

...

...

...

...

...

15,095

Table assumes that the column is braced at column ends only. Effective column length is equal to actual column length.

NOTES

  • Allowable loads are based on solid, one piece column members used in dry service conditions.
  • Allowable loads incorporate an eccentricity value of 0.167 of column thickness (least dimension).
  • Allowable loads are based on axial loaded columns using the design provisions of the National Design Specification for Wood Construction (NDS), 1991 edition.
  • For side loading or other combined bending and axial loads, see provisions of NDS, 1991 edition.

Multiple Member Beams

Multiple Member Beams Diagram 1

Multiple Member Beams Diagram 2

Multiple Member Beams Diagram 3

Multiple Member Beams Diagram 1

Multiple Member Beams Diagram 5 Multiple Member Beams Diagram 6 Multiple Member Beams Diagram 7

 

Multiple Member Connections

Boise Cascade strongly recommends the use of single members
Side Loaded Connections

  Maximum Uniform Load (lbs. per lin. ft.)
Nailed 1/2" Through Bolt (b) 5/8" Through Bolt (b)

Number of
Members

2 rows 16d
commons
@ 12"o.c.

3 rows 16d
commons
@ 12"o.c.

2 rows
@ 24"o.c.
staggered

2 rows
@ 12"o.c.
staggered

2 rows
@ 6"o.c.
staggered

2 rows
@ 24" o.c.
staggered

2 rows
@ 12" o.c.
staggered

2 rows
@ 6" o.c.
staggered

1 3/4" Versa-Lam

2

520

780

500

1000

2000

560

1120

2240

3 (a)

390

585

375

750

1500

420

840

1680

4 (c)

use bolt schedule

330

670

1330

370

740

1490

3 1/2" Versa-Lam

2 (c)

use bolt schedule

860

1720

N/A

1120

2240

N/A

(a) The nail schedules shown apply to both sides of a three member beam.

(b) Design values apply to common bolts that conform to ANSI/ASME standard B18.21-1981. A washer not less than a standard cut washer shall be between the wood and the bolt head and between the wood and the nut. The distance from the edge of the beam to the bolt holes must be at least 2" for 1/2" bolts and 2 1/2" for 5/8" bolts. Bolt holes shall be the same diameter as the bolt.

(c) 7" wide beams must be loaded from both sides.

(d) Beams wider than 7" must be designed by engineer of record.

(e) All values in these tables may be increased by 15% for snow-load roofs where the building code allows.

(f) MINIMUM MULTIPLE MEMBER CONNECTIONS for top loaded beams and beams with side loads with less than those shown:

(2) 1 3/4" plies Depth 12" 2 rows 16d box or 3 1/2" x .131" nails @ 12" o.c. 400 plf maximum uniform load from one side
Depth > 12" 3 rows 16d box or 3 1/2" x .131" nails @ 12" o.c. 600 plf maximum uniform load from one side
(3) 1 3/4" plies Depth 12" 2 rows 16d box or 3 1/2" x .131" nails @ 12" o.c. 300 plf maximum uniform load from one side
Depth > 12" 3 rows 16d box or 3 1/2" x .131" nails @ 12" o.c. 450 plf maximum uniform load from one side
(4) 1 3/4" plies All Depths 2 rows 1/2" bolts @ 24" o.c. staggered 335 plf maximum uniform load from one side
(2) 3 1/2" plies All Depths 2 rows 1/2" bolts @ 24" o.c. staggered 860 plf maximum uniform load from one side

(g) Use allowable load tables or BC CALC software to size beams.



Request for Information / Request a Catalog from Boise Cascade Engineered Wood Products
 
 
 
To request more information from Boise Cascade Engineered Wood Products, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.