Boise Cascade Engineered Wood Products
Western Engineered Wood Products Specifier Guide
Framing Connectors
Western Engineered Wood Products Specifier Guide
| Western EWP Specifier Guide - Framing Connectors |
|---|
SINGLE BCI JOISTS

| JOIST HEIGHT |
TOP FLANGE |
FACE MOUNT |
45° SKEW | FIELD SLOPE AND SKEW |
ADJUSTABLE HEIGHT |
VARIABLE PITCH |
|---|---|---|---|---|---|---|
| BCI 400 (Joist Width = 1 1/2") | ||||||
9 1/2" |
ITT29.5 |
IUT29 |
SUR/L210 |
LSSU28 |
THAI222 |
VPA2 |
11 7/8" |
ITT211.88 |
IUT211 |
LSSU210 |
|||
14" |
ITT214 |
IUT211 |
||||
| BCI 450 (Joist Width = 1 3/4") | ||||||
9 1/2" |
ITT9.5 |
IUT9 |
SURI/LI9 |
LSSUI25 |
THAI1.81/22 |
VPA25 |
11 7/8" |
ITT11.88 |
IUT11 |
SURI/L11 |
|||
14" |
ITT14 |
IUT14 |
||||
16" |
ITT16 |
IUT14 |
LSSUI255 |
- |
||
| BCI 600 (Joist Width = 2 5/16") | ||||||
11 7/8" |
ITT3511.88 |
IUT3512 |
SURI/LI3510/12 |
LSSUI35 |
THAI3522 |
VPA25 |
14" |
ITT3514 |
IUT3514 |
SURI/L13514/20 |
|||
16" |
MIT3516 |
MIU2.37/16 |
LSSUI355 |
- |
||
18" |
MIT3518 |
MIU2.37/18 |
- |
|||
20" |
MIT3520 |
MIU2.37/20 |
- |
|||
1. Joist end reactions may exceed hanger
capacity. The combination of joist capacity, header material and fasteners should be
checked by a qualified designer to ensure proper hanger selection. Refer to the current
Simpson Strong-Tie® Connectors for use with Composite Wood Products catalog for
additional information.
2. Install nail through tab of ITT and IUTT hangers at approx. 30 degree
angle to prevent bottoming out on hanger seat.
3. Shaded hangers require web stiffeners at joist ends.
4. LSU3510-2 is field-sloped only; skewed option must be factory-ordered.
5. Potential joist rotation may occur; see current Simpson Strong-Tie® Connectors for Use with
Composite Wood Products for information on rotation resistance.
6. THAI-2 must be factory-ordered for hanger width needed.
DOUBLE BCI JOISTS
| JOIST HEIGHT |
TOP FLANGE |
FACE MOUNT |
45° SKEW | FIELD SLOPE AND SKEW |
ADJUSTABLE HEIGHT |
|---|---|---|---|---|---|
| BCI 400 (Joist Width = 1 1/2") | |||||
9 1/2" |
MIT29.5-2 |
MIU29.2 |
SUR/L210-2 |
LSSU210-2 |
THAI-26 |
11 7/8" |
MIT211.88-2 |
MIU2mn1-2 |
|||
14" |
LBV214-2 |
MIU211-2 |
|||
| BCI 450 (Joist Width = 1 3/4") | |||||
9 1/2" |
MIT49.5 |
MIU49 |
SUR/L410 |
LSSU410 |
THAI422 |
11 7/8" |
MIT411.88 |
MIU411 |
|||
14" |
MIT414 |
MIU414 |
SUR/L414 |
||
16" |
MIT416 |
MIU416 |
LSSU4105 |
... |
|
| BCI 600 (Joist Width = 2 5/16") | |||||
11 7/8" |
MIT3511.88-2 |
MIU4.75/11 |
- |
LSSU3510-24 |
THAI-26 |
14" |
MIT3514-2 |
MIU4.75/14 |
- |
||
16" |
WP3516-2 |
MIU4.75/16 |
- |
LSU3510-24,5 |
- |
18" |
WP3518-2 |
MIU4.75/18 |
- |
- |
|
20" |
WP3520-2 |
MIU4.75/20 |
- |
- |
|
SINGLE I-JOIST HARDWARE

| JOIST HEIGHT |
TOP FLANGE |
FACE MOUNT |
TOP FLANGE MASONRY |
45° SKEW | FIELD SLOPE AND SKEW |
ADJUSTABLE STRAP HANGER |
ADJUSTABLE RAFTER TIE |
|---|---|---|---|---|---|---|---|
| BCI 400 SERIES (Joist Width = 1 1/2") | |||||||
9 1/2" |
THO15950 |
THF15925 |
MPH1595 |
SKH1520 |
TMU210 |
MSH222 |
*TMP2 |
11 7/8" |
THO15118 |
THF15112 |
MPH15118 |
SKH1524 |
|||
14" |
THO15140 |
THF15140 |
MPH1514 |
||||
| BCI 450 SERIES (Joist Width = 1 3/4") | |||||||
9 1/2" |
THO17950 |
THF17925 |
MPH1795 |
SKH1720 |
TMU179 |
MSH1722 |
*TMP175 |
11 7/8" |
THO17118 |
THF17112 |
MPH17118 |
SKH1724 |
|||
14" |
THO17140 |
THF17140 |
MPH1714 |
||||
16" |
THO17160 |
THF17157 |
MPH1716 |
||||
| BCI 600 SERIES (Joist Width = 2 5/16") | |||||||
11 7/8" |
THO23118 |
THF23118 |
MPH23118 |
SKH2320 |
TMU23 |
MSH2322 |
*TMP23 |
14" |
THO23140 |
THF23140 |
MPH2314 |
SKH2324 |
|||
16" |
THO23160 |
THF23160 |
MPH2316 |
||||
18" |
THO23180 |
THF23180 |
MPH2318 |
||||
20" |
THO23200 |
THF23180 |
MPH2320 |
||||
DOUBLE I-JOIST HARDWARE
| JOIST HEIGHT |
TOP FLANGE |
FACE MOUNT |
TOP FLANGE MASONRY |
45° SKEW | FIELD SLOPE AND SKEW |
ADJUSTABLE STRAP HANGER |
ADJUSTABLE RAFTER TIE |
|---|---|---|---|---|---|---|---|
| DOUBLE BCI 400 SERIES (JOIST WIDTH = 1 1/2") | |||||||
9 1/2" |
THO15950-2 |
THF15925-2 |
MPH1595-2 |
SKH1520-2 |
TMU31 |
MSH222-2 |
*TMP31 |
11 7/8" |
THO15118-2 |
THF15112-2 |
MPH15118-2 |
SKH1524-2 |
|||
14" |
THO15140-2 |
THF15140-2 |
MPH1514-2 |
||||
| DOUBLE BCI 450 SERIES (JOIST WIDTH = 1 3/4") | |||||||
9 1/2" |
THO17950-2 |
THF17925-2 |
MPH3595 |
SKH410 |
TMU48 |
MSH422 |
*TMP4 |
11 7/8" |
THO17118-2 |
THF17112-2 |
MPH35118 |
||||
14" |
THO17140-2 |
THF17140-2 |
MPH3514 |
SKH414 |
|||
16" |
THO17160-2 |
THF17160-2 |
MPH3516 |
||||
| DOUBLE BCI 600 SERIES (JOIST WIDTH = 2 5/16") | |||||||
11 7/8" |
THO23118-2 |
THF23112-2 |
MPH23118-2 |
- |
- |
- |
- |
14" |
THO23140-2 |
THF23140-2 |
MPH2314-2 |
- |
- |
- |
- |
16" |
THO23160-2 |
THF23160-2 |
MPH2316-2 |
- |
- |
- |
- |
18" |
THO23180-2 |
THF23160-2 |
MPH2318-2 |
- |
- |
- |
- |
20" |
THO23200-2 |
THF23160-2 |
MPH2320-2 |
- |
- |
- |
- |
NOTES
* TMP Series adjusts from 1/12 to 6/12 pitch
** TMPH Series adjusts from 6/12 to 14/12 pitch
Shaded hangers require web stiffeners at joist ends.