30H Series Function Descriptions Page 3
Best Access Systems
| 30H Series Function Descriptions Cont'd | ||||||
Function
& Diag. |
Description |
Outside Lever or Knob |
Inside Knob/Lever |
|||
Latch Operated by |
Deadbolt Operated by |
Locked by |
Unlocked by |
Locked By |
Unlocked by |
|
| Keyless (Continued) | ||||||
| Rotating inside or outside knob/lever | N/A | Cannot be locked | Always unlocked | Cannot be locked | Always unlocked | |
| Available in 34H and 35H series only. | ||||||
| Rotating inside knob/lever | N/A | Always locked | Cannot be unlocked | Cannot be locked | Always unlocked | |
| The latchbolt is deadlocked with an auxiliary deadlatch. Available in 34H and 35H series only. | ||||||
| Electromechanical | ||||||
| Rotating inside knob/lever, OR Rotating outside knob/lever - only when power is off, OR Turning key in outside cylinder. |
N/A | Applying 24 volts AC/DC. Outside knob/lever remains locked only while power is on. | Switching off 24 volts AC/DC. Outside knob/lever remains unlocked only while no power is on. | Cannot be locked | Always unlocked | |
| Powered by 24 volts AC/DC and 0.75 amps, continuous duty. | ||||||
| Rotating inside knob/lever, OR Rotating outside knob/lever - only when power is on, OR Turning key in outside cylinder. |
N/A | Switching off 24 volts AC/DC. Outside knob/lever remains locked only while no power is on. | Applying 24 volts AC/DC. Outside knob/lever remains unlocked only while power is on. | Cannot be locked | Always unlocked | |
| Powered by 24 volts AC/DC and 0.75 amps, continuous duty. | ||||||
| Rotating inside or outside knob/lever -
only when power is off, OR Turning key in inside or outside cylinder. |
N/A | Applying 24 volts AC/DC. Outside knob/lever remains locked only while power is on. | Switching off 24 volts AC/DC Outside knob/lever remains unlocked only while no power is on. | Applying 24 volts AC/DC. Inside knob/lever remains unlocked only while power is on. | Switching off 24 volts AC/DC. Inside knob/lever remains unlocked only while no power is on. | |
| Available in 24 volts AC/DC locks both inside and outside knobs/levers simultaneously. Powered by 0.75 amps, continuous duty. | ||||||
| Rotating inside or outside knob/lever -
only when power is on, OR Turning key in inside or outside cylinder. |
N/A | Switching off 24 volts AC/DC. Outside knob/lever remains locked only while no power is on. | Applying 24 volts AC/DC. Outside knob/lever remains unlocked only while power is on. | Switching off 24 volts AC/DC. Inside knob/lever remains unlocked only while no power is on. | Applying 24 volts AC/DC. Inside knob/lever remains unlocked only while power is on. | |
| Applying 24 volts AC/DC unlocks both inside and outside knobs/levers simultaneously. Powered by 0.75 amps, continuous duty. | ||||||
| Rotating inside knob/lever, OR Rotating outside knob/lever - only when power is off. |
N/A | Applying 24 volts AC/DC. Outside knob/lever remains locked only while power is on. | Switching off 24 volts AC/DC Outside knob/lever remains unlocked only while no power is on. | Cannot be locked | Always locked | |
| Powered by 24 volts AC/DC and 0.75 amps, continuous duty. | ||||||
| Rotating inside knob/lever, OR Rotating outside knob/lever - only when power is on. |
N/A | Switching off 24 volts AC/DC. Outside knob/lever remains locked only while no power is on. | Applying 24 volts AC/DC. Outside knob/lever remains unlocked only while power is on. | Cannot be locked | Always unlocked | |
| Powered by 24 volts AC/DC and 0.75 amps, continuous duty. | ||||||
*ATTENTION: Locksets that secure both sides of the door are controlled by building codes and the Life Safety Code®. In an emergency exit situation, failure to quickly unlock the inside lever could be hazardous or even fatal.