Bradford White Corp.
Complete Residential Water Heater Line
Residential Water Heater Line Page - 6
Complete Residential Water Heater Line
RESIDENTIAL GAS |
ENERGY SAVER MODELS
1" Non-CFC Foam Insulation 76% Recovery Efficiency (except where indicated)
NATURAL GAS |
LP GAS |
A |
B |
C |
D |
E |
Approx. Shipping Weight (Lbs.) |
||||||
Model Number |
Gal. Cap. |
Input BTU |
GPH Rec. 90°F Rise |
Model Number |
Gal. Cap. |
Input BTU |
GPH Rec. 90°F Rise |
||||||
M-I-30T6LN• |
30 |
32,000 |
33 |
M-I-30T6CX• |
30 |
32,000 |
33 |
59 1/4" |
16" |
3" |
503/4"/567/8" |
14" |
102 |
M-I-30S6LN |
30 |
30,000 |
31 |
M-I-30S6CX |
30 |
30,000 |
31 |
48 1/4" |
18" |
3" |
39 3/4" |
14" |
98 |
M-I-403T6LN• |
40 |
40,000 |
41 |
M-I-403T6CX• |
40 |
40,000 |
41 |
61 1/2" |
18" |
3" |
521/2"/585/8" |
14" |
116 |
M-I-403S6LN• |
40 |
40,000 |
41 |
M-I-403S6CX• |
40 |
40,000 |
41 |
51" |
20" |
3" |
42" / 48" |
14" |
122 |
M-I-5036LN• |
50 |
40,000 |
41 |
M-I-5036CX• |
50 |
40,000 |
41 |
60 1/4" |
20" |
3" |
503/4"/567/8" |
14" |
149 |
M-I-50L6LN |
48 |
40,000 |
41 |
M-I-50L6CX |
48 |
40,000 |
41 |
51" |
22" |
3" |
411/2" |
14" |
148 |
M-I-65T6CN• |
65 |
65,000 |
68 |
M-I-65T6CX• |
65 |
65,000 |
68 |
64 1/2" |
22" |
4" |
541/2"/603/4" |
14" |
202 |
M-I-75S6CN* |
75 |
75,000 |
76 |
M-I-75S6CX* |
75 |
75,000 |
76 |
63 3/4" |
24 1/2" |
4" |
53" |
16" |
264 |
M-I-100T6CN** |
100 |
88,000 |
90 |
M-I-100T6CX** |
100 |
88,000 |
90 |
68 11/16" |
28 1/4" |
4" |
59 5/16" |
15 5/8" |
428 |
Water connections 11" o.c. on M-I-75.
Water connections on M-I-100 are 1 1/4" NPT and 16" o.c.
Hand hole cleanout standard on M-I-100 model.
*Equipped with 1 1/4" Non-CFC foam insulation.
**Equipped with 2" Non-CFC foam insulation.
•Models feature optional side/top T&P location. "D" dimension listed as side/top.
M-I-75 and M-I-100 not equipped with Slider Combustion Chamber Door.
For 10 year models, change suffix number from "6" to "10".
All models (except M-I-75 and M-I-100) meet California Energy Commission requirements. For South Coast Air Quality Management District
requirements change "L" or "C" to "S" on natural gas models.
Suitable for Water (Potable) Heating and Space Heating
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to
any existing heating system or component(s) previously used with a non-potable water heating appliance.
ENERGY SAVER MODELS
2" Non-CFC Foam Insulation 78% Recovery Efficiency (Minimum)
NATURAL GAS |
LP GAS |
A |
B |
C |
D |
E |
Approx. Shipping Weight (Lbs.) |
||||||
Model Number |
Gal. Cap. |
Input BTU |
GPH Rec. 90°F Rise* |
Model Number |
Gal. Cap. |
Input BTU |
GPH Rec. 90°F Rise* |
||||||
M-4-30T6LN |
30 |
32,000 |
34 |
M-4-30T6CX |
30 |
32,000 |
34 |
59 1/4" |
18" |
3" |
503/4"/567/8" |
14" |
112 |
M-4-403T6LN |
40 |
36,000 |
40 |
M-4-403T6CX |
40 |
34,000 |
38 |
61 1/2" |
20" |
3" |
521/2"/583/4" |
14" |
129 |
M-4-50S6LN |
50 |
36,000 |
38 |
M-4-50S6CX |
50 |
36,000 |
38 |
60 1/4" |
22" |
3" |
503/4"/567/8" |
14" |
150 |
M-4-75S6CN |
75 |
75,000 |
76 |
M-4-75S6CX |
75 |
75,000 |
76 |
63 3/4" |
26" |
4" |
53" |
16" |
232 |
*Based on manufacturers rated recovery efficiency.
•Models feature optional side/top T&P location. "D" dimension listed as side/top.
Meets C.E.C. Title 24, South Coast Air Quality Management District and all other district requirements.
For 10 year models, change suffix from "6" to "10".
Note: Natural gas models standard with aluminized steel "L" burner (except 75 gallon model).
Models with "L" burner do not meet California Air Quality Requirements.
Substitute "S" for the "L" in model number to meet California Air Quality Requirements.
Suitable for Water (Potable) Heating and Space Heating
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
General: All gas water heaters are certified at 300 PSI test pressure and 150 PSI working pressure. All gas connections are 1/2". |