  Bradford White Corp.   Complete Residential Water Heater Line  

Residential Water Heater Line Page - 7

   

Complete Residential Water Heater Line

TTW® SERIES WATER HEATERS

 

STANDARD FEATURES OF THE TTW1 & TTW2

Vitraglas Lining - This exclusive glass formulation is applied under pressure to completely cover the tank interior for years of extra service. Protects against rust and corrosion. Will not crack or peel.

Protective Magnesium Rod - Inhibits corrosion of tank interior for long trouble-free service.

Hydrojet Total Performance System - Helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up at top of tank.

Factory Installed Dielectric Waterway Fittings - All heaters equipped with special water heater nipples for longer life. No special dielectric fittings to buy.

Non-CFC Foam Insulation - Covers the sides and top of tank to save fuel by retarding heat loss. Also, increases jacket rigidity. TTW1 models have 1" Non-CFC Foam - TTW2 models have 2" Non-CFC Foam. (Except on 65 gallon model Non-CFC Foam is 1")

T&P Relief Valve Opening - All sizes have special tapping on side of tank for ease of installing relief valves.

Flue Baffle - Designed to maximize the amount of heat absorbed in the lower portion of tank. Reduces air movement in the water heater during standby periods to retard heat loss up the flue.

Heavy Gauge Steel - Automatically formed, rolled and welded to assure a continuous seam for glass lining.

Six or Ten Year Limited Warranty on Heavy Steel Tank.

Two Year limited Warranty on Parts.

Design Certified by AGA.

Solid brass drain valve. 

(Meet or exceed ASHRAE 90.1b 1992 Standards). Meets C.E.C. Requirements.

NATURAL GAS

LP GAS

A

Floor to Flue Conn. 

B

Jacket Dia. 

C

Vent Size 

D

Floor to T&P Conn. 

E

Floor to Gas Conn. 

Approx. Shipping Weight (Lbs.)

Model Number

Gal. Cap.

Input BTU

GPH Rec. 90°F Rise*

Model Number

Gal. Cap.

Input BTU

GPH Rec. 90°F Rise*

M-I-TW-40L6LN

38

40,000

43

M-I-TW-40L6CX

38

37,500

40

57 3/4"

20"

2"

40 3/4"

14"

166

M-I-TW-50L6LN

48

40,000

42

M-I-TW-50L6CX

48

37,500

39

58 3/4"

22"

2"

41 3/4"

14"

185

FEATURES OF THE TTW1

Power Vented For Positive Exhaust - The TTW1 uses a specially designed assembly that blows exhaust gases directly out of the building eliminating the need for conventional chimneys or expensive flue systems.

Intermittent Pilot Ignition System - Pilot does not burn while the water heater is in the standby mode.

Horizontal Venting - 2" PVC Vent - Can be vented with 2" PVC for lengths up to 20 feet with (3) 90° elbows. 3" PVC Vent - can be vented with 3" PVC for lengths up to 85 feet with (3) 90° elbows. Each 90° elbow is equivalent to 5 feet of pipe length.

Vertical Venting Through Roof - Can be vented through the roof at a vertical height of 20 feet with (3) 90° elbows when using 2" PVC and 40 feet with (3) 90° elbows when using 3" PVC.

Fully Automatic Controls - Automatic temperature selection. Built-in energy cut-off switch prevents abnormally high water temperature for extra safety. Combination gas valve has built-in gas pressure regulation.

*Based on manufacturers rated recovery rates. 

(Meet or exceed ASHRAE 90.1b 1992 Standards). Meets C.E.C. Requirements.

NATURAL GAS

LP GAS

A

Floor to Flue Conn. 

B

Jacket Dia. 

C

Vent Size 

D

Floor to T&P Conn. 

E

Floor to Gas Conn. 

F

Fl. to Space Heating Return 

G

Fl. to Space Heating Outlet 

Approx. Shipping Weight (Lbs.)

Model Number

Gal. Cap.

Input BTU

GPH Rec. 90°F Rise

Model Number

Gal. Cap.

Input BTU

GPH Rec. 90°F Rise

M-II-TW-50T6LN

48

65,000

69

M-II-TW-50T6CX

48

63,000

67

66 7/8"

22"

3"

48 7/8"

16 5/8"

14 1/4"

48 7/8"

188

M-II-TW-65T6CN

65

65,000

70

M-II-TW-65T6CX

65

65,000

70

72 1/16"

22"

3"

54 1/2"

17 1/8"

17 1/2"

54 1/2"

222

M-II-TW-75T6CN

75

75,000

81

M-II-TW-75T6CX

75

73,000

79

71 5/8"

26"

3"

53"

19"

16 3/4"

53"

277

FEATURES OF THE TTW2

Power Vented For Positive Exhaust - The TTW2 uses a specially designed assembly that blows exhaust gases directly out of the building eliminating the need for conventional chimneys or expensive flue systems.

Electronic Ignition System - Pilot does not burn while the water heater is in the standby mode.

Side Connections - For space heating.

Vertical and Horizontal Venting - 3" PVC Vent - Can be vented with 3" PVC for lengths up to 30 feet with (3) 90° elbows. 4" PVC Vent - Can be vented with 4" PVC for lengths up to 60 feet with (3) 90° elbows.

Schedule 40 ABS and CPVC are also approved products for venting.

Each 90° elbow is equivalent to 5 feet

Fully Automated Controls - Fast acting surface mount thermostat for automatic temperature selection. Built-in energy cut-off switch prevents abnormally high water temperature for extra safety. Combination gas valve has built-in gas pressure regulation.

Suitable for Water (Potable) Heating and Space Heating
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.



Request for Information / Request a Catalog from Bradford White Corp.
 
 
 
To request more information from Bradford White Corp., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.