PLUMBING FIXTURES
TECHNICAL DATA


Corner Washfountain Rough-In Dimensions (continued)

Rough-In Notes:

  1. All pipes and fittings not furnished by Bradley are shown in broken lines.
  2. Supply lines for one to two washfountains should be 1"; for three washfountains 1-1/4"; for more than three washfountains, pipe sizes should be increased proportionately.
  3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube.
  4. Check valve inlets are 1/2" IPS.
  5. Dimensions shown in parentheses are millimeters.
  6. For maximum rigidity of sprayhead/support tube assembly, use 1-1/2" IPS galvanized pipe for vent. Use of plastic or copper for vent is not recommended.

Bradley Corporation reserves the right to make changes in design and material without formal notice and without incurring obligation. Verify all rough-in dimensions prior to installation.