CCW-5013-HD
HEAVY DUTY PEDESTRIAN TRAFFIC DECK SYSTEM |
DESCRIPTION
The CCW-5013-HD Deck Coating System is a liquid-applied,
abrasion resistant waterproofing system suitable for surfaces subject to heavy pedestrian
traffic. It consists of three polyurethane components, each designed to provide specific,
long lasting properties, that together form a system with optimum performance. The top
coat is available in nine fade-resistant colors.
TYPICAL USE
The CCW-5013-HD System is applied to concrete decks to
prevent water from entering occupied space below, protect the surface to which it is
applied from damage by water and salts and provide a slip-resistant, attractive
wearing surface.
LIMITATIONS
- Do not apply primer or coatings to a frosty, damp or wet
surface.
- Do not proceed with coating application if temperature is
below 40ºF or if rain is imminent within 8 hours after application.
- If metal pan is used for concrete form, the pan must be
vented. Not for use on grade.
- If deck has a between slab membrane, consult with
manufacturer's representative.
PACKAGING
CCW-501 Base Coat, CCW-502 Intermediate Coat and CCW-503
Top Coat: 5 gallon pails and 55 gallon drums.
CCW-501-T Detail Coat: 5 gallon pails
CCW-557 Primer:
2 gallon units=1 gal. Part A+1 gal. Part B
10 gallon units= 5 gal. Part A+5 gal. Part B
APPLICABLE STANDARDS
ASTM C 957-81
Complies with VOC regulations including SCAQMD 1113.
UL-790 Class A
TOP COAT COLORS
Standard colors are: Stone Gray, Desert Tan, Brick Red,
Evergreen, Colonial Gray, Beige and Clear. Nutmeg, Brown, Pacific Blue, White and Custom
colors are available by special order.
WARNINGS AND HAZARDS
Before use refer to MSDS for important
warnings and safety information. Use only in areas with adequate ventilation.
Avoid breathing vapors. Keep away from heat and flame. Avoid contact with eyes and skin.
In the event of skin contact, remove immediately and wash with warm, soapy water. Wear eye
protection. Always wash hands before eating.
TYPICAL PROPERTIES
CCW-501 BASE COAT
| Solids
Content |
ASTM D 1335 |
85% |
| Hardness,
Shore A |
ASTM D 2240 |
63 |
| Tensile
Strength |
ASTM D 412 |
900 psi |
| Ultimate
Elongation |
ASTM D 412 |
625% |
| Tear
Resistance, Die C |
ASTM D 624 |
150 lb/in |
| Adhesion
to Concrete |
ASTM D-903 |
30PLI |
| Low
Temp. Flexibility |
ASTM D-522 |
-65ºF |
CCW-502 TOP COAT
| Solids
Content |
ASTM D 1335 |
80% |
| Hardness,
Shore A |
ASTM D 2240 |
85 |
| Tensile
Strength |
ASTM D 412 |
2500 psi |
| Ultimate
Elongation |
ASTM D 412 |
450% |
| Tear,
Die C |
ASTM D 624 |
300 lb/in |
| Low
Temp. Flexibility |
ASTM D-522 |
-65ºF |
CCW-503 TOP COAT
| Solids
Content |
ASTM D 1335 |
72% |
| Hardness,
Shore A |
ASTM D 2240 |
94 |
| Tensile
Strength |
ASTM D 412 |
4000 psi |
| Ultimate
Elongation |
ASTM D 412 |
200% |
| Tear,
Die C |
ASTM D 624 |
300 lb/in |
| Low
Temp Flexibility |
ASTM D-522 |
-50ºF |
| Weather
resistance |
ASTM D 882 |
No chalking @ 2000
hrs |
| Abrasion
resistance(system) |
ASTM
C 501 |
<50 mg. |
| Water
Permeability (system) |
ASTM
E 96 (B) |
<1.0 perms |
|