architecture - engineering - construction
AECinfo.com
Printable version Bookmark this page Notify a colleague or friend about this page Bookmark and Share
  Carlisle Coating & Waterproofing   Carlisle Coatings  

Carlisle Coatings - Page 4

   

Carlisle Coatings

CCW-5013-HD

HEAVY DUTY PEDESTRIAN TRAFFIC DECK SYSTEM

DESCRIPTION

The CCW-5013-HD Deck Coating System is a liquid-applied, abrasion resistant waterproofing system suitable for surfaces subject to heavy pedestrian traffic. It consists of three polyurethane components, each designed to provide specific, long lasting properties, that together form a system with optimum performance. The top coat is available in nine fade-resistant colors.

TYPICAL USE

The CCW-5013-HD System is applied to concrete decks to prevent water from entering occupied space below, protect the surface to which it is applied from damage by  water and salts and provide a slip-resistant, attractive wearing surface.

LIMITATIONS

  • Do not apply primer or coatings to a frosty, damp or wet surface.
  • Do not proceed with coating application if temperature is below 40ºF or if rain is imminent within 8 hours after application.
  • If metal pan is used for concrete form, the pan must be vented. Not for use on grade.
  • If deck has a between slab membrane, consult with manufacturer's representative.

PACKAGING

CCW-501 Base Coat, CCW-502 Intermediate Coat and CCW-503 Top Coat: 5 gallon pails and 55 gallon drums.

CCW-501-T Detail Coat: 5 gallon pails

CCW-557 Primer:

2 gallon units=1 gal. Part A+1 gal. Part B

10 gallon units= 5 gal. Part A+5 gal. Part B

APPLICABLE STANDARDS

ASTM C 957-81

Complies with VOC regulations including SCAQMD 1113.

UL-790 Class A

TOP COAT COLORS

Standard colors are: Stone Gray, Desert Tan, Brick Red, Evergreen, Colonial Gray, Beige and Clear. Nutmeg, Brown, Pacific Blue, White and Custom colors are available by special order.

WARNINGS AND HAZARDS

Before use refer to MSDS for important warnings and safety information. Use only in areas with adequate ventilation. Avoid breathing vapors. Keep away from heat and flame. Avoid contact with eyes and skin. In the event of skin contact, remove immediately and wash with warm, soapy water. Wear eye protection. Always wash hands before eating.

TYPICAL PROPERTIES

CCW-501 BASE COAT

Solids Content ASTM D 1335 85%
Hardness, Shore A ASTM D 2240 63
Tensile Strength ASTM D 412 900 psi
Ultimate Elongation ASTM D 412 625%
Tear Resistance, Die C ASTM D 624 150 lb/in
Adhesion to Concrete ASTM D-903 30PLI
Low Temp. Flexibility ASTM D-522 -65ºF

CCW-502 TOP COAT

Solids Content ASTM D 1335 80%
Hardness, Shore A ASTM D 2240 85
Tensile Strength ASTM D 412 2500 psi
Ultimate Elongation ASTM D 412 450%
Tear, Die C ASTM D 624 300 lb/in
Low Temp. Flexibility ASTM D-522 -65ºF

CCW-503 TOP COAT

Solids Content ASTM D 1335 72%
Hardness, Shore A ASTM D 2240 94
Tensile Strength ASTM D 412 4000 psi
Ultimate Elongation ASTM D 412 200%
Tear, Die C ASTM D 624 300 lb/in
Low Temp Flexibility ASTM D-522 -50ºF
Weather resistance ASTM D 882 No chalking @ 2000 hrs
Abrasion resistance(system) ASTM C 501 <50 mg.
Water Permeability (system) ASTM E 96 (B) <1.0 perms

 



Request for Information / Request a Catalog from Carlisle Coating & Waterproofing
 
 
 
To request more information from Carlisle Coating & Waterproofing, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.