| Celestial UL LISTED
TRANSFORMERS, CONTROLLERS, DIMMER
1 CLASS II TRANSFORMERS:
| WATTAGE |
DIMENSION |
PRIMARY |
SECONDARY |
WEIGHT |
| 40VA |
2-1/4" x 2-1/4" x
2-1/4" |
120V |
24V |
1-1/2 LBS. |
| 60VA |
5-1/4" x 3\" x
3-1/4" |
120V |
12V |
3 LBS. |
PLUG-IN TRANSFORMER
Our custom-made 60VA transformer has a resettable 5 amp
Breaker and is housed in a galvanized sheet enclosure, Class II UL listed.
2 NON-CLASS II TRANSFORMERS:
UL LISTED for indoor and outdoor use.
Larger Transformer are
available upon request.
| WATTAGE
|
DIMENSION
|
PRIMARY |
SECONDARY |
WEIGHT
|
| Height |
Width |
Depth |
| 50VA |
6.41 |
3.14 |
3.05 |
120/240V |
12/24V |
4 LBS. |
| 100VA |
7.16 |
3.89 |
3.67 |
120/240V |
12/24V |
5 LBS. |
| 150VA |
7.16 |
3.89 |
3.67 |
120/240V |
12/24V |
7 LBS. |
| 250VA |
8.68 |
4.08 |
3.67 |
120/240V |
12/24V |
10 LBS. |
| 500VA |
9.06 |
4.37 |
3.98 |
120/240V |
12/24V |
15 LBS. |
| 750VA |
9.68 |
4.75 |
4.30 |
120/240V |
12/24V |
19 LBS. |
| 1000VA |
10.50 |
5.50 |
4.92 |
120/240V |
12/24V |
23 LBS. |
| 1500VA |
11.62 |
5.50 |
4.92 |
120/240V |
12/24V |
32 LBS. |
| 2000VA |
13.00 |
5.50 |
5.13 |
120/240V |
12/24V |
38 LBS. |
| 3000VA |
11.50 |
10.31 |
7.13 |
120/240V |
12/24V |
55 LBS. |
- Non-Class II transformer do not have an inherent
current limiting. Therefore, secondary circuit protection must be provided at the
time of installation. Under NEC Code, secondary circuit must be fused for every 5 amps on
a 12 volt system and every 4 amps on a 24 volt system.
- Primary fusing for Class I installation available
upon request at the cost of $90 per transformer.
- Our transformers are potted to reduce vibration and
minimize noise.
- Out transformers are fully insulated and no
clearance, vertical and horizontal, is required on installation.
3 MOISTURE PROOFED TRANSFORMER NEMA 3R
ENCLOSURES FOR OUTDOOR USE:
| PART NO. |
DIMENSION |
TRANSFORMER |
WEIGHT |
| 464RTSC |
4" x 6" x 4" |
TF60 |
3 LBS. |
|