- Painting or wallpapering over a surface
coated with Radiance Low-e Ceiling Finish will eliminate the heat
reflecting properties.
- Greatest energy savings are achieved when
all walls and ceilings inside the structure are coated with Radiance Low-e Ceiling Finish.
TECHNICAL DATA
| Viscosity |
ASTM
D562 |
KU |
|
|
Initial |
|
|
102 |
|
Freeze-Thaw |
|
|
141+ |
|
Change |
|
|
39+ |
| Freeze-Thaw
Stability |
ASTM
D2243 |
Cycles |
5 |
| Tensile Strength |
ASTM
D2370 |
psi |
120 |
| Elongation |
ASTM
D2370 |
% |
<10 |
| Hardness |
ASTM
D3363 |
|
|
|
Glass |
|
Pencil |
<6B |
|
Concrete |
|
Pencil |
<6B |
| Adhesion |
ASTM
D3359 |
|
|
|
To Concrete |
|
Rating |
5A |
| |
|
% |
100 |
| Water Vapor |
ASTM
D1653 |
|
|
| Permeability |
|
|
|
|
Water Vapor Transmission |
|
Rate |
|
|
Grains per ft2 per hour |
|
6.5 |
|
Grams per m2 per 24 hours |
|
108.8 |
|
Water Vapor Permeance |
|
|
|
Perms |
|
13.3 |
|
Metric Perms |
|
8.7 |
| Water Absorption |
ASTM
D570 |
% |
17.2 |
| Flash Point |
ASTM
D93 |
°F |
>180° |
| Contrast Ratio |
ASTM
D2805 |
|
|
|
2 mil Bird |
|
|
0.954 |
|
3 mil Bird |
|
|
0.990 |
|
4 mil Bird |
|
|
0.994 |
| Reflectance |
ASTM
E1347 |
% |
79.1 |
| "E"
value (emissivity): |
|
|
0.68 |
| Volume solids % |
ASTM
D1259 |
|
60
± 1 |
| Weight
solids % |
ASTM
D1259 |
|
56
± 1 |
| Weight per gallon |
|
|
8.5
± 0.2 |
| Re-coat time |
|
|
24
hours |
ORDER INFORMATION
Packaging
- 1 gallon pails (11.5 lbs. or 3.28 L)
- 5 gallon pails (56.5 lbs. or 18.93 L)
Coverage
- Smooth Surface:
400-500 sq. ft. per gallon
- Textured Drywall:
150-300 sq.ft. per gallon
CAUTION
Radiance Low-E Ceiling Finish contains calcium carbonate, propylene glycol, zinc
sulfide, refined bauxite.
Risks
May cause skin, eye or respiratory
irritation. Ingestion may cause irritation. INTENTIONAL MISUSE BY DELIBERATELY
INHALING THE CONTENTS MAY BE HARMFUL OR FATAL.
Precautions
MAY CAUSE EYE, SKIN OR RESPIRATORY
IRRITATION, KEEP OUT OF THE REACH OR CHILDREN. Avoid contact with skin, eyes and
clothing. Wash thoroughly after handling. Keep container closed when not in use. DO
NOT take internally. Assure good cross ventilation by opening doors and
windows to minimize odor. Use impervious gloves, eye protection. If the TLV is
exceeded or used in a poorly ventilated area, use approved respiratory protection
equipment in accordance with applicable federal, state and local regulations. All label
warnings must be observed until container is commercially cleaned or reconditioned.
Dispose of according to Local, state and federal requirements. Low hazard for recommended
handling.
First Aid
In case of eye contact, flush thoroughly
with water for at least 15 minutes. In case of skin contact, was affected areas with
soap and water. If irritation persists, SEEK MEDICAL ATTENTION. If inhalation
causes physical discomfort, remove to fresh air. If discomfort persists or any
breathing difficulty occurs, or if swallowed, SEEK IMMEDIATE MEDICAL ATTENTION.
Refer to Material Safety Data Sheet
(MSDS) for further information.
VOC Content
121 g/L or 1.01 lbs. of VOS per gallon of
coating, less water and exempt solvents.
For medical emergencies only, call
ChemTrec (1/800/424-9300).
CUSTOMER SATISFACTION GUARANTEE
The manufacturer assures your complete
satisfaction when the product is applied according to the label directions. If this
finish fails to perform, the manufacturer will furnish an equivalent amount of
Radiance at no cost or will refund the purchase. This guarantee does not
include labor or cost of labor for the application of any paint. This guarantee gives
you specific rights and you may also have other rights, which vary from state to state.

ChemRex Inc,
889 Valley Park Drive;
Shakopee, MN 55379; (612) 496-6000
CUSTOMER SERVICE:
(800) 766-6776
www.radiancecomfort.com |