GUARANTEE
The Clearstream System has a two-year limited warranty against defects in material and workmanship from the date of
purchase. The system and/or its components will be repaired or replaced with new or rebuilt equals to the original equipment, if
all installation, operation and maintenance instructions of the manufacturer have been adhered to.
SERVICE
In order for the Clearstream System to function at optimum performance levels, the system will require periodic service. The
recommended service schedule includes:
SERVICE |
|
FREQUENCY |
Repair or replace aerator |
|
2 to 10 years |
Clean filters on aerator |
|
6 months to 2 years |
Break up scum in clarifier |
|
6 months to 2 years |
Pump sludge from aeration tank |
|
2 to 5 years |
Pump sludge from trash trap |
|
2 to 5 years |
Check aeration diffuser |
|
annually |
Check surge control weir |
|
6 months |
For the first two years from the date of purchase, your local installer, from whom you purchased your Clearstream System, will
inspect your system on a routine basis for operational problems. Service on Clearstream electrical and mechanical components
will be performed at no charge, if such components are found to be defective.
After the termination of the guaranteed service period, your local installer will make available a service policy for a nominal
annual fee.
TO PREVENT MALFUNCTIONS OF YOUR SEWAGE SYSTEM, THE FOLLOWING GUIDELINES SHOULD BE
FOLLOWED:
Any sewage treatment system, whether aerobic or septic, should not have inorganic materials (plastics, cigarette butts,
condoms, throwaway diapers, etc.), which the bacteria cannot consume, discharged into the system.
Large amounts of harsh chemicals, oil, grease, high sudsing detergents, discharge from water softeners, disinfectants or
any other chemical or substance that kills bacteria should not be discharged into the system. Garbage disposals are not
recommended.
Excessive use of water, over the design flow of the system, will cause the system not to perform to its fullest capabilities.
The proper operation of this or any other home sewage system depends upon proper organic loading and the life of the
micro-organisms inside the system. Clearstream is not responsible for the in-field operation of a system, other than the
mechanical and structural workings of the plant itself. We cannot control the amount of harsh chemicals or other harmful
substances that may be discharged into the system by the occupants of a household. We can only provide a
comprehensive owner's manual that outlines most substances that should be kept out of the system.
MODEL |
|
SERVES UP TO |
|
RATED |
Model 500N |
|
5 Residents @ 100 G.P.P |
|
500 G.P.D. |
Model 600N |
|
6 Residents @ 100 G.P.P |
|
600 G.P.D. |
Model 750N |
|
7.5 Residents @ 100 G.P.P |
|
750 G.P.D. |
Model 1000N |
|
10 Residents @ 100 G.P.P |
|
1000 G.P.D. |
Model 1500N |
|
15 Residents @ 100 G.P.P |
|
1500 G.P.D. |