Royal Anchor Systems, Inc. HDPE Manhole Adjusting Rings HDPE Manhole Adjusting Rings Page - 2
 |
WARRANTY
The LadTech Promise
A Full Two Year Limited Warranty |
LadTech, Inc. warrants the adjusting ring for two years against defects in materials in the adjusting ring from the
date of installation. LadTech shall replace any defective adjusting ring for two (2) years from the date of
installation upon receipt of prior approval from LadTech, Inc. Calls to obtain prior approval to replace a defective
adjusting ring shall be made to 1-612-415-1252. This Limited Warranty covers adjusting ring defects in
materials only. It does not cover incidental or consequential damages. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation may not apply to you. This Warranty
gives you specific rights, and you may have other rights which vary from state to state.
Dwight Wiedrich
President, LadTech, Inc. |
POLYETHYLENE MANHOLE ADJUSTING RINGS INSTALLATION INSTRUCTIONS
- Clean the concrete cone or top slab with a whisk broom or chisel to obtain a flat seating surface, eliminating all rocks, gravel, blacktop,
protruding concrete or frozen debris.
- Apply an approved sealant tot he first HDPE ring. Place the sealant 360 degrees on the flat side of the ring, as close as possible to the
male lip. (A second application of sealant can be applied between the first sealant and the holes, helping the first ring to seat level if
surface irregularites are present).
- Place the ring male lip down, inside the cone or top slab opening.***
- Place sealant around the second ring on the flat side, as close to the male lip as possible, being careful to cover the entire 360 degrees
of the ring. Install the second ring on top of the first, compressing the sealant by standing on the rings.
- Continue step 4 using 4", 2", 1-1/2", 1-1/4", and 3/4" x 1-1/2" sloped rings as required for each manhole to obtain a height difference of
1/4" of grade after the casting is installed.
- Prior to placing the casting, install an approved sealant to the top of the last ring so the sealant is between the casting and the flat
portion of the top ring (all 360 degrees).
- When directed by the engineer, wrap filter fabric around the top 1 to 2 inches of the concrete cone, the entire height of the rings, and the
casting flange. Overlap the flange approximately 4 to 6 inches, (usually an 18" width of fabric is sufficient). Place dirt around fabric as
necessary to hold in place.
***If the cone or top slab is eccentric, and does not allow the ring to seat flush, use a wood saw to cut a portion (usually 90-120 degrees
is sufficient) of the male lip off until the ring can sit flush on the concrete.