Fire Labelling Guide - Fire Door Frames
Fire Labelling Guide - Hollow Metal Fire Doors Why Choose W.C.G.S. Engineered to provide excellent paint adherence with no
special pre-painting treatment, wipe coat galvanized steel producers recommend that primer
painting not be used as it only encourages moisture entrapment. ASTM Test Procedure D-1735: Test results above wereconductedin standard humidity cabinet at 100% relative humidity at 100F The products were not specially treated in any way. They were scored through to bare steel and exposed in accordance with ASTM test procedure D1735 The complete failure of the electro galvanized sample in dramatic contrast to the virtually compared wipe coat galvanized steel. Conclusive results above clearly indicate the superior corrosion resistance of wipe coat galvanized steel. Wipe Coat Galvanized Steel Salt - Fog Test on Painted Panels: In this test ASTM-B117
panels were subjected to a 5% NcCl non acidualted salt spray at 95F The pre treatment used
was a zinc phosphate and the paint was a two coat baked system with a modified silicone
alkyd top coat (10 mil total paint thickness). Even with a first class paint system
underfilm corrosion occurs on electro-galvanized steel much earlier than on wipe coat
galvanized steel.
|