   Dual-Lite  Dual-Lite Products  

Dual-Lite Lite Forms - Page 16

 

 

Product Selector
AC
Model
Numbers
Emergency
Model
Numbers
Colors  

   
Description

Exit
Letters
  
Housing
Stencil
Face(s)
LCSRW LCSRWE Red White White Single face with canopy
LCSGW LCSGWE Green White White Single face with canopy
LCSRB LCSRBE Red Black Black Single face with canopy
LCSGB LCSGBE Green Black Black Single face with canopy
LCSRBN LCSRBNE Red Black Brushed Single face with canopy
LCSGBN LCSGBNE Green Black Brushed Single face with canopy
LCDRW LCDRWE Red White White Double face with canopy
LCDGW LCDGWE Green White White Double face with canopy
LCDRB LCDRBE Red Black Black Double face with canopy
LCDGB LCDGBE Green Black Black Double face with canopy
LCDRBN LCDRBNE Red Black Brushed Double face with canopy
LCDGBN LCDGBNE Green Black Brushed Double face with canopy

Options and Accessory items

   
Description
Factory Equipped Add Suffix To Model Field Conversion Kit Order Part Number
Spectron self-testing/self-diagnostic electronics(2)(3) I -
Emergency operation module - (1) FC-E
Spectron emergency operation module - FC-EI
2-circuit operation(4)(9) -2C -
Fire alarm panel interface(5)(8)(9) -FAP -
Flasher module(2)(8) -FM -
Audible/Flasher module(2)(8) -AF -
Remote DC operation(4)(7)(8) -DC -
220/240 VAC, 50 Hz operation -24K -
Tamper-resistant option -TR -
Vandal-resistant shield(6) -VR -
Wall mount only (less canopy) -XC -
Pendant mounting kit (white) - PMLCW
Pendant mounting kit (black) - PMLCB
Wire guard (Wall mount) - WGLX
Wire guard (Ceiling mount) - WGLXC
Wire guard (End mount) - WGLXE

(1) For factory equipped emergency models, see Product Selector above.
(2) For specification with emergency models only.
(3) Add "
I" option suffix immediately after base model number. Example: LCSRWEI
(4) For use with AC models only.
(5) Operates with 24-volt AC or DC fire alarm panels.
(6) Includes - TR option tamper-proof screws to prevent unauthorized access to internal electrical components.
(7) For emergency illumination of sign from remote 6-24 VDC power sources.
(8) -FAP, -FM, -AF or -DC options may not be specified together.
(9) -2C and -FAP options may be specified together.

Warranty

Liteforms Collection, LC Series LED Exit Signs are guaranteed by the manufacturer under normal and proper use, against defects in material and workmanship under the following schedule:
Item Warranty Period
LED Illumination Strip Lifetime
Unit and Electronics 5 Years Full
Batteries provided in emergency models 3 Years Full Plus
3 Years Pro-Rata

Correction of all defects shall be by replacement or repair (at Dual-Lite's option) and shall constitute fulfillment of all of the manufacturer's obligations.

 

Dimensions

Suggested Specifications

Exit sign construction will be high-strength cast aluminum in textured (white) (black) (black with brushed face) finish. Exit face will provide 6" high letters with ¾" stroke and snapout, replaceable chevron type directional arrows. Exit sign design will allow universal 120/277VAC, 60 Hz operation. Normal AC illumination will be provided by (12 red) (6 green) high-output LEDs consunimg less than 1 watt at 120 or 277 VAC. Normal LED lamp life will be in excess of 20 years. Exit letters will provide twice the lumen output and 10 times the illumination uniformity required by 1998 UL specifications. Exits will be (single face) (double face) and provided with all necessary components for wall, ceiling or end mounting applications. Mounting canopies will be provided with all models and will be of identical construction and color to match the exit frame. Exits will be designed to mount to 3½" or 4" octagon, 4" square or standard plaster rings. Emergency exit models will be achieved through a (factory) (field) installed fully automatic emergency operation module. All emergency module components will mount inside the exit housing and will include a solid-state, constant current type battery charger; a maintenance-free, nickel-cadmium battery; an AC-On indicator light; and a test switch. The unit charger will be capable of recharging the battery within acceptable UL time standards. The emergency operation module must be capable of providing a minimum of 2 hours of emergency operation. Exit signs must comply with all UL 924, (UL Damp Location) and NFPA 101 Life Safety Code requirements.

Optional equipment will include: ________________
Dimensions to be 9¼" (23.5 cm) high x 13-1/8"
(33 cm) wide by 1¾" (4.4 cm) deep.


Distributed By:
90 Fieldstone Court
Cheshire, CT 06410-1212
Tel: (203) 699-3000
Fax: (203) 699-3011
Web Site: www.dual-lite.com

 

 

Request for Information / Request a Catalog from Dual-Lite
 
 
 
To request more information from Dual-Lite, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com