| THRU - THE - WALL AIR
CONDITIONER SPECIFICATIONS |
COOLING PERFORMANCE
| Model |
Cooling Capcity BTU/Hr.-AHAM |
Electric
Characteristics (60 Hertz)
|
| Volts |
Amps AHAM |
Watts |
| COOLING ONLY |
|
|
|
|
| WSO7A10D |
7000 |
115 |
6.7 |
735 |
| WSO9A10D |
9000 |
115 |
9.0 |
980 |
| WS12A10D |
11500 |
115 |
11.5 |
1280 |
| WSO9A30D |
9000/8800 |
230/208 |
4.5/4.9 |
980/980 |
| WS12A30D |
11500/11300 |
230/208 |
5.7/6.3 |
1280/1255 |
| WS13A30D |
12500/12300 |
230/208 |
6.3/6.8 |
1435/1415 |
| HEAT PUMPS |
|
|
|
|
| WY09A33D Cool: |
9000/8800 |
230/208 |
4.5/4.8 |
1000/980 |
| WY12A33E Cool: |
11300/10900 |
230/208 |
5.8/6.2 |
1315/1280 |
| ELECTRIC HEAT |
|
|
|
|
| WEO9A33D Cool: Heat: |
9000/8800 11300/10900 |
230/208 |
4.5/4.9 16.0/14.7 |
980/980 3550/2950 |
| WE12A33D Cool: Heat: |
11500/11300 11000/9100 |
230/208 |
5.7/6.3 16.0/14.7 |
1280/1255 3550/2950 |
| WE13A33D Cool: Heat: |
12500/12300 11000/9100 |
230/208 |
6.3/6.8 16.0/14.7 |
1435/1415 3550/2950 |
| Model |
EER-Energy
Efficiency Ratio AHAM |
Moisture
Removal Pints/Hr. |
Air
Circulation CFM |
Chassis
Shipping Weight Lbs. |
| COOLING ONLY |
|
|
|
|
| WSO7A10D |
9.5 |
1.4 |
260 |
93 |
| WSO9A10D |
9.2 |
2.1 |
260 |
103 |
| WS12A10D |
9.0 |
2.9 |
290 |
112 |
| WSO9A30D |
9.2/9.0 |
2.1 |
260 |
101 |
| WS12A30D |
9.0/9.0 |
2.9 |
290 |
109 |
| WS13A30D |
8.7/8.7 |
4.0 |
250 |
119 |
| HEAT PUMPS |
|
|
|
|
| WY09A33D Cool: |
9.0/9.0 |
2.1 |
270 |
107 |
| WY12A33E Cool: |
8.6/8.5 |
2.9 |
290 |
116 |
| ELECTRIC HEAT |
|
|
|
|
| WEO9A33D Cool: Heat: |
9.2/9.0 |
2.1 |
260 |
103 |
| WE12A33D Cool: Heat: |
9.0/9.0 |
2.9 |
290 |
111 |
| WE13A33D Cool: Heat: |
8.7/8.7 |
4.0 |
250 |
121 |
HEAT PUMP --- HEATING PERFORMANCE
| Model |
|
BTU/Hr. |
| WY09A33D |
AHAM certified @ 47º F
outdoor ambient |
8200/8200 |
| Below 47º F ambient |
11000/9100 |
| WY12A33E |
AHAM certified @ 47º F
outdoor ambient. |
10800/10500 |
| Below 47º F ambient |
11000/9100 |
| Model |
Watts |
Amps |
C.O.P. |
EER |
| WY09A33D |
870/840 |
4.1/4.2 |
2.8/2.8 |
9.4/9.8 |
|
3550/2950 |
16.0/14.7 |
|
|
| WY12A33E |
1200/1165 |
5.4/5.7 |
2.6/2.6 |
9.0/9.0 |
|
3550/2950 |
16.0/14.7 |
|
|
Calculate the heat loss of the space to be heated. As long as
the heat loss does not exceed the resistance heating capacity rating of the unit, the
heating performance will be satisfactory.
Change-over from heat pump operation to resistance operation
on models indicate is automatic at a preset outside temperature as shown in the table.
If condensate disposal is desired, an optional drain kit is
available.
DEFROST CONTROL: Temperature indicated (below 20º F at
outdoor coil) and temperature terminated at 43º F. During defrost the compressor stops
and the electric heat starts, then operates with the fan to maintain indoor comfort. Below
43º F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens in indoor base pan
for defrost condensate disposal.
INSTALLATION INFORMATION FOR WSC SLEEVE
| Sleeve
Dimensions |
Finished
Hole |
| Height |
Width |
Depth Overall |
Overall Depth Sleeve
w/front |
Height |
Width |
| 16¾" |
27" |
16¾" |
23" |
17¼" |
27¼" |
INSTALLATION INFORMATION FOR WSC SLEEVE
| Minimum Extension into
room w/front |
Minimum Outside
Extension |
| 7½" |
9/16" |
NOTE: Sleeve must be mounted a minimum of 3½" from the floor
and a minimum of 24" below ceiling. See installation instructions No. 920-007-02.
PLUG FACE--- NEMA #

Supply Cord - All with Right Angle Plug 6' on 115V; 5' on 230/208V |