| ITEM |
DESCRIPTION |
MODEL
NO. |
| WALL
SLEEVE |
G-90
zinc-coated steel is prepared in an eleven step process, then electrostatically coated
with a polyester finish and cured in an oven for exceptional durability. The wall sleeve
is insulated for thermal efficiency. |
TAX99WB |
| DEEP
WALL SLEEVE EXTENSION |
A 4
in. deep, anodized aluminum extension that attaches to the rear of the wall sleeve when
the wall is greater than 11 in. thick ( 9-½in. when a subbase is used. 10 in. when a
lateral duct is used). |
TAX04WE |
|
Standard,
stamped, aluminum-anodized to resist chalking and oxidation. |
TAX99GA |
| OUTDOOR
LOUVERS |
Architectural
grilles that consist of heavy gauge 6063-T5 aluminum alloy: - Clear anodized aluminum. -
Dark bronze acrylic enamel. |
TAXAA42
TAXDB42 |
| CONDENSATE
DRAIN KIT |
Attaches
to the bottom of the wall sleeve, for internal draining of condensate or to the rear wall
sleeve flange for external draining. Packed in quantities of ten. |
TAX99DR10 |
| CONTROL DOOR LOCK |
Lock, with 2 keys,
installs quickly to restrict access to unit controls. |
TAX99DL |
| DECORATIVE SUBBASE |
Provides unit support
for walls less than 4 in. thick. Includes leveling legs, side filler panels and mounting
bracket for accessory electrical receptacle. Accepts circuit breaker, power disconnect
switch, conduit kit or electrical receptacle. |
TAX99SB |
| CONDENSER BAFFLE KIT |
Air baffle that
quickly attaches to the condenser coil to provide proper air separation when the unit is
installed in one of the following sleeves: General Electric (metal or plastic). Carrier
(metal or plastic), Amana/ Trane, or McQuay N-series. |
TAX99BK1 |
| POWER DISCONNECT
SWITCH |
A two-pole switch
that easily installs in the subbase of 230/208 V or 265 V units. (TAX99SB subbase
required.) |
TAX99DS |
| CONDUIT KIT WITH
JUNCTION BOX |
Hard wire conduit kit
with junction box for 265V unit (subbase not required). Kit includes a means of quick
disconnect for easy removal of the chassis. |
TAX99CJ |
| THERMOSTAT |
Honeywell 24 V wall
mounted thermostat (requires the appropriate Thermostat Subbase below): - Manual
changeover (T87F2873) |
TAT99TM |
| THERMOSTAT SUBBASE |
Honeywell 24 V
subbase. - Manual changeover (Q539J1006) |
TAT99SM |
| LATERAL DUCT ADAPTER
(Requires Lateral Duct Extension TAX99DE) |
Attaches to the
PTAC/PTHP unit and provides a transition to direct up to 35% of the total CFM to a
secondary room either left or right of the unit. Kit includes duct plenum, with discharge
grille and internal baffle, adapter, end cap and secondary room outlet grille with 2-way
deflection. |
TAX99DA |
| LATERAL DUCT
EXTENSION |
A three foot
insulated plenum that attaches to the left or right side of the duct adapter. The
extension can be cut to length by the installer. Maximum allowable straight extension is
fifteen feet. |
TAX99DE |