Homepage  
Search
find:
search for:
   
 
Site Navigation
News / Publications
Jobs
Service
   Add this page to Google Bookmarks
   Add this page to Mister Wong
   Add this page to del.icio.us
 
   Hastings Industries Inc.  Aeroflo Heaters  

Aeroflo Heaters - Page 3

 

 

AFX SERIES AEROFLO HEATER

Standard Equipment

CABINET

Indoor floor-mounted model.

Reinforced steel surfaces cleaned and painted with heat and corrosion resistant industrial enamel. Unit includes four side return air screens and integral tubular steel structural members for maximum cabinet rigidity.

Low velocity discharge plenum with three sides screened and deflector.

FAN ASSEMBLY

Fans - Heavy-duty, 10 gauge, turbine-bladed propeller fans tested in accordance with AMCA standards. Two fans per unit (AFX-240 through AFX-284), three fans per unit (AFX-360).

Shaft - Cold-rolled steel, machined journals with first critical speed limited to at least 25% above maximum operating speed.

Bearings - Self-aligning, pre lubricated pillow block, thrust bearings, extended grease lines.

MOTORS

Three phase, open drip proof type on adjustable mount. Two motors per unit (AFX-248 through AFX-284), three motors per unit (AFX-360).

DRIVES

Variable pitch sheaves with V-belts safely enclosed within the air intake section.

HEAT EXCHANGER

Primary exchanger, all-welded 14 gauge #430 stainless steel, designed for two passes and transfer of 75% of total heat release. Two staggered sections of black carbon secondary tubes insure maximum combustion efficiency.

FLUE GAS EXHAUSTER

Combustion gas exhaust system includes a heavy-duty exhaust fan, three phase motor. V-belt, or direct drive and heat slinger or direct drive (60A chamber).

CONTROLS

Safety Control - Electronic sequencing burner safety relay with main and pilot flame sensing. Flame rod on gas; photo cell on oil.

Prepurge Timer - Provides four full internal air changes prior to ignition.

Fan / Limit Switch - Provides for continuous fan operation and for burner shutdown.

Draft Switch - Insures operation of exhauster prior to ignition and burner shutdown on loss of draft.

Combustion Air Switch - Prevents burner operation in the absence of proper combustion air flow. Optional with light oil.

Burner Switch - Manually de-energizes burner circuit.

Blower Starter - Magnetic, three-phase, across-the-line.

NEMA 1 Control Box - with dead front disconnect which manually de-energizes blowers and control circuit.

Thermostat - Maintains desired space temperature utilizing two stage return air thermostat.

BURNER

Standard burner is Hi/Lo/Off.

Gas (G) - Power type, with pilot spark ignition and main burner pilot ignition for use with natural, manufactured, mixed, liquefied petroleum gas or liquefied gas/air mixture. Included in the manifold are main gas electric shut-off valve with linkage to combustion air damper, main and pilot gas pressure regulators for maximum inlet pressure of 1 PSI, pilot gas-air mixer and pilot solenoid valve. Minimum standard entering pressure is 4 ozs.

Light Oil (LO) - High pressure oil atomizing type with mechanically forced draft suitable for burning fuels through #2 grade to a maximum of 40 S.S.U. at 100 degrees F.The unit incorporates an oil pump, combustion air fan and drive, combustion air damper operator, oil solenoid valve, oil filter and pressure gauge. An oil pressure regulator is supplied with a pressure system.

Gas/Light Oil (GLO) - Combination fuel, power burner equipped with components as included with gas burner and light oil burner described above. Automatic fuel changeover accomplished by means of an electric toggle switch in the burner control cabinet.

Intake/Discharge Screens - Flattened and expanded metal screens.

FACTORY TESTED

Factory piped, wired and flame tested.


Options and Accessories

Discharge Plenum Extension - For installations where additional height is needed to avoid obstructions, or for tall buildings to insure proper air circulation.

Fresh Air Intake - Motorized damper mounted in fan-section for minimum outside air.

Stainless Steel Secondary Tubes - Recommended for units when air temperature rise on low fire is below 20 degrees F.

FM or IRI Controls - Adds controls for these approvals.

High Gas Pressure Regulator - For inlet pressures from 1 to 75 PSIG.

Low Gas Pressure Controls - Reduces inlet gas pressure requirement by 3 inches w.c.

TEFC Motors - Fan, exhauster and burner motors.

Motor Capacitor - Reduces current draw for energy conservation.

Energy Efficient Motors - Three phase T frame motors reduce power demand with subsequent reduced electric rates.

Modulating Burner - 2:1 full modulating burners are available. Circuit Breaker - in lieu of fused disconnect switch.

NEMA 12 Control Box.

Summer-Winter Switch.

Remote Station - with operating switch and indicating lights.

Day-Night Operation.

Alarm Light or Audible Alarm.

Lockable Thermostat Access Door.

Flatbank Filters - Throwaways, cleanable or extended surface (both sides and rear of unit).

Coils - Chilled water or direct expansion available on most sizes.

U.L. Labeled Control Panels.

Request for Information / Request a Catalog from Hastings Industries Inc.
 
 
 
To request more information from Hastings Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com