| AFX SERIES HEATING SYSTEMS -
SUSPENDED MODELS What is the
AFX Series Heater?
The AFX indirect-fired series is available either as an
Aeroflo large air volume, high air delivery, floor mounted space heater or as a suspended
automatic high volume heater. Both models are designed and applied as space heaters for
modern open area buildings. They achieve uniform building temperature with maximum heating
efficiency using the principle of low velocity constant air circulation to heat large air
volumes to lower temperatures.The Aeroflo series heater is detailed in Bulletin AXF-1
while this brochure describes the suspended AFX model.
How Does the AFX Series Heater
Function?
Continuously circulating the building's air volume several
times each hour, the AFX series heater develops a gentle air rotation pattern, without
requiring a duct system. The air circulation sweeps warmer ceiling air down to the comfort
level, thereby minimizing the stratification.As the suspended heater does not interfere
with normal building activity, AFX series high air supply system maintains room comfort by
spreading lower temperature heat to all corners of the building. As illustrated in Figure
1 and 2, this does not happen with old style equipment which has been designed for a
70º-80º temperature rise. For tall buildings, inlet air ducts can be installed to
provide low level return air.
How Does the AFX Series Heater Save
Energy?
For several reasons, heating larger air volume to
lower temperatures in the AFX series heater reduces fuel consumption in comparison to old
style unit heaters which raise smaller air volumes to higher temperatures.
- Burner operation is reduced because the high volume
air circulation minimizes air stratification, thereby returning warmer air to the heater.
- The larger air volume circulation also utilizes heat
recovered from internal and solar gains normally found at the upper building levels.
- Transmission heat losses are reduced because of lower indoor
-outdoor temperature differentials at the upper building levels.
The low air pressure drop through Hastings heat exchangers
in combination with specially designed propeller fans results in the AFX series suspended
heaters delivering high air volumes at considerably less motor horsepower than comparable
blower type units.This reduces operating power costs.
New AFX Design with Low 26-40 Temperature Rise

Old Style Design with 70-80 Temperature Rise

Field Fabricated Return Air Duct

| MODEL |
DIMENSIONS IN INCHES |
| A |
B |
| AFX-224 |
53-1/8 |
27-7/8 |
| AFX-220 |
46-5/8 |
22-3/4 |
| AFX-120 |
29-1/4 |
23 |
NOTE: Inlet duct should
slip-over the outside of the fan inlet assembly. Some notching and slitting will be
required by the sheet-metal installer. Secure ductwork to the fan assembly to suit. |