   Hastings Industries Inc.  Cooling/Heating Systems  

Cooling/Heating Systems - Page 2

 

 

Blower Table - YR Indoor Models

Model Air
Delivery
SCFM
Blower
used
A B C D E F
MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP
YR-1
1000
MB-112
-
      -
      -
      100
72
1.25
1.75
1/3
1/2
120
87
1.25
1.75
1/3
1/2
-
     
YR-1.5
1500
MB-112
100
48
.72
.98
1/4
1/3
120
58
.98
1.44
1/3
1/2
-
      160
77
.98
1.44
1/3
1/2
-
      200B
  .98
1.44
1/3
1/2
YR-2
2000
MB-112
120
43
1.11
1.6
1/2
3/4
160
58
1.11
1.6
1/2
3/4
-
      200B
72
1.14
1.6
1/2
3/4
240B
87
1.11
1.6
1/2
3/4
-
     
YR-2.5
2500
MB-114A
-
      -
      215
62
1.1
1.6
3/4
1
255
74
1.1
1.6
3/4
1
300
87
1.1
1.6
3/4
1
-
     
YR-3
3000
MB-114A
-
      215
52
.83
1.24
3/4
1
255
61
.83
1.24
3/4
1
300
72
.83
1.24
3/4
1
-
      430B
(*)
99
.83
1.24
3/4
1
YR-4
4000
MB-114A
255
46
1.04
1.61
1-1/2
2
300
54
1.04
1.61
1-1/2
2
-
      430B
78
1.04
1.61
1-1/2
2
-
      510B
92
1.04
1.61
1-1/2
2
YR-5
5000
MB-114B
300
43
1.18
1.98
2
3
400
56
1.18
1.98
2
3
-
              600B
87
1.18
1.98
2
3
       
YR-6
6000
MB-114B
400
47
1.25
2.63
3
5
-
      -
      600B 72 1.25
2.63
3
5
-
      800B
94
1.25
2.63
3
5
YR-7
7000
MB-114B
400
40
1.77
-
5
-
      600B
62
1.77
-
5
-
      800B
80
1.77
-
5
900c
93
1.77
-
5
YR-8
8000
MB-114B
-
      600B
54
2.22
-
7-1/2
-
      800B
70
2.22
7-1/2
900C
81
-
7-1/2
1200c
(*)
99
2.22
-
7-1/2
YR-9
9000
MB-214
600B
48
1.41
2.51
5
7-1/2
-
      800B
63
1.41
2.51
5
7-1/2
900C
72
1.41
2.51
5
7-1/2
-
      1200c
94
1.41
2.51
5
7-1/2
YR-10
10000
MB-214
600B
43
1.99
-
7-1/2
800B
56
1.99
-
7-1/2
900C
65
1.99
-
7-1/2
        1200C
84
1.99
-
7-1/2
-
     

Blower Table - RYR Rooftop Models

Model Air
Delivery
SCFM
Blower
used
A B C D E F
MBH
TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP MBH TR
° F
Max.
TSP
HP
RYR-1
1000
MB-112
-
      -
      -
      100
70
1.25
1.75
1/3
1/2
125
88
1.25
1.75
1/3
1/2
-
     
RYR-1.5
1500
MB-112
100
47
.72
.98
1/4
1/3
125
59
.98
1.44
1/3
1/2
-
      -
      -
      200B
94
.98
1.44
1/3
1/2
RYR-2
2000
MB-112
125
44
1.11
1.6
1/2
3/4
-
      -
      200B
70
1.11
1.6
1/2
3/4
250B
88
1.11
1.6
1/2
3/4
-
     
RYR-2.5
2500
MB-114A
160
45
1.1
1.6
3/4
1
210
59
1.1
1.6
3/4
1
-
      -
      -
      320B
90
1.1
1.6
3/4
1
RYR-3
3000
MB-114A
210
49
.83
1.24
3/4
1
-
      -
      320B
75
.83
1.24
3/4
1
-
      420B
99
.83
1.24
3/4
1
RYR-4
4000
MB-114A
-
      320B
56
1.04
1.61
1-1/2
2
-
      420B
74
1.04
1.61
1-1/2
2
-
      -
     
RYR-4x
4000
MB-114B
250
44
1.3
1.79
1-1/2
2
300
53
1.3
1.79
1-1/2
2
-
      -
      500B
88
1.3
1.79
1-1/2
2
-
     
RYR-5
5000
MB-114B
300
42
1.18
1.98
2
3
-
      -
      500B
70
1.18
1.98
2
3
600B
84
1.18
1.98
2
3
-
     
RYR-6
6000
MB-114B
-
      500B
59
1.25
2.63
3
5
-
      600B
70
1.25
2.63
3
5
750C
88
1.25
2.63
3
5
-
     
RYR-7
7000
MB-114B
-
      500B
50
1.77
-
5
600B
60
1.77
-
5
750C
75
1.77
-
5
-
      900C
90
1.77
-
5
RYR-7x
7000
MB-214
400
40
.64
.91
2
3
-
      -
      -
      800B
80
.91
1.75
3
5
-
     
RYR-8
8000
MB-114B
500B
44
2.22
-
7-1/2
600B
53
2.22
7-1/2
750C
66
2.22
-
7-1/2
900C
79
2.22
-
7-1/2
-
      -
  .81
1.96
3
5
RYR-8x
8000
MB-214
400
35
1.99
7-1/2
-
      -
      800B
70
.81
1.96
3
5
-
      1200C
(*)
99
1.41
2.51
5
7-1/2
RYR-9
9000
MB-214
400
31
1.99
7-1/2
-
      800B
63
1.41
2.51
5
7-1/2
-
      -
      1200C
94
   
RYR-10
10000
MB-214
400
28
1.99
7-1/2
800B
56
1.99
-
7-1/2
-
      -
      1200C
84
1.99
-
7-1/2
-
     

NOTES:(*) Furnaces aerated. Heating shown as MBH input. Maximum total static pressure listed in inches of water at given motor HP.
                 Contact Hastings representative for larger sizes or combinations not shown above.

Equipment Selection - Air Cooled Condensor Unit

  1. Determine the design outside wet bulb temperature of the job location .
  2. Select the design room wet bulb temperature. Use 67 degrees unless specifications call for different bulb.
  3. The total cooling requirement is then "Total Btuh per SCFM" found in the table below multiplied by the SCFM previously determined for air handling section.
  4. Knowing the total cooling load, select the air cooled condensing unit from the YR-RYR capacity tables on page 7 or the condensing unit performance table on page 8.
Design
Room
Wet Bulb
Design Outside Wet Bulb  ° F
66 67 68 69 70 71 72 73 74 75 76 77 78 79 80
° F
65
67
69
Total Btuh per SCFM
3.5 7.0 10.6 14.4 18.1 22.0 26.0 30.1 34.2 38.5 42.8 47.3 51.8 56.5 61.3
- - 3.6 7.3 11.1 15.0 18.9 23.0 27.2 31.5 35.8 40.3 44.8 49.5 54.3
- - - - 3.8 7.6 11.6 15.7 19.8 24.1 28.4 32.9 37.5 42.2 47.0

NOTE: To Obtain Total Btuh for wet Bulb temperature not shown, multiply difference between Design Outside the Room Enthalpy (total heat content) by 4.5

*Request for Information / Request a Catalog
 
 
 
To request more information from Hastings Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com