Blower Table - YR Indoor Models |
| Model |
Air
Delivery
SCFM |
Blower
used |
A |
B |
C |
D |
E |
F |
| MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
YR-1
|
1000
|
MB-112
|
-
|
|
|
|
-
|
|
|
|
-
|
|
|
|
100
|
72
|
1.25
1.75 |
1/3
1/2 |
120
|
87
|
1.25
1.75 |
1/3
1/2 |
-
|
|
|
|
YR-1.5
|
1500
|
MB-112
|
100
|
48
|
.72
.98 |
1/4
1/3 |
120
|
58
|
.98
1.44 |
1/3
1/2 |
-
|
|
|
|
160
|
77
|
.98
1.44 |
1/3
1/2 |
-
|
|
|
|
200B
|
|
.98
1.44 |
1/3
1/2 |
YR-2
|
2000
|
MB-112
|
120
|
43
|
1.11
1.6 |
1/2
3/4 |
160
|
58
|
1.11
1.6 |
1/2
3/4 |
-
|
|
|
|
200B
|
72
|
1.14
1.6 |
1/2
3/4 |
240B
|
87
|
1.11
1.6 |
1/2
3/4 |
-
|
|
|
|
YR-2.5
|
2500
|
MB-114A
|
-
|
|
|
|
-
|
|
|
|
215
|
62
|
1.1
1.6 |
3/4
1 |
255
|
74
|
1.1
1.6 |
3/4
1 |
300
|
87
|
1.1
1.6 |
3/4
1 |
-
|
|
|
|
YR-3
|
3000
|
MB-114A
|
-
|
|
|
|
215
|
52
|
.83
1.24 |
3/4
1 |
255
|
61
|
.83
1.24 |
3/4
1 |
300
|
72
|
.83
1.24 |
3/4
1 |
-
|
|
|
|
430B
|
(*)
99 |
.83
1.24 |
3/4
1 |
YR-4
|
4000
|
MB-114A
|
255
|
46
|
1.04
1.61 |
1-1/2
2 |
300
|
54
|
1.04
1.61 |
1-1/2
2 |
-
|
|
|
|
430B
|
78
|
1.04
1.61 |
1-1/2
2 |
-
|
|
|
|
510B
|
92
|
1.04
1.61 |
1-1/2
2 |
YR-5
|
5000
|
MB-114B
|
300
|
43
|
1.18
1.98 |
2
3 |
400
|
56
|
1.18
1.98 |
2
3 |
-
|
|
|
|
|
|
|
|
600B
|
87
|
1.18
1.98 |
2
3 |
|
|
|
|
YR-6
|
6000
|
MB-114B
|
400
|
47
|
1.25
2.63 |
3
5 |
-
|
|
|
|
-
|
|
|
|
600B |
72 |
1.25
2.63 |
3
5 |
-
|
|
|
|
800B
|
94
|
1.25
2.63 |
3
5 |
YR-7
|
7000
|
MB-114B
|
400
|
40
|
1.77
- |
5
|
-
|
|
|
|
600B
|
62
|
1.77
- |
5
|
-
|
|
|
|
800B
|
80
|
1.77
- |
5
|
900c
|
93
|
1.77
- |
5
|
YR-8
|
8000
|
MB-114B
|
-
|
|
|
|
600B
|
54
|
2.22
- |
7-1/2
|
-
|
|
|
|
800B
|
70
|
2.22
|
7-1/2
|
900C
|
81
|
-
|
7-1/2
|
1200c
|
(*)
99 |
2.22
- |
7-1/2
|
YR-9
|
9000
|
MB-214
|
600B
|
48
|
1.41
2.51 |
5
7-1/2 |
-
|
|
|
|
800B
|
63
|
1.41
2.51 |
5
7-1/2 |
900C
|
72
|
1.41
2.51 |
5
7-1/2 |
-
|
|
|
|
1200c
|
94
|
1.41
2.51 |
5
7-1/2 |
YR-10
|
10000
|
MB-214
|
600B
|
43
|
1.99
- |
7-1/2
|
800B
|
56
|
1.99
- |
7-1/2
|
900C
|
65
|
1.99
- |
7-1/2
|
|
|
|
|
1200C
|
84
|
1.99
- |
7-1/2
|
-
|
|
|
|
Blower Table - RYR Rooftop Models |
| Model |
Air
Delivery
SCFM |
Blower
used |
A |
B |
C |
D |
E |
F |
MBH
|
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
MBH |
TR
° F |
Max.
TSP |
HP |
RYR-1
|
1000
|
MB-112
|
-
|
|
|
|
-
|
|
|
|
-
|
|
|
|
100
|
70
|
1.25
1.75 |
1/3
1/2 |
125
|
88
|
1.25
1.75 |
1/3
1/2 |
-
|
|
|
|
RYR-1.5
|
1500
|
MB-112
|
100
|
47
|
.72
.98 |
1/4
1/3 |
125
|
59
|
.98
1.44 |
1/3
1/2 |
-
|
|
|
|
-
|
|
|
|
-
|
|
|
|
200B
|
94
|
.98
1.44 |
1/3
1/2 |
RYR-2
|
2000
|
MB-112
|
125
|
44
|
1.11
1.6 |
1/2
3/4 |
-
|
|
|
|
-
|
|
|
|
200B
|
70
|
1.11
1.6 |
1/2
3/4 |
250B
|
88
|
1.11
1.6 |
1/2
3/4 |
-
|
|
|
|
RYR-2.5
|
2500
|
MB-114A
|
160
|
45
|
1.1
1.6 |
3/4
1 |
210
|
59
|
1.1
1.6 |
3/4
1 |
-
|
|
|
|
-
|
|
|
|
-
|
|
|
|
320B
|
90
|
1.1
1.6 |
3/4
1 |
RYR-3
|
3000
|
MB-114A
|
210
|
49
|
.83
1.24 |
3/4
1 |
-
|
|
|
|
-
|
|
|
|
320B
|
75
|
.83
1.24 |
3/4
1 |
-
|
|
|
|
420B
|
99
|
.83
1.24 |
3/4
1 |
RYR-4
|
4000
|
MB-114A
|
-
|
|
|
|
320B
|
56
|
1.04
1.61 |
1-1/2
2 |
-
|
|
|
|
420B
|
74
|
1.04
1.61 |
1-1/2
2 |
-
|
|
|
|
-
|
|
|
|
RYR-4x
|
4000
|
MB-114B
|
250
|
44
|
1.3
1.79 |
1-1/2
2 |
300
|
53
|
1.3
1.79 |
1-1/2
2 |
-
|
|
|
|
-
|
|
|
|
500B
|
88
|
1.3
1.79 |
1-1/2
2 |
-
|
|
|
|
RYR-5
|
5000
|
MB-114B
|
300
|
42
|
1.18
1.98 |
2
3 |
-
|
|
|
|
-
|
|
|
|
500B
|
70
|
1.18
1.98 |
2
3 |
600B
|
84
|
1.18
1.98 |
2
3 |
-
|
|
|
|
RYR-6
|
6000
|
MB-114B
|
-
|
|
|
|
500B
|
59
|
1.25
2.63 |
3
5 |
-
|
|
|
|
600B
|
70
|
1.25
2.63 |
3
5 |
750C
|
88
|
1.25
2.63 |
3
5 |
-
|
|
|
|
RYR-7
|
7000
|
MB-114B
|
-
|
|
|
|
500B
|
50
|
1.77
- |
5
|
600B
|
60
|
1.77
- |
5
|
750C
|
75
|
1.77
- |
5
|
-
|
|
|
|
900C
|
90
|
1.77
- |
5
|
RYR-7x
|
7000
|
MB-214
|
400
|
40
|
.64
.91 |
2
3 |
-
|
|
|
|
-
|
|
|
|
-
|
|
|
|
800B
|
80
|
.91
1.75 |
3
5 |
-
|
|
|
|
RYR-8
|
8000
|
MB-114B
|
500B
|
44
|
2.22
- |
7-1/2
|
600B
|
53
|
2.22
|
7-1/2
|
750C
|
66
|
2.22
- |
7-1/2
|
900C
|
79
|
2.22
- |
7-1/2
|
-
|
|
|
|
-
|
|
.81
1.96 |
3
5 |
RYR-8x
|
8000
|
MB-214
|
400
|
35
|
1.99
|
7-1/2
|
-
|
|
|
|
-
|
|
|
|
800B
|
70
|
.81
1.96 |
3
5 |
-
|
|
|
|
1200C
|
(*)
99 |
1.41
2.51 |
5
7-1/2 |
RYR-9
|
9000
|
MB-214
|
400
|
31
|
1.99
|
7-1/2
|
-
|
|
|
|
800B
|
63
|
1.41
2.51 |
5
7-1/2 |
-
|
|
|
|
-
|
|
|
|
1200C
|
94
|
|
|
RYR-10
|
10000
|
MB-214
|
400
|
28
|
1.99
|
7-1/2
|
800B
|
56
|
1.99
- |
7-1/2
|
-
|
|
|
|
-
|
|
|
|
1200C
|
84
|
1.99
- |
7-1/2
|
-
|
|
|
|
NOTES:(*) Furnaces aerated. Heating shown
as MBH input. Maximum total static pressure listed in inches of water at given motor HP.
Contact
Hastings representative for larger sizes or combinations not shown above.
Equipment Selection - Air Cooled
Condensor Unit
- Determine the design outside wet bulb temperature of the job
location .
- Select the design room wet bulb temperature. Use 67 degrees
unless specifications call for different bulb.
- The total cooling requirement is then "Total Btuh per
SCFM" found in the table below multiplied by the SCFM previously determined for air
handling section.
- Knowing the total cooling load, select the air cooled
condensing unit from the YR-RYR capacity tables on page 7 or the condensing unit
performance table on page 8.
Design
Room
Wet Bulb |
Design
Outside Wet Bulb ° F |
| 66 |
67 |
68 |
69 |
70 |
71 |
72 |
73 |
74 |
75 |
76 |
77 |
78 |
79 |
80 |
°
F
65
67
69 |
Total
Btuh per SCFM |
| 3.5 |
7.0 |
10.6 |
14.4 |
18.1 |
22.0 |
26.0 |
30.1 |
34.2 |
38.5 |
42.8 |
47.3 |
51.8 |
56.5 |
61.3 |
| - |
- |
3.6 |
7.3 |
11.1 |
15.0 |
18.9 |
23.0 |
27.2 |
31.5 |
35.8 |
40.3 |
44.8 |
49.5 |
54.3 |
| - |
- |
- |
- |
3.8 |
7.6 |
11.6 |
15.7 |
19.8 |
24.1 |
28.4 |
32.9 |
37.5 |
42.2 |
47.0 |
NOTE: To Obtain Total Btuh for wet Bulb temperature not
shown, multiply difference between Design Outside the Room Enthalpy (total heat content)