Cooling/Heating Systems
Blower Table - Indoor CH Models |
||||||||||||||||||||||||||
| Mode (Nomin Tonnage) | Air Delivery SCFM |
Blower used |
A | B | C | D | E | F | ||||||||||||||||||
| MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | |||
| CH-3 |
1200 |
MB-112 |
- |
- |
100- |
60 | 1.14 1.63 |
1/3 1/2 |
120 | 72 | 1.14 1.63 |
1/3 1/2 |
- | 160 | 96 | 1.14 1.63 |
1/3 1/2 |
|||||||||
| CH-4 |
1600 |
MB-112 |
100 |
45 | .92 1.38 |
1/3 1/2 |
120 | 54 | .92 1.38 |
1/3 1/2 |
- |
160 |
72 | .92 1.38 |
1/3 1/2 |
- |
200B |
90 | .92 1.38 |
1/3 1/2 |
||||||
| CH-5 |
2000 |
MB-112 |
120 |
43 |
1.11 1.6 |
1/2 3/4 |
160 |
58 |
1.11 1.6 |
1/2 3/4 |
- |
200B |
72 |
1.11 1.6 |
1/2 3/4 |
240B |
1.11 1.6 |
1/2 3/4 |
- |
|||||||
| CH-7 | 3000 |
MB-114A |
- |
215 | 52 | .83 1.24 |
3/4 1 |
255 | 61 | .83 1.24 |
3/4 1 |
300 | 72 | .83 1.24 |
3/4 1 |
- | 430B | 104 | .83 1.24 |
3/4 1 |
||||||
| CH-10 |
4000 |
MB-114A |
255 |
46 |
1.04 1.62 |
1-1/2 2 |
300 |
54 |
1.04 1.61 |
1-1/2 2 |
- |
430B |
78 |
1.04 1.62 |
1-1/2 2 |
- |
510B |
92 |
1.04 1.62 |
1-1/2 2 |
||||||
| CH-15 |
6000 |
MB-114B |
400 |
47 |
1.25 2.63 |
3 5 |
- |
- |
600B | 72 | 1.25 2.63 |
3 5 |
- |
800B |
94 |
1.25 2.63 |
3 5 |
|||||||||
| CH-20 |
8000 |
MB-114B |
- |
600B |
54 |
2.22 - |
7-1/2 |
- |
800B |
70 |
2.22 |
7-1/2 |
900C |
2.22 - |
7-1/2 |
1200C |
106 | 2.22 - |
7-1/2 |
|||||||
| CH-25 | 10000 |
MB-214 |
600B |
43 |
1.99 - |
7-1/2 |
800B |
56 |
1.99 - |
7-1/2 |
900C |
65 |
1.99 - |
7-1/2 |
- | 1200C | 84 |
1.99 - |
7-1/2 |
- |
||||||
NOTES : Heating shown as MHB input
Maximum total static pressure listed in inches of water at the given motor HP.
Contact Hasting representative for larger sizes or combinations not shown above.
Blower Table - Rooftop RCH Models |
||||||||||||||||||||||||||
| Mode (Nominal Tonnage) | Air Delivery SCFM |
Blower used |
A | B | C | D | E | F | ||||||||||||||||||
| MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | MBH | TR of |
Max. TSP |
HP | |||
| RCH-3 | 1200 | MB-112 | - | 100 | 59 | 1.14 1.63 |
1/3 1/2 |
- | 125 | 73 | 1.14 1.63 |
1/3 1/2 |
- | - | ||||||||||||
| RCH-4 | 1600 | MB-112 | 100 | 44 | .92 1.38 |
1/3 1/2 |
125 | 55 | .92 1.38 |
1/3 1/2 |
- | - | 200B | 88 | .92 1.38 |
1/3 1/2 |
- | |||||||||
| RCH-5 | 2000 | MB-112 | 125 | 44 | 1.11 1.6 |
1/2 3/4 |
- | - | 200B | 70 | 1.11 1.6 |
1/2 3/4 |
250B | 88 | 1.11 1.6 |
1/2 3/4 |
||||||||||
| RCH-7 | 3000 | MB-114-A | 210 | 49 | .83 1.24 |
3/4 1 |
- | - | 320B | 75 | .83 1.24 |
3/4 1 |
- | 420B | 99 | .83 1.24 |
3/4 1 |
|||||||||
| RCH-10 | 4000 | MB-114-A | 210 | 37 | 1.04 1.62 |
1-1/2 2 |
320B | 56 | 1.04 1.62 |
1-1/2 2 |
- | 420B | 74 | 1.04 1.62 |
1-1/2 2 |
- | - | |||||||||
| RCH-15 | 6000 | MB-114-B | 300 | 35 | 1.25 2.63 |
3 5 |
500B | 59 | 1.25 2.63 |
3 5 |
- | 600B | 70 | 1.25 2.63 |
3 5 |
750C | 88 | 1.25 2.63 |
3 5 |
- | ||||||
| RCH-20 | 8000 | MB-114-B | 500B | 44 | - 2.22 |
7-1/2 | 600B | 53 | - 2.2 |
7-1/2 | 750C | 68 | - 2.22 |
7-1/2 | 900C | 79 | 2.22 | 7-1/2 | - | - | ||||||
| RCH-25 | 10000 | MB-214 | 400 | 28 | 1.99 | 7-1/2 | 800B | 56 | 1.99 - |
7-1/2 | - | - | 1200C | 84 | 1.99 - |
7-1/2 | - | |||||||||
NOTES : Heating shown as MHB input
Maximum total static pressure listed in inches of water at the given motor HP.
Contact Hasting representative for larger sizes or combinations not shown above.
YR-RYR COOLING CAPACITIES
Refrigerant R-22