Standard Equipment & Optional Items
Description |
YR RYR |
CH RCH |
| Blower section
with variable drive (thru 10 H.P. Motor starter (priced separately) Insulation of Blower Section |
Std. Std. Std. |
Std. Std. Std. |
| Natural
(6" to 14") or propane (11" to 15") gas duct furnace(s). Available
with aluminized steel. type 409 stainless steel - recommended. or type 321 stainless steel heat exchanger. Electric ignition, intermittent pilot, N.G. models with 100% or non-100% shut-off. L.P. models with 100% shut-off only. Two stage gas valve(s) Modulating gas valve and by-pass valve manifold. Economizer control package |
Opt. Opt. Opt. (see note) NA Std. NA |
Opt. Opt. Opt. (see note) Opt. Opt. Opt. |
| Power venter and adapter | Opt. | Opt. |
| Factory assembly and wiring | Std. | Std. |
| Fan and system switch in subbase | NA | Std. |
| Cooling/Heating thermostat | Std. | Std. |
| Remote control station with operating switches and indicating lights. | Std. | Opt. |
| Fan time delay relay (furnace) | NA | Std. |
| Filters - 2" throw-away or extended surface | Opt. | Opt. |
| Filters - 2" cleanable | Opt. | Opt. |
| Fresh air intake hood with birdscreen | Opt. | Opt. |
| Fresh air shut-off damper with 2 position motor linkage and end switch | Opt. | NA |
| Mixing dampers with modulating motor and temperature controller | Opt. | Opt. |
| Discharge louver assembly | Opt. | Opt. |
| Vibration isolators (rubber-in-shear or spring) | Opt. | Opt. |
| Fused disconnect switch - air handling unit | Opt. | Opt. |
| Step down transformer | Std. | Std. |
| Two speed motor - 1800/1200 or 1800/900 RPM | Opt. | Opt. |
| High gas pressure regulator - 1/2 PSIG & over | Opt. | Opt. |
| Roof curb and discharge plenum | Opt. | Opt. |
| Air cooled condensing unit package (priced separately) | Std. | Std. |
| Control transformer - condensing unit | Std. | Std. |
| Liquid line solenoid valve. | Std. | Std. |
| Liquid line drier and sight glass | Std. | Opt. |
| Hot gas by-pass regulator | Std. | Opt. |
| Painted cabinet - condensing unit | Opt. | Opt. |
| Fused disconnect switch - condensing unit | Opt. | Opt. |
| Condensing unit gauges | Opt. | Opt. |
| Compressor 3 minute off timer | Opt. | Opt. |
NOTE: Electric ignition non 100% shut-off standard on all RYR/RCH units and YR/CH units having 300 or 400 MBH furnaces. Optional with all other YR/CH units.
Accessory Equipment Air Resistance
Plenums - Allow .10 In. WC - Each
Throw-away Filters/Extended Surface

Cleanable Filters

Fresh Air Shut-off or Mixing Damper

Intake Hood with Birdscreen