architecture - engineering - construction
Hastings Industries Inc.
Cooling/Heating Systems
Cooling/Heating Systems - Page 21
Cooling/Heating Systems
 EC SERIES EVAPORATIVE COOLER
| SPECIFICATIONS |
| Model |
EC-40 |
EC-80 |
EC-120 |
EC-160 |
EC-220 |
EC-300 |
EC-400 |
EC-500 |
EC-600 |
EC-750 |
| Evaporating
Area - Sq.Ft. |
6 |
1.2 |
1.8 |
24 |
32 |
45 |
60 |
70 |
84 |
108 |
Pump
Motor |
Number |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
| HP |
1/50 |
1/6 |
1/6 |
1/6 |
1/C |
1/6 |
(2) 1/6 |
(2) 1/6 |
(2) 1/6 |
(2) 1/6 |
| Amps |
1.1 |
5.0 |
5.0 |
5.0 |
5.0 |
5.0 |
5.0 (ea.) |
5.0 (ea.) |
5.0 (ea.) |
5.0 (ea-) |
| Voltage |
115 Volts - 1
Phase - 60 Hertz |
| Construction |
Reservoir |
Stainless Steel |
| Cabinet |
Aluminized steel -
exterior painted |
| Evaporative
Media |
12" Celdek |
| Water
System |
Schedule 40 PVC
Pipe |
| Shipping
Weight - lbs. |
110 |
176 |
225 |
271 |
310 |
373 |
634 |
726 |
845 |
1067 |
| Operating
Weight - lbs. |
335 |
560 |
650 |
825 |
880 |
1135 |
1680 |
1930 |
2085 |
2635 |
Standard Equipment
Engineers Specifications
Furnish and install the following Hastings
evaporative cooling section:
| Model
Number |
CFM |
115/60/1
Pump Voltage |
The evaporative cooler shall have 12"
CELdek evaporative media, submersible water pump, schedule 40 P.V.C. water
distribution system with splash tube spray over media, cast brass float type fill valve
and manual bleed-off valve for constant sediment drainage. Cabinet to be constructed of 18
gauge aluminized steel with painted exterior. Reservoir to be 20 gauge stainless steel. |
Options and Accessories
- Automatic drain valve kit.
- Automatic drain valve plus freeze protection kit.
- Insulated transitions to Hastings blower sections
- 12" GLASdek media UL approved, UL900, Class 2 rating.
- Flatbank or V-bank pre-filter section.
- 2" throwaway, cleanable or extended surface filters.
- Intake louver with birdscreen.
- Step down transformer for either 208/230 V. 1 Ph. or 230/
- 460 V. 3 Ph.
- Matching base rail for use with Hastings blower section
|
|
EC SERIES EVAPORATIVE COOLER
| SPECIFICATIONS |
| Model |
EC-40 |
EC-80 |
EC-120 |
EC-160 |
EC-220 |
EC-300 |
EC-400 |
EC-500 |
EC-600 |
EC-750 |
| Evaporating
Area - Sq.Ft. |
6 |
1.2 |
1.8 |
24 |
32 |
45 |
60 |
70 |
84 |
108 |
Pump
Motor |
Number |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
| HP |
1/50 |
1/6 |
1/6 |
1/6 |
1/C |
1/6 |
(2) 1/6 |
(2) 1/6 |
(2) 1/6 |
(2) 1/6 |
| Amps |
1.1 |
5.0 |
5.0 |
5.0 |
5.0 |
5.0 |
5.0 (ea.) |
5.0 (ea.) |
5.0 (ea.) |
5.0 (ea-) |
| Voltage |
115 Volts - 1
Phase - 60 Hertz |
| Construction |
Reservoir |
Stainless Steel |
| Cabinet |
Aluminized steel -
exterior painted |
| Evaporative
Media |
12" Celdek |
| Water
System |
Schedule 40 PVC
Pipe |
| Shipping
Weight - lbs. |
110 |
176 |
225 |
271 |
310 |
373 |
634 |
726 |
845 |
1067 |
| Operating
Weight - lbs. |
335 |
560 |
650 |
825 |
880 |
1135 |
1680 |
1930 |
2085 |
2635 |
Standard Equipment
Engineers Specifications
Furnish and install the following Hastings
evaporative cooling section:
| Model
Number |
CFM |
115/60/1
Pump Voltage |
The evaporative cooler shall have 12"
CELdek evaporative media, submersible water pump, schedule 40 P.V.C. water
distribution system with splash tube spray over media, cast brass float type fill valve
and manual bleed-off valve for constant sediment drainage. Cabinet to be constructed of 18
gauge aluminized steel with painted exterior. Reservoir to be 20 gauge stainless steel. |
Options and Accessories
- Automatic drain valve kit.
- Automatic drain valve plus freeze protection kit.
- Insulated transitions to Hastings blower sections
- 12" GLASdek media UL approved, UL900, Class 2 rating.
- Flatbank or V-bank pre-filter section.
- 2" throwaway, cleanable or extended surface filters.
- Intake louver with birdscreen.
- Step down transformer for either 208/230 V. 1 Ph. or 230/
- 460 V. 3 Ph.
- Matching base rail for use with Hastings blower section

|
|