| Counterflo
INDIRECT-FIRED INDUSTRIAL HEATERS Counterflo
FEATURES

LONG FILE COMBUSTION CHAMBER
The floating, heavy gauge, stainless steel combustion
chamber is designed to withstand contraction and expansion cycles to ensure long,
trouble-free operation. The original Counterflo combustion chamber was introduced over
forty years ago. This time-tested reliability and proven performance assures the extended
life of the Counterflo chamber.
AIR COLLED RADIATION SHELD
An internal, air cooled radiation shield is provided to
ensure minimum radiation, to limit transmission losses to less than 2% and to cool
cabinet surfaces.
FLUE GAS EXHAUSTER
The combustion gas exhaust system includes a heavy-duty
exhaust fan, three phase motor, adjustable V-belt drive and heat slinger to yield low
ambient temperature motor operating conditions.
COMPLETE FIELD SERVICE CAPABILITIES
Hastings Industries is the only commercial and
industrial heating and ventilating equipment manufacturer with a company-staffed field
service organization. This insures that Hastings' products are properly built,
properly installed and properly serviced.
FOUR-PASS HEAT EXCHANGE
In the Counterflo heater design, the combustion products
have flow internally four times across the path of the air to be heated. The first two
passes are within the primary heat exchanger, a stainless steel combustion chamber where
the flame and hot gases release 75% of their total heat through contact with the entire
chamber surface. The third and fourth passes are made in the secondary heat
exchanger through two staggered economizer tube sections. The net result is a
compact and highly efficient heat exchange unit.
Typical Schematic Piping Diagram (No optional
Features Shown)

|
Furnished
and installed by Others |
|
Furnished by Factor,
installed by Others |
|
|
|
|
Factory Mounted |
|
|
|
| Key |
Description |
|
|
|
| 1 |
Main Gas Hand Shutoff
Valve |
|
* |
|
| 2 |
Main Gas pressure
Regulator |
|
* |
|
| 3 |
Vent Line |
|
|
* |
| 4 |
Main Gas Valvee |
* |
|
|
| 5 |
Leak Test Petcock
w/Plugged Test Connection |
* |
|
|
| 6 |
Manual Leak Test Hand
Valve |
* |
|
|
| 7 |
Main Burner |
* |
|
|
| 8 |
Pilot Gas Supply Line |
|
|
* |
| 9 |
Pilot Gas Hand Valve |
* |
|
|
| 10 |
Pilot Gas Pressure
Regulator |
* |
|
|
| 11 |
Pilot Gas Selenoid
Valve |
* |
|
|
| 12 |
Pilot Needle Valve |
* |
|
|
| 13 |
Pilot burner |
* |
|
|
| 14 |
Oil Hand Valve |
|
|
* |
| 15 |
Oil Filter |
|
* |
|
| 16 |
Oil Safety Valve |
|
* |
|
| 17 |
Oil Pressure Gauge |
|
* |
|
| 18 |
Oil Pump on Burner |
* |
|
|
| 19 |
Oil Return Line** |
|
|
* |
| 20 |
Check Valve |
|
|
* |
| 21 |
Main Oil Solenoid
Valve |
* |
|
|
*Required for one-pipe pressure system only.
**Added for two-pipe suction system. |