Hastings Industries Inc.
Counterflo Heaters
Counterflo Heaters - Page 3
Counterflo Heaters
| Counterflo INDIRECT-FIRED
INDUSTRIAL HEATERS Standard Equipment CABINET Base heater is indoor upright model, fabricated of 16 gauge Aluminized and/or CRS, heavily reinforced to assure rigidity, and backed by an internal radiation shield. Cooling air, traveling up both sides of the radiation shield, keeps the cabinet surface cool. Air inlets are screened. A pressure relief door and an observation port are provided on the end of the casing where the burner is mounted. The casing is primed and finished with a coat of enamel. FAN ASSEMBLY Fans- Forward curved, DWDI centrifugal fans tested in accordance with AMCA standards. Shaft- Cold-rolled steel machined journals with first critical speed limited to at least 25% above maximum operating speed. Bearings - 200, 000 Hour Self-aligning, pillow block, ball/needle bearings. ENERGY EFFICIENT MOTORS Three phase, open dripproof type on adjustable mount. DRIVES Fixed sheaves with V-belts safely enclosed within the air intake section. HEAT EXCHANGER Primary exchanger, all-welded 14 gauge 400 series stainless steel, designed for two passes and transfer of 75% of total heat release. Two staggered sections of black carbon secondary tubes insure maximum combustion efficiency. FLUE GAS EXHAUSTER Combustion gas exhaust system includes a heavy-duty exhaust fan, motor, adjustable V-belt drive and heat slinger. ELECTRICAL 230/60/3 line current; 115/60/1 control current with transformer furnished for all voltages. CONTROLS Safety Control - Electronic sequencing burner safety relay with main and pilot flame sensing. Flame rod on gas; photo cell on oil. MAIN BLOWER Air Flow Switch - Prevents burner operation in the absence of air flow. Prepurge Timer - Provides for continuous fan operation and for burner shutdown. Draft Switch - Insures operation of exhauster prior to ignition and burner shutdown on loss of draft. Combustion Air Switch - Prevents burner operation in the absence of proper combustion air flow. (Not included with all oil burners.) Burner Switch - Manually de-energizes burner circuit. Blower Starter - Magnetic, three-phase, across the line. NEMA 1 Master Control Panel. Thermostat - Maintains desired space temperature utilizing On-Off space thermostat (for field mounting and wiring.) BURNER Standard burner is On-Off. Gas (G) - Power type, pilot spark ignition and main burner pilot ignition for use with natural, manufactured, mixed liquefied petroleum gas or liquefied gas/air mixture. Included in the manifold are main gas electric shut off valve with linkage to combustion air damper, main and pilot gas pressure regulators for maximum inlet pressure of 1 PSI, pilot gas-air mixer and pilot solenoid valve. Minimum standard entering pressure is 4 ozs. Light Oil (LO) - High pressure oil atomizing type with mechanically forced draft suitable for burning fuels through #2 grade to a maximum of 40 S.S.U. at 100 degrees F. The unit incorporates an oil pump, combustion air fan and drive, combustion air damper operator, oil solenoid valve, oil filter and pressure gauge. An oil pressure regulator is supplied with a pressure system. Gas/Light Oil (GLO) - Combination fuel, power burner equipped with components as included with gas burner and light oil burner described above. Automatic fuel changeover accomplished by means of an electric toggle switch in the burner control cabinet. FACTORY TESTED Factory piped, wired and flame tested. |