| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Hastings Industries Inc. Counterflo Heaters Counterflo Heaters - Page 5
Counterflo Models 40,55,60,85,100 and 125
Specification Data
| |
ITEM * |
MODEL |
| |
|
40 |
55 |
60 |
85 |
100 |
125 |
| HEAT |
OUTPUT - MBH |
400 |
550 |
600 |
850 |
1,000 |
1,250 |
| FUEL CONSUMPTION |
GAS(1000 BTU/CU.FT)-CFH |
500 |
688 |
750 |
1,062 |
1,250 |
1,562 |
| OIL (140 MBH/GAL - GPH |
3.6 |
4.9 |
5.4 |
7.6 |
8.9 |
11.2 |
| COMBUSTION
CHAMBER (400 SERIES S.S) |
GAUGE |
16 |
16 |
16 |
14 |
14 |
14 |
| SURFACE AREA - SQ.FT |
35 |
35 |
60 |
60 |
78 |
78 |
| VOLUME - CU.FT |
17 |
17 |
35 |
35 |
50 |
50 |
| SECONDARY HEAT EXCH. |
COLLECTION BOX GAUGE |
10 |
10 |
10 |
10 |
10 |
10 |
| NO.OF TUBES (4" DIA) |
7 |
7 |
9 |
9 |
11 |
11 |
| |
SURFACE AREA - SQ.FT |
33 |
33 |
40 |
40 |
50 |
50 |
| AIR |
CAPACITY - CFM** |
4,500 |
6,250 |
6,500 |
9,500 |
12,000 |
15,000 |
| TEMPERATURE RISE -
"F" |
82 |
82 |
85 |
82 |
78 |
78 |
| NO. AND DIA (IN) OF
FANS FC,DIDW |
2-15 |
2-15 |
2-15 |
2-15 |
2-15 |
2-18 |
| MAIN FAN MOTOR
(STD) - HP |
1 |
2 |
2 |
5 |
71/2 |
10 |
| DUCT FURNACE
PRESSURE DROP (IN W.C) & |
.60 |
1.20 |
.375 |
.50 |
.75 |
1.05 |
| MISC |
EXHAUSTER MOTOR HP |
1/2 |
1/2 |
1/2 |
1/2 |
3/4 |
3/4 |
| RECOMMENCED STACK
DIA - IN |
8 |
8 |
10 |
10 |
10 |
12 |
| CASING GAUGE |
16 |
16 |
16 |
16 |
16 |
16 |
| SHIPPING WEIGHT -
UPRIGHT MODEL - LBS && |
1400 |
1450 |
1800 |
1900 |
2300 |
2400 |
* Data is based on standard units and
normal conditions 100deg. Tr maximum. For non-standard units and/or application consult
with local representative or the factory.
** Based on standard air(70 deg F and 14,7
psi) with discharge nozzles or equivalent 1/4"W.C TESP. use total External
Static Pressure column that will overcome total system resistance. Approximate
pressure drop for component and accessory items : filter (dirty) 1/4", intake
hood 1/8",birdscreen 1/8",discharge louver 1/4". Damper resistance may be
ignored.
& Based on standard air capacity. Check factory for
optimum applications
&& Approximate weight of basic unit with standard
motor.
Fan Performance
| MODEL |
SCFM* |
TOTAL EXTERNAL STATIC PRESSURE (DUCT OUTLET) - IN W.C. |
| 1/4 |
1/2 |
3/4 |
1 |
1.1/4 |
1.1/2 |
| BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
| CF-40 CF-55 |
4,500 |
0.8 |
1 |
1.1 |
1.5 |
1.4 |
1.5 |
1.7 |
2 |
2.0 |
2 |
2.3 |
3 |
| 5,000 |
1.1 |
1.5 |
1.3 |
1.5 |
1.7 |
2 |
2.0 |
2 |
2.3 |
3 |
2.7 |
3 |
| 5,500 |
1.3 |
1.5 |
1.7 |
2 |
2.0 |
2 |
2.3 |
3 |
2.7 |
3 |
3.2 |
5 |
| 6,000 |
1.7 |
2 |
2.0 |
2 |
2.4 |
3 |
2.8 |
3 |
3.1 |
5 |
3.6 |
5 |
| 7,000 |
2.6 |
3 |
2.9 |
3 |
3.4 |
5 |
3.8 |
5 |
4.2 |
5 |
4.6 |
5 |
| 7,500 |
3.0 |
3 |
3.5 |
5 |
3.9 |
5 |
4.4 |
5 |
4.8 |
5 |
- |
- |
| 8,000 |
3.7 |
5 |
4.2 |
5 |
4.6 |
5 |
4.9 |
5 |
- |
- |
- |
- |
| 8,500 |
4.3 |
5 |
4.8 |
5 |
- |
- |
- |
- |
- |
- |
- |
- |
| 6,500 |
1.7 |
2 |
2.2 |
3 |
2.7 |
3 |
3.2 |
5 |
3.7 |
5 |
4.3 |
5 |
| CF-60 |
7,000 |
2.2 |
3 |
2.6 |
3 |
3.1 |
5 |
3.6 |
5 |
4.2 |
5 |
4.8 |
5 |
| 7,500 |
2.5 |
3 |
3.0 |
3 |
3.6 |
5 |
4.1 |
5 |
4.6 |
5 |
5.2 |
7.5 |
| 8,000 |
3.0 |
3 |
3.5 |
5 |
4.0 |
5 |
4.6 |
5 |
5.2 |
7.5 |
5.8 |
7.5 |
| 8,500 |
3.5 |
5 |
4.2 |
5 |
4.7 |
5 |
5.2 |
7.5 |
5.8 |
7.5 |
6.4 |
7.5 |
| 9,000 |
4.2 |
5 |
4.7 |
5 |
5.3 |
7.5 |
5.8 |
7.5 |
6.4 |
7.5 |
7.0 |
7.5 |
| Cf-85 |
9,500 |
4.7 |
5 |
5.3 |
7.5 |
5.8 |
7.5 |
6.6 |
7.5 |
7.3 |
7.5 |
7.8 |
10 |
| 10,000 |
5.3 |
7.5 |
6.0 |
7.5 |
6.7 |
7.5 |
7.5 |
7.5 |
8.3 |
10 |
8.9 |
10 |
| 10,500 |
6.1 |
7.5 |
6.8 |
7.5 |
7.5 |
7.5 |
8.4 |
10 |
9.3 |
10 |
- |
- |
| 11,000 |
6.9 |
7.5 |
7.7 |
10 |
8.5 |
10 |
9.3 |
10 |
- |
- |
- |
- |
| 11,500 |
8.0 |
10 |
8.7 |
10 |
- |
- |
- |
- |
- |
- |
- |
- |
| 12,000 |
9.0 |
10 |
9.8 |
10 |
- |
- |
- |
- |
- |
- |
- |
- |
| 12,500 |
9.5 |
10 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
| CF-100 |
8,500 |
2.6 |
3 |
3.4 |
5 |
3.8 |
5 |
4.5 |
5 |
5.0 |
5 |
5.6 |
7.5 |
| 9,000 |
3.0 |
3 |
3.8 |
5 |
4.5 |
5 |
5.0 |
5 |
5.7 |
7.5 |
6.2 |
7.5 |
| 10,000 |
4.2 |
5 |
5.0 |
5 |
5.6 |
7.5 |
6.3 |
7.5 |
6.9 |
7.5 |
-7.4 |
7.5 |
| 11,000 |
5.4 |
7.5 |
6.1 |
7.5 |
7.1 |
7.5 |
7.9 |
10 |
8.6 |
10 |
9.4 |
10 |
| 12,000 |
6.4 |
7.5 |
7.6 |
10 |
8.6 |
10 |
9.5 |
10 |
- |
- |
- |
-- |
| 13,000 |
8.3 |
10 |
9.6 |
10 |
- |
- |
- |
- |
- |
- |
- |
-- |
| CF-125 |
14,000 |
6.6 |
7.5 |
7.5 |
7.5 |
8.2 |
10 |
9.3 |
10 |
10.0 |
10 |
11 |
15 |
| 15,000 |
8.0 |
10 |
8.8 |
10 |
9.8 |
10 |
10.7 |
15 |
11.8 |
10 |
|
|
| 16,000 |
9.8 |
10 |
10.7 |
15 |
11.6 |
15 |
12.7 |
15 |
13.6 |
10 |
|
|
| 17,000 |
11.7 |
15 |
12.6 |
15 |
13.6 |
15 |
14.5 |
15 |
- |
- |
|
|
| 18,000 |
13.4 |
15 |
14.7 |
15 |
- |
- |
- |
- |
- |
- |
|
|
* Stainless steel tubes are recommended for high air
capacity with low burner output.
Copyright © 1996-2008 AECinfo.com
|
|