| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Hastings Industries Inc. Counterflo Heaters Counterflo Heaters - Page 7
counterflo Models 275, 3009 3259 350, 400
and 450
Specification Data
| |
ITEM * |
MODEL |
| 275 |
300 |
325 |
350 |
400 |
450 |
| OUTPUT
- MBH |
2,750 |
3@000 |
3,250 |
3500 |
4,000 |
4,500 |
| HEAT |
FUEL
CONSUMPTION |
GAS (1000 BTU/CU.
FT) - CFH |
3,438 |
3,750 |
4,062 |
4,375 |
5,000 |
5,625 |
| OIL (140 MBH/GAL.)
GPH |
24.6 |
26.8 |
29.0 |
31.2 |
35.7 |
40.2 |
| COMBUSTION
CHAMBER (400 SERIES S.S.) |
GAUGE |
14 |
14 |
14 |
14 |
14 |
14 |
| SURFACE AREA - SO.
FT, |
195 |
195 |
195 |
240 |
240 |
240 |
| VOLUME - CU. FT |
181 |
181 |
181 |
245 |
245 |
245 |
| SECONDARY
HEAT EXCH. |
COLLECTION BOX GAUGE |
10 |
10 |
10 |
10 |
10 |
10 |
| NO. OF TUBES
(4" DIA.) |
22 |
22 |
22 |
22 |
22 |
22 |
| SURFACE AREA - SO.
FT. |
252 |
252 |
252 |
310 |
310 |
310 |
| AIR |
CAPACITY
- CFM** |
31,000 |
37,500 |
40,000 |
42,000 |
48,000 |
54,000 |
| TEMPERATURE
RISE - ºF |
82 |
74 |
75- |
77 |
77 |
77 |
| NO. AND
DIA. (IN,) OF FANS (EC, DIDW) |
3-22 |
3-22 |
3-22 |
3-25 |
3-25 |
3-25 |
| MAIN FAN
MOTOR (STD.) - HP |
10 |
15 |
20 |
15 |
20 |
25 |
| DUCT
FURNACE PRESSURE DROP (IN, W.C.) ^ |
.38 |
.55 |
.65 |
.75 |
1.00 |
1.20 |
| MISC. |
EXHAUSTER
MOTOR HP (230160"3 GAS) |
1 |
1 |
1 |
2 |
2 |
2 |
| RECOMMENDED
STACK DIA. - IN. |
16 |
16 |
16_ |
18 |
18 |
18 |
| CASING
GAUGE |
16 |
16 |
16 |
16 |
16 |
16 |
| SHIPPING
WEIGHT UPRIGHT MODEL - LBS. ^ |
6,500 |
6,6251 |
6,750 |
7,025 |
7,055 |
7,205 |
* Data is based on standard units and norma conditions 1
00' TR Maximum. For non-standard units and/or app ication consult with coal representative
or the factory,
** Based on standard air (70'F and 14.7 psi) with discharge
nozz es or equivalent '/," W.C. TFSP Use Total External Static Pressure column that
will overcome total intake hood '/a", birdscreen 1/8", discharge louver
1/4". Damper system resistance, Approximate pressure drop for component and accessory
items, fi ter (dirty) resistance may be ignored.
^ Based on standard air
capacity. Check factory for optimum application.
^ Approximate
weight of basic unit with standard motor.
Fan Performance
TOTAL EXTERNAL STATIC PRESSURE (DUCT OUTLET) -
IN. W.C.
| MODEL |
SCFM* |
1/4 |
1/2 |
3/4 |
1 |
1-1/4 |
1-1/2 |
|
|
BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
BHP |
MHP |
| CF-275 CF-300
CF-325 |
30,000 |
9.5 |
10 |
10.0 |
10 |
11.4 |
15 |
12.3 |
15 |
13.2+ |
15+ |
14.1+ |
15+ |
| 31,000 |
10.0 |
10 |
11.2 |
15 |
12.2 |
15 |
13.0 |
15 |
14.0+ |
15+ |
14.8+ |
15+ |
| 32,000 |
11.0 |
15 |
12.0 |
15 |
12.8 |
15 |
13.7+ |
15+ |
14.6+ |
15+ |
16.5+ |
20+ |
| 33,000 |
11.8 |
15 |
12.8 |
15 |
13.6 |
15 |
14.3+ |
15+ |
16.0+ |
20+ |
18.5+ |
20+ |
| 34,000 |
12.5 |
15 |
13.4 |
15 |
14.3 |
15 |
15.0+ |
15+ |
18.0+ |
20+ |
20.0+ |
20+ |
| 35,000 |
13.2 |
15 |
14.0 |
15 |
15.0+ |
15+ |
17.4+ |
20+ |
20.0+ |
20+ |
22.5+ |
25+ |
| 36,000 |
14.0 |
15 |
14.8 |
15 |
17.0+ |
20+ |
19.5+ |
20+ |
22.0+ |
25+ |
24.5+ |
25+ |
| 37,000 |
14.7 |
15 |
16.5 |
20 |
19.0+ |
20+ |
21.5+ |
25+ |
24.0+ |
25+ |
26.5+ |
30+ |
| 38,000 |
16.0 |
20 |
18.5+ |
20+ |
21.0+ |
25+ |
23.5+ |
25+ |
26.0+ |
30+ |
28.5+ |
30+ |
| 39,000 |
18.0 |
20 |
20.5+ |
25+ |
23.0+ |
25+ |
25.0+ |
25+ |
28.0+ |
O+ |
- |
- |
| 40,000 |
20.0 |
20 |
22.5+ |
25+ |
25.0+ |
25+ |
27.5+ |
30+ |
30.0+ |
30+ |
- |
- |
| 41,000 |
22.0+ |
25+ |
24.5+ |
25+ |
27.0+ |
30+ |
29.5+ |
30+ |
- |
- |
- |
- |
| 42,000 |
24.0+ |
25+ |
26.5+ |
30+ |
29.0+ |
30+ |
- |
- |
- |
- |
- |
- |
| 43,000 |
27.0+ |
30+ |
28.5+ |
30+ |
- |
|
- |
- |
- |
- |
- |
- |
| 44,000 |
29.0+ |
30+ |
30.0+ |
30+ |
- |
|
- |
- |
- |
- |
- |
- |
| CF-350 CF-400
CF-450 |
42,000 |
13 |
15 |
15 |
15 |
17 |
20 |
20 |
20 |
23 |
25 |
96 |
30 |
| 44,000 |
15 |
15 |
17 |
20 |
19 |
20 |
22 |
25 |
25 |
25 |
28 |
30 |
| 45,000** |
16 |
20 |
18 |
20 |
20 |
20 |
23 |
25 |
26 |
30 |
29 |
30 |
| 46,000 |
17 |
20 |
19 |
20 |
21 |
25 |
24 |
25 |
27 |
30 |
30 |
30 |
| 48,000 |
19 |
20 |
21 |
25 |
23 |
25 |
27 |
30 |
29 |
30 |
32 |
40 |
| 50,000 |
21 |
25 |
23 |
25 |
25 |
25 |
29 |
30 |
32 |
40 |
35 |
40 |
| 52,000 |
23 |
25 |
25 |
25 |
27 |
30 |
31 |
40 |
34 |
40 |
37 |
- |
| 54,000 |
25 |
25 |
27 |
30 |
30 |
30 |
34 |
40 |
37 |
40 |
- |
- |
| 56,000 |
28 |
30 |
31 |
40 |
34 |
40 |
37 |
40 |
40 |
40 |
- |
- |
| 58,000 |
30 |
30 |
33 |
40 |
37 |
40 |
39 |
40 |
- |
- |
- |
- |
| 60,000 |
33 |
40 |
37 |
40 |
41 |
50 |
43 |
50 |
- |
- |
- |
- |
| 62,000 |
36 |
40 |
40 |
40 |
44 |
50 |
47 |
50 |
- |
- |
- |
- |
| 64,000 |
40 |
40 |
44 |
50 |
47 |
50 |
- |
- |
- |
- |
- |
- |
| 66,000 |
44 |
50 |
47 |
50 |
- |
- |
|
- |
- |
- |
- |
- |
| 68,000 |
47 |
50 |
51 |
60 |
- |
- |
- |
- |
- |
- |
- |
- |
| 70,000 |
50 |
50 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
*Stainless steel tubes are recommended for high air
capacity with low burner output.
**Minimum CFM for Model 450.
+Requires heavy duty shaft and wheels. - Check Home Office
for Price Add.
Copyright © 1996-2008 AECinfo.com
|
|