Hastings Industries Inc.
Direct Gas Heating
Direct Gas Heating Systems - Page 4
Direct Gas Heating
Options and Accessories General : Horizontal unit blower arrangement -- horizontal up flow (HR - 3) available. Vertical unit blower arrangement -- three Vertical Up and three Vertical Down as illustrated below. ETL Label Available Components: Weatherproof unit - for outdoor installations including hinged and latched weatherproof control enclosure. Insulated blower section - 1 inch, 2 pound density, mat face fiberglass insulation up to leaving air side of burner profile plates. Insulated burner section - available on all units. Storm proof weatherhood - with birdscreen. Installed on air intake of horizontal, HR-1 and HR-2, weatherproof units. Not available with optional vertical blower arrangements. Birdscreen - for installation on the air intake of units with optional vertical blower arrangements. Filter section - with "V" or "Z" frames for mounting 2 inch throwaway, cleanable or extended surface filters. A clogged filter switch with indicating light is available as an optional item. Filter section can also be insulated. Available for return air also. Shut-off dampers - complete with two position damper motor and end switch. Discharge air damper suggested for indoor installations. Low leakage dampers are also available. Discharge air louvers - adjustable horizontal or vertical bladed louvers are available for mounting on the blower outlet. These louvers can be combined for double deflection air control. Service platform - With guardrail per OSHA standard. Service platforms are available for indoor horizontal units only. Vibration isolators - either "rubber-in-shear" or spring type for floor or roof mounting, or indoor suspension. Not compatible with curb mounted units. Vibration isolators are shipped unmounted. Internal fan/motor isolation is also available (Horizontal only) Extended grease lines - for remote greasing of fan bearings from the control side of unit. Panels - U.L labeled main or remote panels. Burner - 50 to 1 turndown available (Not compatible with Selector) Variable pitch sheave - for motors 15 HP and larger. Variable pitch sheaves are standard for motors 10 HP and smaller. Motors : Totally enclosed, two speed, explosion proof, automotive duty or chemical duty motors available on all units. Premium Energy Efficient available. Roof curbs : Adapter frames and roof curbs available for horizontal units. Roof curbs are shipped knocked down. Discharge duct adapters are standard on HR-2 units with discharge dampers. Miscellaneous : Motor and controls can be mounted on opposite side. Matching cooling coil, heat reclaim coil, electric heater and evaporative cooling sections available for all models. Electric Controls : Fused disconnect switch - dead front fused disconnect switch or circuit breaker mounted in cover of main control box. Blocked intake switch - complete with indicating light. Warning light is turned on in case of excessive pressure drop across intake. Low Outlet temperature shut-off - Shuts off blower, after time delay, if unit delivers cold air due to burner failure. Pre-purge cycle - Blower purges unit cabinet for selected time, 7 second minimum, before burner turns on. Not normally required unless unit can fill with combustible vapors between cycles. The item furnished as standard with FM and IRI controls. Circuit analyzer - provides a network of indicating lights to check circuit continuity. Simplifies identification of malfunctioning control. Ultra-violet flame sensor - ultra-violet flame sensing is used in place of standard flame rod system. Desirable for applications where excessive condensation of moisture is encountered. Night setback thermostat - cycles blower-burner on basis of space temperature. Night control can either be energized manually or by a time clock. Note : Burner and Gas control options on page 6 VERTICAL UNIT BLOWER DISCHARGE ARRANGEMENTS (All sections and components are supported by special base frame and vertical support channels) * (Standard support channel heights 112 thru 218 - 24", 222 thru 233 - 26", 240 - 48")
|