| SBE SERIES ELECTROFLO
HEATING SYSTEM OPTIONS AND ACCESSORIES
General:
Horizontal unit blower arrangement
- horizontal up flow (HR-3) available.
Vertical unit blower arrangements - three Vertical
Up and three Vertical Down as illustrated below.
Components:
Weatherproof unit - for outdoor installations with
blower section insulated and hinged, latched weatherproof control enclosure.
Insulated blower section - available on all units.
Insulated electric section - available on all units.
Shut-off dampers - complete with two position damper
motor and end switch. Discharge air damper recommended for outdoor installations and inlet
air damper suggested for indoor units. Low leakage dampers are also available.
Stormproof weatherhood - with birdscreen. Installed
on air intake of horizontal, HR-1 and HR-2, weatherproof units. Not available with
optional vertical blower arrangements.
Birdscreen - for installation on the air intake of
units with optional vertical blower arrangements.
Filter section - with "V" or "Z"
frames for mounting 2 inch throwaway, cleanable or extended surface filters. A clogged
filter switch with indicating light is available as on optional item. Filter section can
also be insulated.
Combination filter/mixing box - complete with mixing
dampers and linkage and a choice of 2 inch filters. A clogged filter switch and indicating
light is available as an optional item.
Damper motors - either modulating or two position
motors are available.
Discharge air louvers - adjustable horizontal or
vertical bladed louvers are available for mounting on the blower outlet. These louvers can
be combined for double deflection air control.
Discharge duct adapter - standard on HR-2 units with
discharge damper and mounted on curbs furnished by Hastings.
Service platform - with guardrail per OSHA standard.
Service platforms are available for indoor horizontal units only.
Vibration isolators - either
"rubber-in-shear" or spring type for floor mounting, roof mounting, or indoor
suspension. Vibration isolators are shipped unmounted. Internal fan/motor isolation is
also available.
Extended grease lines - for remote greasing of fan
bearings from control side of unit.
Variable pitch sheave - for motors 1 5 HP and
larger. Variable pitch sheaves are standard for motors 10 HP and smaller.
Motors:
Totally enclosed motors are available on all units. Two
speed, 1800/1200 RPM motors can be substituted on most SBE models.
Heater:
Full line break contactors - disconnecting contactors
can be furnished in place of de-energizing contactors.
10-step controller - A 1 0-step
electric heater controller may be furnished with any of the Electroflo heating systems.
This increases the control increments above those listed in the Selection Table, SCR solid
state controls are also available on all models.
Electric Controls:
Blocked intake switch - complete with indicating light.
Damper controls - modulating damper motor
controllers.
Non-fused disconnect switch - shipped for field
mounting.
Low outlet temperature shut-off - fan motor is shut
down on heat failure to prevent delivery of cold air.
Roof Curbs:
Adapter frames and roof curbs available for horizontal
units. Roof curbs are shipped knocked down.
Miscellaneous:
Motor and controls can be mounted on opposite side.
Matching cooling coil, heat reclaim coil, direct gas-fired heater and evaporative cooling
section available on all Electroflo units.
VERTICAL UNIT BLOWER
DISCHARGE ARRANGEMENTS
(All sections and components are supported
by special base frame and vertical support channels)
(Standard support channel heights 112 thru
218-24 ", 222 thru 233-26")


|