| Model |
Air
Delivery
-
SCFM |
Discharge
Velocity
-
FPM |
Approx
Shipping
Weight
-
Lbs |
NOMINAL AIR TEMPERATURE RISE IN °F
AND STEPS OF CONTROL |
MOTOR HORSEPOWER |
21-30
2 |
31-40
3 |
41-50
3 |
51-60
4 |
61-70
4 |
71-80
5 |
81-90
5 |
91-100
5 |
TOTAL STATIC PRESSURE
(SEE NOTES BELOW) |
| KW HEATING CAPACITY AND AVAILABLE VOLTAGE |
1/2" |
3/4" |
1" |
1-1/4" |
1-1/2" |
1-3/4" |
2" |
2-1/2" |
3" |
SBE-227 |
28000 |
1713 |
3600 |
+
258 |
+
346 |
+
438 |
+
517 |
+
616 |
*
708 |
*
744 |
- |
7-1/2 |
10 |
10 |
15 |
15 |
15 |
20 |
25 |
25 |
| 30000 |
1835 |
3620 |
+
276 |
+
378 |
+
467 |
+
553 |
+
656 |
*
756 |
**
808 |
- |
10 |
10 |
15 |
15 |
15 |
20 |
20 |
25 |
30 |
| 35000 |
2141 |
3685 |
+
309 |
+
438 |
+
553 |
+
656 |
*
756 |
**
875 |
**
973 |
- |
15 |
15 |
15 |
20 |
20 |
25 |
25 |
30 |
40 |
| 40000 |
2446 |
3685 |
+
378 |
+
497 |
+
616 |
*
756 |
**
875 |
**
973 |
- |
- |
15 |
20 |
20 |
25 |
25 |
25 |
30 |
40 |
40 |
| 45000 |
2752 |
3720 |
+
397 |
+
553 |
*
708 |
**
835 |
**
973 |
- |
- |
- |
255 |
25 |
25 |
30 |
30 |
30 |
40 |
40 |
50 |
| 50000 |
3058 |
3810 |
+
438 |
+
616 |
*
756 |
**
947 |
**
973 |
- |
- |
- |
30 |
30 |
40 |
40 |
40 |
40 |
50 |
50 |
NA |
| 55000 |
3364 |
3565 |
+
497 |
+
692 |
*
835 |
**
973 |
- |
- |
- |
- |
40 |
40 |
40 |
50 |
50 |
50 |
50 |
NA |
NA |
| 60000 |
3670 |
3900 |
+
553 |
*
756 |
++
947 |
**
973 |
- |
- |
- |
- |
50 |
50 |
50 |
50 |
NA |
NA |
NA |
NA |
NA |
SBE-223 |
40000 |
1888 |
5100 |
+
378 |
+
497 |
+
616 |
+
756 |
*
875 |
*
986 |
**
1026 |
- |
15 |
15 |
15 |
20 |
20 |
20 |
25 |
30 |
NA |
| 45000 |
2124 |
5100 |
+
397 |
+
553 |
+
708 |
+
835 |
*
986 |
**
1134 |
**
1211 |
- |
15 |
20 |
20 |
20 |
25 |
25 |
30 |
40 |
40 |
| 50000 |
2360 |
5140 |
+
438 |
+
616 |
+
756 |
+
947 |
**
1107 |
**
1262 |
**
1360 |
- |
20 |
25 |
25 |
25 |
30 |
30 |
40 |
40 |
50 |
| 55000 |
2596 |
5200 |
+
497 |
+
692 |
+
835 |
**
986 |
**
1211 |
**
1373 |
**
1483 |
- |
25 |
30 |
30 |
30 |
40 |
40 |
40 |
50 |
50 |
| 60000 |
2832 |
5235 |
+
553 |
+
756 |
+
947 |
**
1134 |
**
1313 |
**
1483 |
- |
- |
25 |
40 |
40 |
40 |
40 |
40 |
50 |
50 |
60 |
| 65000 |
3067 |
5330 |
+
616 |
+
813 |
**
986 |
**
1211 |
**
1393 |
**
1483 |
- |
- |
40 |
40 |
40 |
40 |
50 |
50 |
50 |
60 |
NA |
| 70000 |
3303 |
5330 |
+
656 |
+
875 |
**
1107 |
**
1313 |
**
1483 |
- |
- |
- |
40 |
50 |
50 |
50 |
50 |
60 |
60 |
CHO |
NA |
| 75000 |
3539 |
5380 |
+
696 |
+
947 |
**
1134 |
**
1393 |
**
1483 |
- |
- |
- |
50 |
60 |
60 |
60 |
60 |
CHO |
CHO |
NA |
NA |
NOTES: 1. KW heating values are based on voltages shown
below. Units will operate satisfactorily at N.E.C. standards
voltages
with slight reduction in heating capacity . + 208,240 or 480 V.3 Ph. ++ 240 V.1 Ph or
208,240 or 480
V.3
Ph. * 240 or 480V.3 Ph. ** 480V.3 Ph.
2. To convert KW
to MBH multiply by 3.412. Air Temperature Rise = MBH x 1000/SCFM x 1.08.
3. Use Total
Static pressure columns that will overcome total system resistance. Approximately
pressure drop for
components
and accessory items: heater element 3/8 "filter (dirty)1/4 " , intake hood 1/8 ,
bird screen 1/8",
discharge
louver, 1/8". Damper resistance may be ignored.
4. Refer to fan
curves in bulletin SB-1 for blower RPM and brake horsepower.
5. Maximum KW per
sq. foot - 28.98 KW per U.L.
6. NA - Not
Available. CHO - Contact Home Office.
TO
SIZE THE OPTIONALMAIN DISCONNECT SWITCH:
Add amps from ITEM A, B and C from the table below, then multiply by 1.25 |
| ITEM |
SOURCE |
AMPS |
| A |
Heating Elements |
Use
KW from selection Table, then calculate : 1 Ph. Amps = KW x 1000
or 3Ph Amps = KW x 1000
voltage
voltage
x 1.73 |
| B |
Blower
Motor |
MOTOR
HP |
1/3 |
1/2 |
3/4 |
1 |
1-1/2 |
2 |
3 |
5 |
7-1/2 |
| AMPS |
240V. 1Ph |
3.6 |
4.9 |
6.9 |
8.0 |
10 |
12 |
17 |
28 |
NA |
| AMPS |
480V.3Ph |
0.8 |
1.0 |
1.4 |
1.8 |
2.6 |
3.4 |
4.8 |
7.6 |
11 |
| MOTOR
HP |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
75 |
| AMPS |
480V.3Ph |
14 |
21 |
27 |
34 |
40 |
52 |
65 |
77 |
96 |
| NOTE: 240V. 3Ph.
AMPS x 2 and 208V. 3Ph. AMPS = 480V. 3Ph. AMPS x 2.2 |
| C |
Controls |
Allow 5 Amps
Maximum |
|