Hastings Industries Inc.
Gas Units
Gas Units - Page 1
Gas Units
GAS-FIRED UNIT HEATERS Hastings gas-fired unit heaters are suspended, self-contained and completely automatic heating devices used for space heating. These units are the ideal heating system for a variety of commercial and industrial applications. They can be applied almost anywhere that space heating is required. Fan models are normally used for space and spot heating. Standard Equipment All Models - Cabinet : Side panels of 20 gauge cold rolled steel., 20 gauge aluminized steel drain pans on all models except GF-400 which is constructed of 18 gauge. Side panels and drain pans are finished with enamel. Adjustable two point hangers on F-50 and GF-100 thru 300. Fixed four point hangers on GF-400 Draft Hood : 22 gauge aluminized steel. Heating Section : Choice of three all electric-welded heat exchange:
Burners are 18 gauge aluminized steel with Type 430 stainless steel ribbon inserts to provide automatic proportioning of primary combustion air. Gas and Electrical Components : 24 volt combination gas valve consisting of main and pilot gas cocks, main and pilot gas pressure regulators, redundant solenoid gas valves, pilot solenoid gas valve and 100% safety shutoff; also high limit control, fan control and 115/24 volt control transformer. Motor(s) : All motors are cushion mounted, have overload protection and are totally enclosed, except for F-50 which has open ventilated motor mounted inside of cabinet. Gas System : For inlet gas pressure of 6" sto 14" w.c. natural gas, or 11" w.c. propane. Horizontal louvers: Allows for 2-way air distribution. Options and Accessories All models - Electronic Ignition systems :
Room thermostats - Several models of 24 volt thermostats available. Fan time delay relay - Used to prevent system fan from short cycling in rooms 50 F. Standard control on GF-400 fan model. Two-stage valve - Provides both 100% and 50% gas input to yield two firing rates. Two stage thermostat is a required extra. Electric ignition required. (not available for F-50) Summer fan switch - For continuous fan operation. 230and 460 volt power - Replaces 115 volt power. High fuel pressure regulators (field installed ):
Power venters - Are generally required where:
Power venters and companion adapters are shipped for field installation and wiring. Dual-Fuel manifold - Natural/LP gas kit includes dual-fuel manifold, spuds and LP gas controls. Pilot remains on natural gas. Available only for field installation. Note : Dual-fuel manifold and power venters are not A.G.A. design certified. Vertical louvers - Offers 4-way air distribution, Standard equipment on F-50 fan model. |