Hastings Industries Inc. Gas Units Gas Units - Page 7

Note : ADJUSTABLE TWO-POINT SUSPENSION BRACKETS FURNISHED
WITH ALL MODELS EXCEPT GFH-360 ALSO FIXED FOUR POINT HANGERS ON GFH-360
DIMENSIONS



| Heater
Size GFH |
Cabinet Dimensions |
Flue
Dia. |
|
Gas
Conn. |
| |
A |
B |
C |
D |
E |
F |
G |
H |
| 100 |
26 1/2 |
33 3/8 |
18 1/8 |
8 9/16 |
16 19/32 |
4 |
195/8 |
1/2 |
| 140 |
26 1/2 |
33 31/32 |
23 7/8 |
8 9/16 |
38 1/8 |
4 |
25 |
1/2 |
| 180 |
26 1/2 |
3629/32 |
29 1/4 |
11 1/2 |
27 3/8 |
4 |
30 3/8 |
3/4 |
| 230 |
29 3/4 |
39 5/8 |
34 5/8 |
11 1/2 |
32 11/16 |
6 |
35 3/4 |
3/4 |
| 280 |
30 3/4 |
39 5/8 |
40 |
11 1/2 |
38 1/8 |
6 |
41 1/8 |
3/4 |
| 360 |
27 1/4 |
37 9/32 |
55 3/4 |
9 |
52 9/16 |
6 |
54 3/8 |
1 |
NOTE: All dimensions in inches
For horizontal venting, 4" or 6" flue pipe
may be used on GHF - 230, 280 and 360.
Required clearance from Combustible material; 6" top,
18" sides and 12" bottom.
Engineers Specifications
- Furnish and install the following (natural gas)
(propane) fired unit heaters as manufactured by Hastings Industries, Inc.
| Item
No. |
Model
No. |
Btuh
Input |
Voltage
Phase |
- Heat exchangers shall have all electric welded
construction with (18 gauge tubes and 16 gauge header plates of aluminized steel)
(.004" tubes and .050" headers plates of type 409 stainless steel) (.041"
tubes and .50" header plates of type 321 stainless steel.
- Burners shall be made of 18 gauge aluminized steel
with type 430 stainless ribbon inserts and shall fire directly into the heat exchanger
tube. There shall be access at the bottom of each heater for the removal of individual
burners and pilot assembly.
- All unit heaters shall have adjustable louvers for
proper air diffusion.
- Gas and electrical components shall consists of not
less than the following 24 volt combination gas valve containing main and pilot gas cocks,
main and pilot gas pressure regulators, redundant solenoid gas valve, and safety shut-off;
also high limit control, fan control and 115/24 volt control transformer.
- Cabinet side panels shall be of 20 gauge cold
rolled steel and drain pans of (20) (18) gauge aluminized steel. Side panels and drain
pans to be finished with enamel.
- Unit heaters shall be A.G.A. design certified.
- The following options and accessories shall be
provided: (select from page 2 of the bulletin).
- All venting shall be done according to state/local
codes.
In order to maintain our policy of continuous product
improvement, we reserve the right to change prices, specifications, rating or dimensions
without notice or obligation.

|