   Hastings Industries Inc.  Gas Units  

Gas Units - Page 14

 

 

Optional Items

Intermittent Pilot with 100% shut-off - Provides increased safety for natural gas firing (standard on propane fired units). It pilot fails to ignite within a given time period, system will lockout and require manual restarting.

230 volt primary /24 volt control circuit - For higher voltage applications.

High fuel pressure regulators :

a. 8" to 15" line pressure (pilot regulator only)

b. 1/2 lb. to 5 lb. line pressure

c. 6 lb. to 40 lb. line pressure (specify gas pressure)

Two-stage gas valve - For applications requiring only make-up air. Direct-acting non-electric valve modulates gas flow to provide constant leaving air temperature.

Modusnap gas valve & by-pass manifold - For application requiring both make-up air and space heating. Modusnap valve provides minimum leaving air temperature and by-pass valve admits full gas input whenever thermostat calls for space heating. Thermostat is a required extra.

"Selectra" Modulation Systems

MS-1 For applications requiring only make-up air, Maxitrol solid state electronic modulating system provides  constant leaving air temperature. Wall mounted "Selectrastat" permits adjustment of discharge air temperature from convenient location.

MS-2: For space heating only applications. Maxitrol solid state electronic modulating system provides continuous blower operation and extremely close control of space temperature. Sensitive to 1/10 F.

MS-3: For make-up air and space heating applications. Same as MS-1, but with two-position overriding room thermostat for space heating as well as make-up air.

Selection Procedure

1 Determine required model size from performance tables using desired Btuch output with desired temperature rise, read pressure drop and corresponding airflow.

2. Choose either gravity vented ("RDG") or power vented ("RDV") model.

3. Also specify heat exchanger type., and any optional items or accessories. Note: For applications where furnace inlet air temperature is 40 F or less, type 409 or type 321 stainless steel heat exchanger is recommended.

gas14a.gif (8255 bytes)

Example : Select rooftop duct furnace for   304,000 Btuch output with 40F temperature rise.Application is space heating with inlet temperature of 60 F in non-corrosive environment. Fuel is natural gas.

Selection :

1. From Table 1, model size no, 400 is chosen with 304,000 Btuch output. For 40F rise,pressure drop = 0.07" W.C. and airflow = 7.040 SCFM.

2. RDG model is picked for gravity venting.

3. Aluminized heat exchanger is chosen.

Selection is thus complete :

RDG-400 with aluminized heat exchanger for natural gas firing. Unit develops 304,000 Btuch output at 0.07"w.c. pressure drop with 40 F rise and 7,040 SCFM.

TABLE 1 - PERFORMANCE FOR SINGLE AND PARALLEL BANK FURNACE MODELS

Air Temp. Rise (F)     10 20 30 40 50 60 70 80 90
Pressure Drop (Inches W.C.)     1.07 .27 .12 .07 .04 .14 .11 .08 .06
Model No. and MBH Input Btuch Output Shipping Weight (Lbs.) Airflow (SCFM)                
100 76,000 266 7040 3520 2345 1760 1410 1175 1005 880 780
125 95,000 286 8800 4400 2935 2200 1760 1470 1260 1100 980
160 121,000 345 11260 5630 3755 2815 2255 1880 1610 1410 1250
210 159,000 364 14780 7390 4925 3695 2955 2465 2115 1850 1645
250 190,000 442 17595 8800 5865 4400 3520 2935 2515 2200 1955
300 228,000 458 21115 10555 7040 5280 4225 3520 3015 2640 2350
400 304,000 562 28150 14075 9380 7040 5630 4690 4025 3520 3130
500A 380,000 964 35190 17600 11730 8800 7040 5870 5030 4400 3910
600A 456,000 996 42230 21110 14080 10560 8450 7040 6030 5280 4700
800A 608,000 1204 56300 28150 18770 14080 11260 9380 8050 7040 6260

TABLE 2 - PERFORMANCE FOR SERIES BANK FURNACE MODELS

Air Temp. Rise (F)     60 70 80 90 100 110 120
Pressure Drop (inches w.c.)     0.24 0.19 0.14 0.11 0.08 0.06 0.05
Model No. and MBH Input Btuch Output Shipping Weight (Lbs.) Airflow (SCFM)            
500B 380,000 924 5865 5030 4400 3910 3520 3200 2935
600B 450,000 956 7040 6030 5280 4700 4225 3840 3520
800B 608,000 1166 9380 8050 7040 6260 5630 5120 4690

NOTE : For Models 500A, 600A,800A 500B and 800B, A.G.A./C.G.A. design certification applies to individual duct furnaces only.

(*) High SCFM type "H" duct furnaces with all Series Bankk Bankk Models or with Single or Parallel Bank Models having 50 degree temperature rise or less. A.G.A./C.G.A. design   certification only applies on installations on installations on the positive side of air supply.

*Request for Information / Request a Catalog
 
 
 
To request more information from Hastings Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free bi-monthly AECnews e-Newsletter.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996-2008 AECinfo.com