Hastings Industries Inc. Heating Systems Heating Systems - Page 3
"R" SERIES
ROOFROP SYSTEMS
Blower Table - RHFA, RMUA & RHVA Models with
Single Bank Furnaces
| Model NO.
& MBH Input |
Btuh Output |
Ship Wt.
Lbs.
(*) |
Blower Used |
Duct Furn.
used |
Air
Temperature Rise |
| 40° |
50° |
60° |
70° |
80° |
90° |
| CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
| 100 |
76,000 |
520 |
112 |
1) 100 |
1,760 |
.84
1.28 |
1/3
1/2 |
1,410 |
1.03
1.50 |
1/3
1/2 |
1,175 |
1.15
1.65 |
1/3
1/2 |
1,005 |
1.24
1.74 |
1/3
1/2 |
880 |
1.05
1.31 |
1/4
1/3 |
780 |
1.10
1.36 |
1/4
1/3 |
| 125 |
95,000 |
550 |
112 |
1) 125 |
2,200 |
.95
1.45 |
1/2
3/4 |
1,760 |
.84
1.28 |
1/3
1/2 |
1,470 |
1.00
1.46 |
1/3
1/2 |
1,260 |
1.11
1.59 |
1/3
1/2 |
1,100 |
1.20
1.69 |
1/3
1/2 |
980 |
1.5
1.76 |
1/3
1/2 |
| 160 |
121,600 |
620 |
114A |
1) 160 |
2,815 |
.93
1.38 |
3/4
1 |
2,255 |
.78
1.21 |
1/2
3/4 |
1,880 |
.93
1.38 |
1/2
3/4 |
1,610 |
.78
1.05 |
1/3
1/2 |
1,410 |
.85
1.12 |
1/3
1/2 |
1,250 |
.91
1.17 |
1/3
1/2 |
| 210 |
159,600 |
670 |
114A |
1) 210 |
3,695 |
.70
1.36 |
1
1-1/2 |
2,955 |
.85
1.27 |
3/4
1 |
2,465 |
1.11
1.62 |
3/4
1 |
2,115 |
.84
1.24 |
1/2
3/4 |
1,850 |
.95
1.38 |
1/2
3/4 |
1,645 |
1.05
1.47 |
1/2
3/4 |
| 250 |
190,000 |
790 |
114B |
1) 250 |
4,400 |
1.05
1.57 |
1-1/2
2 |
3,520 |
.99
1.57 |
1
1-1/2 |
2,935 |
.89
1.21 |
3/4
1 |
2,515 |
1.02
1.35 |
3/4
1 |
2,200 |
1.11
1.45 |
3/4
1 |
1,955 |
1.17
1.53 |
3/4
1 |
| 300 |
228,000 |
840 |
114B |
1) 300 |
5,280 |
.98
1.77 |
2
3 |
4,225 |
1.16
1.67 |
1-1/2
2 |
3,520 |
.99
1.57 |
1
1-1/2 |
3,015 |
1.18
1.84 |
1
1-1/2 |
2,640 |
.95
1.31 |
3/4
1 |
2,350 |
1.07
1.40 |
3/4
1 |
| 400 |
304,000 |
1,175 |
214 |
1) 400 |
7,040 |
.63
1.29 |
2
3 |
5,630 |
1.15
1.85 |
2
3 |
4,690 |
1.09
1.50 |
1-1/2
2 |
4,025 |
1.29
1.75 |
1-1/2
2 |
3,520 |
1.03
1.46 |
1
1-1/2 |
3,130 |
1.14
1.57 |
1
1-1/2 |
| 600 |
456,000 |
2,015 |
218 |
2) 300 |
10,560 |
.81
1.41 |
3
5 |
8,450 |
1.09
1.73 |
3
5 |
7,040 |
.85
1.29 |
2
3 |
6,030 |
.96
1.42 |
2
3 |
5,280 |
.81
1.04 |
1-1/2
2 |
4,700 |
.87
1.11 |
1-1/2
2 |
| 800 |
608,000 |
2,425 |
218 |
2) 400 |
14,080 |
.88
1.50 |
5
7-1/2 |
11,260 |
.72
1.31 |
3
5 |
9,380 |
.97
1.60 |
3
5 |
8,050 |
.75
1.16 |
2
3 |
7,040 |
.85
1.29 |
2
3 |
6,260 |
.94
1.40 |
2
3 |
NOTES: Total static pressure shown in
inches of water
Shaded areas require cleanable filters.
Blower Table - RHFB, RMUB & RHVB Model with
Double Bank Furnaces
| Model NO.
& MBH Input |
Btuh Output |
Ship Wt.
Lbs.
(*) |
Blower Used |
Duct Furn.
used |
Air
Temperature Rise |
| 40° |
50° |
60° |
70° |
80° |
90° |
| CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
CFM |
Total S.P. |
HP |
| 200 |
152,000 |
820 |
112 |
2) 100 |
2,010 |
1.10
1.59 |
1/2
3/4 |
1,760 |
.84
1.28 |
1/3
1/2 |
1,560 |
.95
1.40 |
1/3
1/2 |
1,410 |
1.03
1.50 |
1/3
1/2 |
1,280 |
1.10
1.58 |
1/3
1/2 |
1,175 |
1.15
1.65 |
1/3
1/2 |
| 250 |
190,000 |
880 |
112 |
2) 125 |
2,520 |
.64
1.20 |
1/2
3/4 |
2,200 |
.95
1.45 |
1/2
3/4 |
1,960 |
1.14
1.63 |
1/2
3/4 |
1,760 |
.84
1.28 |
1/3
1/2 |
1,600 |
.93
1.38 |
1/3
1/2 |
1,470 |
1.00
1.46 |
1/3
1/2 |
| 320 |
243,200 |
985 |
114A |
2) 160 |
3,220 |
1.07
1.77 |
1
1-1/2 |
2,815 |
.93
1.38 |
3/4
1 |
2,500 |
1.09
1.59 |
3/4
1 |
2,255 |
.78
1.21 |
1/2
3/4 |
2,050 |
.87
1.30 |
1/2
3/4 |
1,880 |
.93
1.38 |
1/2
3/4 |
| 420 |
319,200 |
1,085 |
114A |
2) 210 |
4,230 |
.80
1.41 |
1-1/2
2 |
3,395 |
.70
1.36 |
1
1-1/2 |
3,290 |
1.08
1.70 |
1
1-1/2 |
2,955 |
.85
1.27 |
3/4
1 |
2,690 |
1.03
1.50 |
3/4
1 |
2,465 |
1.11
1.62 |
3/4
1 |
| 500 |
380,000 |
1,255 |
114B |
2) 250 |
5,030 |
.58
1.16 |
1-1/2
2 |
4,400 |
1.05
1.57 |
1-1/2
2 |
3,910 |
.81
1.35 |
1
1-1/2 |
3,520 |
.99
1.57 |
1
1-1/2 |
3,200 |
1.10
1.78 |
1
1-1/2 |
2,935 |
.89
1.21 |
3/4
1 |
| 600 |
456,000 |
1,355 |
114B |
2) 300 |
6,030 |
.38
1.23 |
2
3 |
5,280 |
.98
1.77 |
2
3 |
4,700 |
.87
1.38 |
1-1/2
2 |
4,225 |
1.16
1.67 |
1-1/2
2 |
3,840 |
.85
1.38 |
1
1-1/2 |
3,520 |
.99
1.57 |
1
1-1/2 |
| 800 |
608,000 |
1,875 |
214 |
2) 400 |
8,050 |
.89
1.94 |
3
5 |
7,040 |
.63
1.29 |
2
3 |
6,260 |
.92
1.60 |
2
3 |
5,630 |
1.15
1.85 |
2
3 |
5,120 |
.96
1.34 |
1-1/2
1 |
4,690 |
1.09
1.50 |
1
1-1/2 |
| 1000 |
760,000 |
3,165 |
218 |
4) 250 |
10,060 |
.87
1.48 |
3
5 |
8,800 |
1.05
1.68 |
3
5 |
7,820 |
.77
1.18 |
2
3 |
7,040 |
.85
1.29 |
2
3 |
6,400 |
.92
1.38 |
2
3 |
5,870 |
.98
1.45 |
2
3 |
| 1200 |
912,000 |
3,305 |
218 |
4) 300 |
12,060 |
1.18
1.84 |
5
7-1/2 |
10,560 |
.81
1.41 |
3
5 |
9,400 |
.97
1.59 |
3
5 |
8,450 |
1.09
1.73 |
3
5 |
7,680 |
.78
1.20 |
2
3 |
7,040 |
.85
1.29 |
2
3 |
| 1600 |
1,216,000 |
3,660 |
218 |
4) 400 |
16,100 |
1.14
1.67 |
7-1/2
10 |
14,080 |
.88
1.50 |
5
7-1/2 |
12,520 |
1.11
1.77
|
5
7-1/2 |
11,260 |
.72
1.31 |
3
5 |
10,240 |
.85
1.46 |
3
5 |
9,380 |
.97
1.60 |
3
5 |
Copyright © 19962008 AECinfo.com
|