| UNHEATED AIR CURTAINS - COMMERCIAL TYPE C MODELS UNHEATED
HASTINGS C MODEL AIR DOORS ARE DESIGNED TO MOUNT OVER
CUSTOMER ENTRANCES.
- They create a curtain of living air undetected by customers
walking through doorway.
- Continually act as a barrier against outside air and maintain
interior conditioned temperature.
| MODEL NO. |
1750 RPM MOTOR H.P. |
AMPS
Single Phase |
Max. FPM AT Nozzle |
Max. CFM at Nozzle |
Wgt.Lbs. |
| 115V |
230V |
| 36C |
1/2 |
5.1 |
2.5 |
2275 |
1700 |
50 |
| 38C |
1/2 |
5.1 |
2.5 |
2150 |
1700 |
52 |
| 42C |
1/2 |
5.1 |
2.5 |
1950 |
1700 |
55 |
| 48C |
1/2 |
5.1 |
2.5 |
1700 |
1700 |
60 |
| 60C |
1/2 |
5.1 |
2.5 |
2040 |
2550 |
65 |
| 60C-2 |
TWO
1/2 |
10.5 |
5.1 |
2720 |
3400 |
95 |
| 72C |
TWO
1/2 |
10.5 |
5.1 |
2275 |
3400 |
105 |
| 96C |
TWO
1/2 |
10.5 |
5.1 |
1700 |
3400 |
130 |
Sound Level 56 Decibels "A" Scale Measured
indoors 10 ft. from nozzle, 2 motors 59 dBA.
CUSTOMER
ENTRANCE DOORS
C Models - Unheated Air Curtains
Purpose : PREVENT LOSS
OF AIR CONDITIONING BARRIER TO DUST, INSECTS AND FUMES. |
| Door Widths Up To |
Door Heights Up To |
Use Model Number |
| 3
ft. |
10
ft. |
36C |
| 31/2
ft. |
10
ft. |
42C |
| 4
ft. |
10
ft. |
48C |
| 5
ft. |
7
ft. |
60C |
| 5
ft. |
10
ft. |
60C-2 |
| 6
ft. |
10
ft. |
72C |
| 7
ft. |
10
ft. |
TWO 42C |
| 8
ft. |
10
ft. |
96C |
| 12
ft. |
10
f/t. |
TWO 72C |
| 15
ft. |
7
ft. |
Three 60C |
RECEIVING/SERVICE
DOORS
CH AND CHS Models - Unheated
Air Curtains Purpose -
ABOVE NORMAL INSECT CONDITIONS. BARRIER TO DUST AND FUMES. |
| Door Widths Up To |
Door Heights Up To |
Use Model Number |
| 3
ft. |
7
ft. |
36CH |
| 31/2
ft. |
7
ft. |
42CH |
| 31/2
ft. |
10
ft. |
42CHS |
| 4
ft. |
7
ft. |
48CH |
| 4
ft. |
10
ft. |
48CHS |
| 5
ft. |
10
ft. |
60CHS-2 |
| 5
ft. |
10
ft. |
60CHS
|
| 6
ft. |
7
ft. |
72CH |
| 7
ft. |
7
ft. |
Two
42 CH |
| 8
ft. |
10
ft. |
96CHS |
| 10
ft. |
7
ft. |
Two
60 CHS |
| 12
ft. |
10
ft. |
48CHS
& 96CHS |


CH/HS MODELS UNHEATED
RECOMMENDED FOR ABOVE NORMAL INSECT CONDITIONS. Receiving
and service entrance doors - markets - restaurants - hospitals -food processing plants -
schools, etc. Inside or outside installation equally effective,. Characteristics : Produce
greater velocity of air with slightly higher sound level as compared to C models
| MODEL NO. |
1750 RPM MOTOR H.P. |
AMPS Single Phase |
Max. FPM AT Nozzle |
Max. CFM at Nozzle |
Wgt.Lbs. |
| 115V |
230V |
|
|
|
| 36CH |
1/2 |
5.1 |
2.5 |
3400 |
2550 |
50 |
| 38CH |
1/2 |
5.1 |
2.5 |
3225 |
2550 |
52 |
| 42CH |
1/2 |
5.1 |
2.5 |
2925 |
2550 |
55 |
| 48CH |
1/2 |
5.1 |
2.5 |
2550 |
2550 |
60 |
| 60CH-2 |
TWO
1/2 |
10.2 |
5.1 |
4080 |
5100 |
95 |
| 72CH |
TWO
1/2 |
10.2 |
5.1 |
3400 |
5100 |
105 |
| 96CH |
TWO
1/2 |
10.2 |
5.1 |
2550 |
5100 |
130 |
| CHS MODELS |
| 42CHS |
1 |
16.0 |
8.0 |
4600 |
4000 |
80 |
| 48CHS |
1 |
16.0 |
8.0 |
4000 |
4000 |
85 |
| 60CHS |
1 |
16.0 |
8.0 |
3200 |
4000 |
90 |
| 96CHS |
Two
1 HP |
32.0 |
16.0 |
4000 |
8000 |
160 |
| Second level :
"A" Scale Measure indoors 10 ft from air outlet nozzle CH models with 1/2 HP motors are 63 dBA. Two motors 65dBA
CHS models with 1 HP motors are 69dBA. Two motors 72 dBA |
COOLERS
: For temperatures of
+ 25° to +60° F |
FREEZERS
: for temperatures of
-20° to +25° F |
Door
widths
Up To |
Door
Heights
Up To |
Use
Model
No. |
Door
Widths
Up To |
Door
Heights
Up to |
Use
Model
No. |
| 3 ft |
8ft |
36C |
3ft |
8ft |
36CH |
| 3 1/2 ft |
8 ft |
42C |
3 1/2 ft |
8ft |
42CH |
| 4ft |
8ft |
48C |
4ft |
8ft |
48CH |
| 5 ft |
10ft |
60C-2 |
5ft |
10ft |
60C-2 |
| 5ft |
10ft |
60CH-2 |
5ft |
10ft |
60CH-2 |
| 6ft |
8ft |
72C |
6ft |
8ft |
72CH |
| 7ft |
8ft |
Two 42C |
7ft |
8ft |
Two 42CH |
| 8ft |
8ft |
96C |
8ft |
8ft |
96CH |
| 10ft |
10ft |
Two 60C-2 |
10ft |
10ft |
Two 60C-2 |
| 10ft |
10ft |
Two 60CH-2 |
10ft |
10ft |
Two 60CH-2 |
OPTIONAL : Micro Switch for automatic
on/off control. When door is opened Hastings Air Door will start automatically and stop
when closed
DECORATIVE COLORS : Gold, Grey, Dark Bronze or Beige on
request. White is regular production color.
For unusual or problem openings consult factory
representative for suggestion regarding most practical and efficient type of installation.
For higher cooler doors use the CH Models. |