AIR DOORS - INDUSTRIAL TYPE
AIR DIRECTIONAL CONTROL AND
AIR VELOCITY CONTROL FOR VARIABLE AIR SPEED
STANDARD MODELS

ADJUSTMENT OF AIR FLOW FOR
DUST, INSECTS & FUMES

ADJUSTMENT OF AIR FLOW FOR
COLD WEATHER, COOLERS AND FREEZERS
When used to prevent cold winter air entering
building, Air Door must be installed on warm side.
For insect control, Air Door is equally
efficient whether mounted inside or outside the exterior wall.
PERFORMANCE SPECIFICATIONS
| STANDARD MODELS AVAILABLE |
FT- PER MINUTE AT NOZZLE |
CFM AT NOZZLE |
MOTORS |
SINGLE PHASE TOTAL AMPS |
SHIP W.T. (lbs.) |
| H.P |
R.P.M. |
115 V. |
208 V.230V. |
| 28 (2'
4") |
3275 |
1900 |
1/3 HP |
3450 |
3.4 |
1.8 |
50 |
| 36 (3") |
3400 |
2550 |
1/2HP |
1750 |
5.1 |
2.5 |
73 |
| 42 (3'6") |
2925 |
2550 |
1/2HP |
1750 |
5.1 |
2.5 |
80 |
| 48 (4") |
2550 |
2550 |
1/2HP |
1750 |
5.1 |
2.5 |
87 |
| 48 HV (4") |
4000 |
4000 |
1 HP |
1750 |
16.0 |
8.0 |
120 |
| 60 (5") |
3040 |
3800 |
1/3 HP |
3450 |
7.0
|
3.5 |
94 |
| 60 HV (5") |
3200 |
4000 |
Two 1/3
HP |
1750 |
16.0 |
8.0 |
140 |
| 78 (6'6") |
3200 |
5100 |
Two 1/2 HP |
1750 |
10.2 |
5.0 |
146 |
| 84 HV (7") |
4570 |
8000 |
Two 1 HP |
1750 |
32.0 |
16.0 |
210 |
| 96 NV (8") |
4000 |
8000 |
Two 1 HP |
1750 |
32.0 |
16.0 |
225 |
| 120 HV-2
(10") |
3200 |
8000 |
Two 1 HP |
1750 |
32.0 |
16.0 |
240 |
| 120 HV-3
(10") |
4800 |
12000 |
Three 1 HP |
1750 |
48.0 |
24.0 |
300 |
| 144 HV
(12") |
4000 |
12000 |
Three 1 HP |
1750 |
48.0 |
24.0 |
310 |
RECOMMENDED
STANDARD MODELS
| DOOR WIDTHS UP TO |
HEIGHTS UP TO |
USE THIS MODEL NUMBER |
| 3 ft. |
7 ft. |
36 |
| 3-1/2 ft. |
7 ft. |
42 |
| 4 ft. |
7 ft. |
48 |
| 4-1/2 ft. |
12 ft. |
48 HV |
| 5 ft. |
7 ft. |
60 |
| 5 ft. |
10 ft. |
60 HV |
| 7 ft. |
7 ft. |
78 |
| 7 ft. |
14 ft. |
84 HV |
| 8 ft. |
12 ft. |
96 HV |
| 10 ft. |
10 ft. |
120HV-2 |
| 10 ft. |
14 ft. |
120 HV-3 |
| 12 ft. |
12 ft. |
144 HV |
| 14 ft. |
14 ft. |
TWO 84 HV |
PURPOSE
:CONTAIN BUILDING CONDITIONED AIR WHETHER HEATED OR AIR CONDITIONED
| DOOR WIDTHS UP TO |
HEIGHTS UP TO |
USE THIS MODEL NUMBER |
| 2-1/2
ft. |
7
ft. |
28 |
| 3
ft. |
7
ft. |
36 |
| 3-1/2
ft. |
7
ft. |
42 |
| 4
ft. |
7
ft. |
48 |
| 4-1/2
ft. |
10
ft. |
48 HV |
| 5
ft. |
7
ft. |
60 |
| 5
ft. |
10
ft. |
60 HV |
| 7
ft. |
7
ft. |
78 |
| 7
ft. |
10
ft. |
84 HV |
| 8
ft. |
10
ft. |
96 HV |
| 10
ft. |
8
ft. |
120 HV-2 |
| 10
ft. |
10
ft. |
120 HV-3 |
| 12
ft. |
10
ft. |
144 HV |
| 14
ft. |
10
ft. |
Two 84 HV |
PURPOSE :
BARRIER TO INSECTS, DUST AND FUMES.
PURPOSE : PREVENT LOSS OF
REFRIGERATED AIR.
| DOOR WIDTHS UP TO |
HEIGHTS UP TO |
USE THIS MODEL NUMBER |
| 2 -
1/2 ft. |
10 ft. |
28 |
| 3 ft. |
10 ft. |
36 |
| 3 -
1/2 ft. |
10 ft. |
42 |
| 4 ft. |
10ft. |
48 |
| 5 ft. |
10 ft. |
60-2 |
| 7 ft. |
10 ft. |
78-2 |
| 7 ft. |
10 ft. |
84-2 |
| 8 ft. |
10 ft. |
96-2 |
| 8 ft. |
12 ft. |
96-3 |
| 10 ft. |
12 ft. |
120-3 |
| 12 ft. |
10 ft. |
144-3 |
| 12 ft. |
12 ft. |
144-4 |
| 4 -
1/2 ft. |
16 ft. |
48 HV |
| 5 ft. |
14 ft. |
60 HV |
| 7 ft. |
16 ft. |
84 HV-2 |
| 8 ft. |
16 ft. |
96 HV-2 |
| 10 ft. |
12 ft. |
120 HV-2 |
| 10 ft. |
16 ft. |
120 HV-3 |
| 12 ft. |
16ft. |
144 HV-3 |
| 14 ft. |
16 ft. |
Two HV-2 |
COOLERS : + 25 to + 60 F.
PURPOSE : PREVENT LOSS OF
REFRIGERATED AIR.
| DOOR WIDTHS UP TO |
HEIGHTS UP TO |
USE THIS MODEL NUMBER |
| 2 -
1/2 ft. |
8
ft. |
26 |
| 3
ft. |
8
ft. |
36 |
| 3 -
1/2 ft. |
8ft. |
42 |
| 4
ft. |
8
ft. |
48 |
| 5
ft. |
8
ft. |
60-2 |
| 7
ft. |
8
ft. |
78-2 |
| 7
ft. |
8
ft. |
84-2 |
| 8
ft. |
8
ft. |
96-2 |
| 8ft. |
9
ft. |
96-3 |
| 10
ft. |
9
ft. |
120-3 |
| 12
ft. |
8
ft. |
144-3 |
| 12
ft. |
9
ft. |
144-4 |
| 4-1/2
ft. |
12ft. |
48 HV |
| 5
ft. |
12
ft. |
60 HV |
| 7
ft. |
12
ft. |
84 HV-2 |
| 8
ft. |
13
ft. |
96 HV-2 |
| 10
ft. |
10
ft. |
120 HV-2 |
| 10
ft. |
14
ft. |
120 HV-3 |
| 12
ft. |
14ft. |
144 HV-3 |
| 14 ft. |
12 ft. |
Two 84 HV-2 |
FREEZERS : -20 TO +25 F.
EXTRA POWER MODELS
FOR HIGHER OPENINGS UP TO 16 FEET
SPECIFY EXTRA POWER MODELS
(CONTAIN 3HP MOTORS)
PERFORMANCE
SPECIFICATIONS
| STANDARD MODELS AVAILABLE |
FT. PER MINUTE AT NOZZLE |
CFM AT NOZZLE |
MOTORS |
SINGLE PHASE TOTAL AMPS |
THREE PHASE TOTAL AMPS |
SHIP WT. (lbs.) |
| H.P |
R.P.M |
115 V. |
208 V.
230 V. |
208 V.
230 V. |
480 V. |
| EP 48 (4') |
4800 |
4800 |
3HP |
3450 |
30.0 |
15.0 |
8.0 |
4.0 |
120 |
| EP 60 (5') |
3840 |
4800 |
3HP |
3450 |
30.0 |
15.0 |
8.0 |
4.0 |
155 |
| EP 84-2 (7') |
5485 |
9600 |
Two 3HP |
3450 |
60.0 |
30.0 |
16.0 |
8.0 |
215 |
| EP 96-2 (8') |
4800 |
9600 |
Two 3HP |
3450 |
60.0 |
30.0 |
16.0 |
8.0 |
225 |
| EP 120-2 (10') |
3840 |
9600 |
Two 3HP |
3450 |
60.0 |
30.0 |
16.0 |
8.0 |
250 |
| EP 120-3 (10') |
5760 |
14,400 |
Three 3HP |
3450 |
90.0 |
45.0 |
24.0 |
12.0 |
310 |
| EP 144-2 (12') |
4000 |
14,000 |
Three 3HP |
3450 |
90.0 |
45.0 |
24.0 |
12.0 |
330 |
| Decibel Readings "A" Scale Measured 10 Feet From
Nozzle |
| Models |
1 Motor |
2 Motor |
3 Motors |
4 Motors |
| Standard 1/2 Hp |
66 |
68 |
71 |
73 |
| High Velocity 1
Hp |
70 |
73 |
75 |
- |
| Extra Power 3
HP |
76 |
79 |
81 |
- |
RECOMMENDED
EXTRA POWER MODELS
| DOOR WIDTHS UP TO |
*HEIGHTS UP TO |
USE THIS MODEL NUMBER |
| 4 -
1/2 ft. |
16
ft. |
EP
48 |
| 5
ft. |
12
ft. |
EP
60 |
| 7
ft. |
16
ft. |
EP
84-2 |
| 8
ft. |
16
ft. |
EP
96-2 |
| 10
ft. |
12
ft. |
EP
120-2 |
| 10
ft. |
16
ft. |
EP
120-3 |
| 12
ft. |
16ft. |
EP
144-3 |
| 14
ft. |
16
ft. |
Two
EP 84-2 |
| DOOR WIDTHS UP TO |
*HEIGHTS UP TO |
USE THIS MODEL NUMBER |
| 16
ft. |
16
ft. |
Two
EP 96-2 |
| 18
ft. |
16
ft. |
EP
96 & EP 120-3 |
| 20
ft. |
12
ft. |
Two
EP 120-2 |
| 20 |
16
ft. |
Two
EP 120-3 |
Hastings Air Doors will hold winds up to a maximum 0f
15 MPH but they cannot be completely held out when there is an indraft caused by negative
pressure in the building. A wind tunnel effect is likely to occur if other outside doors,
windows or roof ventilators are completely open.
Hastings Air Doors meet government specifications of 1600 feet per
minute 3 feet floor. All Air Doors have one second motor start to full capacity
operation. |