AIR DOORS - INDUSTRIAL TYPE

AIR DIRECTIONAL CONTROL AND AIR VELOCITY CONTROL FOR VARIABLE AIR SPEED

STANDARD MODELS

misc04a.gif (8238 bytes)

ADJUSTMENT OF AIR FLOW FOR
DUST, INSECTS & FUMES

misc04b.gif (7222 bytes)

ADJUSTMENT OF AIR FLOW FOR
COLD WEATHER, COOLERS AND FREEZERS

When used to prevent cold winter air entering building, Air Door must be installed on warm side.

For insect control, Air Door is equally efficient whether mounted inside or outside the exterior wall.

PERFORMANCE SPECIFICATIONS

STANDARD MODELS AVAILABLE FT- PER MINUTE AT NOZZLE CFM AT NOZZLE MOTORS SINGLE PHASE TOTAL AMPS SHIP W.T. (lbs.)
H.P R.P.M. 115 V. 208 V.230V.
28  (2' 4") 3275 1900 1/3 HP 3450 3.4 1.8 50
36 (3") 3400 2550 1/2HP 1750 5.1 2.5 73
42 (3'6") 2925 2550 1/2HP 1750 5.1 2.5 80
48 (4") 2550 2550 1/2HP 1750 5.1 2.5 87
48 HV (4") 4000 4000 1 HP 1750 16.0 8.0 120
60 (5") 3040 3800 1/3 HP 3450 7.0   3.5 94
60 HV (5") 3200 4000   Two 1/3 HP 1750 16.0 8.0 140
78 (6'6") 3200 5100 Two 1/2 HP 1750 10.2 5.0 146
84 HV (7") 4570 8000 Two 1 HP 1750 32.0 16.0 210
96 NV (8") 4000 8000 Two 1 HP 1750 32.0 16.0 225
120 HV-2 (10") 3200 8000 Two 1 HP 1750 32.0 16.0 240
120 HV-3 (10") 4800 12000 Three 1 HP 1750 48.0 24.0 300
144 HV (12") 4000 12000 Three 1 HP 1750 48.0 24.0 310

RECOMMENDED STANDARD MODELS

DOOR WIDTHS UP TO HEIGHTS UP TO USE THIS MODEL NUMBER
3 ft. 7 ft. 36
3-1/2 ft. 7 ft. 42
4 ft. 7 ft. 48
4-1/2 ft. 12 ft. 48 HV
5 ft. 7 ft. 60
5 ft. 10 ft. 60 HV
7 ft. 7 ft. 78
7 ft. 14 ft. 84 HV
8 ft. 12 ft. 96 HV
10 ft. 10 ft. 120HV-2
10 ft. 14 ft. 120 HV-3
12 ft. 12 ft. 144 HV
14 ft. 14 ft. TWO 84 HV

PURPOSE :CONTAIN BUILDING CONDITIONED AIR WHETHER HEATED OR AIR CONDITIONED

DOOR WIDTHS UP TO HEIGHTS UP TO USE THIS MODEL NUMBER
2-1/2 ft. 7 ft. 28
3 ft. 7 ft. 36
3-1/2 ft. 7 ft. 42
4 ft. 7 ft. 48
4-1/2 ft. 10 ft. 48 HV
5 ft. 7 ft. 60
5 ft. 10 ft. 60 HV
7 ft. 7 ft. 78
7 ft. 10 ft. 84 HV
8 ft. 10 ft. 96 HV
10 ft. 8 ft. 120 HV-2
10 ft. 10 ft. 120 HV-3
12 ft. 10 ft. 144 HV
14 ft. 10 ft. Two 84 HV

PURPOSE : BARRIER TO INSECTS, DUST AND FUMES.

PURPOSE : PREVENT LOSS OF REFRIGERATED AIR.

DOOR WIDTHS UP TO HEIGHTS UP TO USE THIS MODEL NUMBER
2 - 1/2 ft. 10 ft. 28
3 ft. 10 ft. 36
3 - 1/2 ft. 10 ft. 42
4 ft. 10ft. 48
5 ft. 10 ft. 60-2
7 ft. 10 ft. 78-2
7 ft. 10 ft. 84-2
8 ft. 10 ft. 96-2
8 ft. 12 ft. 96-3
10 ft. 12 ft. 120-3
12 ft. 10 ft. 144-3
12 ft. 12 ft. 144-4
4 - 1/2 ft. 16 ft. 48 HV
5 ft. 14 ft. 60 HV
7 ft. 16 ft. 84 HV-2
8 ft. 16 ft. 96 HV-2
10 ft. 12 ft. 120 HV-2
10 ft. 16 ft. 120 HV-3
12 ft. 16ft. 144 HV-3
14 ft. 16 ft. Two HV-2

COOLERS : + 25 to + 60 F.

PURPOSE : PREVENT LOSS OF REFRIGERATED AIR.

DOOR WIDTHS UP TO HEIGHTS UP TO USE THIS MODEL NUMBER
2 - 1/2 ft. 8 ft. 26
3 ft. 8 ft. 36
3 - 1/2 ft. 8ft. 42
4 ft. 8 ft. 48
5 ft. 8 ft. 60-2
7 ft. 8 ft. 78-2
7 ft. 8 ft. 84-2
8 ft. 8 ft. 96-2
8ft. 9 ft. 96-3
10 ft. 9 ft. 120-3
12 ft. 8 ft. 144-3
12 ft. 9 ft. 144-4
4-1/2 ft. 12ft. 48 HV
5 ft. 12 ft. 60 HV
7 ft. 12 ft. 84 HV-2
8 ft. 13   ft. 96 HV-2
10 ft. 10 ft. 120 HV-2
10 ft. 14 ft. 120 HV-3
12 ft. 14ft. 144 HV-3
14 ft. 12 ft. Two 84 HV-2

FREEZERS : -20 TO +25 F.


EXTRA POWER MODELS

FOR HIGHER OPENINGS UP TO 16 FEET
SPECIFY EXTRA POWER MODELS
(CONTAIN 3HP MOTORS)

PERFORMANCE SPECIFICATIONS

STANDARD MODELS AVAILABLE FT. PER MINUTE AT NOZZLE CFM AT NOZZLE MOTORS SINGLE PHASE TOTAL AMPS THREE PHASE TOTAL AMPS SHIP WT. (lbs.)
H.P R.P.M 115 V. 208 V.
230 V.
208 V.
230 V.
480 V.
EP 48 (4') 4800 4800 3HP 3450 30.0 15.0 8.0 4.0 120
EP 60 (5') 3840 4800 3HP 3450 30.0 15.0 8.0 4.0 155
EP 84-2 (7') 5485 9600 Two 3HP 3450 60.0 30.0 16.0 8.0 215
EP 96-2 (8') 4800 9600 Two 3HP 3450 60.0 30.0 16.0 8.0 225
EP 120-2 (10') 3840 9600 Two 3HP 3450 60.0 30.0 16.0 8.0 250
EP 120-3 (10') 5760 14,400 Three 3HP 3450 90.0 45.0 24.0 12.0 310
EP 144-2 (12') 4000 14,000 Three 3HP 3450 90.0 45.0 24.0 12.0 330

 

Decibel Readings "A" Scale Measured 10 Feet From Nozzle
Models 1 Motor 2 Motor 3 Motors 4 Motors
Standard 1/2 Hp 66 68 71 73
High Velocity 1 Hp 70 73 75 -
Extra Power 3 HP 76 79 81 -

RECOMMENDED EXTRA POWER MODELS

DOOR WIDTHS UP TO *HEIGHTS UP TO USE THIS MODEL NUMBER
4 - 1/2 ft. 16 ft. EP 48
5 ft. 12 ft. EP 60
7 ft. 16 ft. EP 84-2
8 ft. 16 ft. EP 96-2
10 ft. 12 ft. EP 120-2
10 ft. 16 ft. EP 120-3
12 ft. 16ft. EP 144-3
14 ft. 16 ft. Two EP 84-2

 

DOOR WIDTHS UP TO *HEIGHTS UP TO USE THIS MODEL NUMBER
16 ft. 16 ft. Two EP 96-2
18 ft. 16 ft. EP 96 & EP 120-3
20 ft. 12 ft. Two EP 120-2
20 16 ft. Two EP 120-3

Hastings Air Doors will hold winds up to a maximum 0f 15 MPH but they cannot be completely held out when there is an indraft caused by negative pressure in the building. A wind tunnel effect is likely to occur if other outside doors, windows or roof ventilators are completely open.

Hastings Air Doors meet government specifications of 1600 feet per minute 3 feet floor. All Air Doors  have one second motor start to full capacity operation.

*Request for Information / Request a Catalog
 
 
 
To request more information from Hastings Industries Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com