| STEAM "SBS" AND HOT
WATER "SBW" SYSTEMS OPTIONS AND
ACCESSORIES
General :
Horizontal unit blower arrangements-horizontal up flow(HR-3)
available.
Vertical unit blower arrangements-three Vertical Up and
three Vertical Down as illustrated below.
Components:
Weatherproof unit -for outdoor
installations with insulated blower section and unit controls mounted in NEMA 3d
enclosure.
Insulated coil section - available on all
units.
Inlet air shut-off damper - replaces
mixing dampers for 100% outside air applications on VA or VB sequences. Low leakage
dampers are also available.
Stormproof weatherhood - with rain shield
and bridscreen, Installed on air intake of horizontal, HR-1 and HR-2, weatherproof units.
Not available with optional vertical blower arrangement
Birdscreen - for installation on the air
intake of units with optional vertical blower arrangement.
Filter section - with 2" cleanable or
extended surface filters. Filter section can also be insulated.
Discharge air louvers - adjustable
horizontal or vertical bladed louvers are available for mounting on the blower outlet.
These louvers can be combined for double deflection air control.
Service platform - with guardrail per OSHA
standard. Service platforms are available for indoor horizontal units only.
Vibration isolators - either
"rubber-in -shear" or spring type for floor mounting, roof mounting, or indoor
suspension. Vibration isolators are shipped unmounted. Internal fan/motor isolation is also
available.
Extended grease lines - for remote
greasing of fan bearings from control side of unit. Not available with SB-112 or SB-115
models.
Variable pitch sheave - for motors 15HP
and larger. Variable pitch sheaves are standard for motors 10 HP and smaller.
Motors :
Totally enclosed, two speed, explosion
proof and chemical duty motors are available on all units.
Coils :
- High pressure steam coils with cupro-nickel tubes.
- Copper fins.
Electric Controls :
- Clogged fitter switch with indicating light.
- Automatic mixed air temperature controller.
- Low outlet temperature shut-off.
- Fused disconnect switch (dead front type) or circuit breaker
mounted in cover of main control box.
Roof Curbs :
Adapter frames and roof curbs available for horizontal
units. Curbs are shipped knocked down.
Miscellaneous :
Motor and controls can be mounted on opposite side.
Matching cooling coil and evaporative cooling sections for
all models.
VERTICAL UNIT BLOWER
DISCHARGE ARRANGEMENTS
(All sections and components are supported
by special base frame and vertical support channels)
(Standard support channel heights 112 thru
218-24", 222 thru 233-26", 240-48")


|