Horner Flooring Co. Specifiers Product Guide 1998 Suspended Systems
|
VARI-CUSHION SYSTEM Vari-Cushion is a specially-designed cushioned sport flooring system. A
continuous layer of 1/4" polyethylene foam supports the ever-popular Thrust-A-Cushion
pads, providing two distinct levels of shock absorption. Light loads only compress the
polyethylene foam, while heavier loads compress both foam and Thrust-A-Cushion pads. The
transfer of forces takes place smoothly and energy is returned to the participant in an
efficient manner.
MATERIALS - VARI-CUSHION SYSTEM
- Finish Flooring: 33/32" or 25/32" thick x 2
1/4" or 1 1/2" wide, continuous tongue and groove and end-matched Horner
Northern Hard Maple, treated with WOODLIFE F preservative if so specified. OPTION: Horner
Multisport, 5/16" or 11/16" thick Second and Better Grade.
- Foam Layer: 1/4", multicellular, closed cell polyethylene
Vari-Cushion foam.
- Cushion Pads: 2 1/4" x 3" x 3/8" - or
5/8"- thick Thrust-A-Cushion pads.
- Subfloor: 15/32" APA-rated sheathing grade plywood,
exposure 1, or 7/16" OSB.
- Wall Base: 3" x 4" Ventcove heavy duty molded,
vented vinyl base with premolded outside corners and mitered inside corners.
SLAB DEPRESSION
- Concrete slab depression shall be 2 1/4" for 25/32"
flooring, or 2 1/2" for 33/32" flooring. For 5/8" pad, add 1/4" to
depression. For MultiSport flooring, subtract 1/4" from depression.
|
ALL-WOOD, FR, FR-1 SYSTEMS An all-wooden subfloor assembly that provides uniform resiliency, excellent
shock absorption, and a high level of energy return. The actual level of shock absorption
can be controlled by adjusting the spacing between the 1" x 6" 's (nominal). The
system will provide the desired level of resiliency for any activity, from basketball to
aerobics.
MATERIALS - STA FAST SYSTEM
- Finish Flooring: 25/32" or 33/32" thick x 2
1/4" or 1 1/2" wide, continuous tongue and groove and end-matched Horner
Northern Hard Maple, treated with WOODLIFE F preservative if so specified.
- Subfloor: 1" x 6" (nominal) Second and Better Gym
Grade Hemlock, No. 2 spruce, Fir, or Pine S2S to 3/4" x 6" x RL, treated with
WOODLIFE F preservative if so specified. OPTION: 2 layers of 1/32" sheathing plywood,
exposure 1, or 7/16" OSB.
- Horner Foam: 1/4" multi-cellular, closed cell plastic
foam. 1/4" x 3" foam strips for FR and FR-1 systems. Density: 2.0 PCF.
- Wall Base: 3" x 4" Ventcove heavy-duty molded,
vented vinyl cove base with pre-molded outside corners and mitered inside corners.
SLAB DEPRESSION
- Concrete slab depression shall be 2 1/2" for 25/32"
flooring, or 2 3/4" for 33/32" flooring. For plywood or OSB subfloors, subtract
1/2" or 5/8", respectively, from slab depressions.
|
SAFE ALL-WOOD FR, FR-1 SYSTEMS The Horner SAFE All-Wood FR System is a true all-wooden sports flooring
system, specially designed to provide a level of impact force reduction exceeding DIN
18032, Part 2 performance requirements. With its superb shock absorption characteristics
this system reduces leg fatigue and exhibits outstanding playing characteristics.
MATERIALS - FIXED SLEEPER SYSTEM
- Finish Flooring: 25/32" thick x 1 1/2" or 2
1/4" wide, continuous tongue and groove and end-matched Horner Northern Hard Maple,
treated with WOODLIFE F preservative if so specified.
- Subfloor: 1" x 6" (nominal) Second and Better Gym
Grade Hemlock, No. 2 spruce, Fir, or Pine S2S to 3/4" x 6" (nominal) x RL,
treated with WOODLIFE F preservative if so specified.
- Cushion Pads: 7/16" or 3/4" Horner SAFE pad.
- Wall Base: 3" x 4" Ventcove heavy-duty molded,
vented vinyl cove base with pre-molded outside corners and mitered inside corners.
SLAB DEPRESSION
- Concrete slab depression shall be 2 3/4" for 7/16"
SAFE pad, or 3" for 3/4" SAFE pad.
|
 |