architecture - engineering - construction
Horner Flooring Co.
Specifiers Product Guide 1998
Safe Suspended Systems
Specifiers Product Guide 1998
|
SAFE SLEEPER SYSTEM The
SAFE Sleeper System incorporates a 2" x 3" x 4' (nominal) sleeper, treated
with Woodlife F, and padded with five SAFE Pads. As with all SAFE Systems the
performance characteristics can be selected from any of the twelve possible pad/insert
combinations.
MATERIALS - SAFE SLEEPER SYSTEM
- Finish Flooring: 25/32" or 33/32" thick x 1
1/2" or 2 1/4" wide, continuous tongue and groove and end-matched Horner
Northern Hard Maple, treated with WOODLIFE F preservative if so specified.
- SAFE Sleepers: 2" x 3" x 4' (nominal) SPF
regular or R-1, kiln dried and treated with WOODLIFE F preservative, and padded with
either 7/16" or 3/4" SAFE pads. Optional Horner R-I sleepers notched to
accept Horner R-I galvanized retainer or R-II sleepers predrilled to accept retaining pin,
when so specified.
- Wall Base: 3" x 4" Ventcove heavy duty molded, vented vinyl
base with premolded outside corners and mitered inside corners.
SLAB DEPRESSION
- Concrete slab depression when using 7/16" SAFE pads shall
be 2 11/16" for 25/32" thick flooring, and 2 15/16" for 33/32" thick
flooring. For 3/4" pads add 5/16" to the dimensions above.
|
SAFE SLEEPER SUBFLOOR SYSTEM The SAFE Sleeper Subfloor system utilizes the same sleepers as does the
SAFE Sleeper System, but a layer of either 15/32" plywood or 7/16" OSB is
incorporated between the sleepers and the flooring. The subfloor ties the flooring
together to help make the floor more uniform and help eliminate "dead spots".
MATERIALS - SAFE SLEEPER SUBFLOOR SYSTEM
- Finish Flooring: 25/32" or 33/32" thick x 1
1/2" or 2 1/4" wide, continuous tongue and groove and end-matched Horner
Northern Hard Maple, treated with WOODLIFE F preservative, if so specified.
- SAFE Sleepers: 2" 3" x 4' (nominal) SPF
kiln dried, treated with WOODLIFE F preservative, and padded with either 7/16" or
3/4" SAFE pads. Optional Horner R-I sleepers notched to accept Horner R-I
galvanized retainer or R-II sleepers predrilled to accept retaining pin, when so
specified.
- Subfloor: 15/32" APA-rated sheathing grade plywood,
exposure 1, or 7/16" OSB.
- Wall Base: 3" x 4" Ventcove heavy duty molded,
vented vinyl base with premolded outside corners and mitered inside corners.
SLAB DEPRESSION
- Concrete slab depression when using 7/16" SAFE pads shall
be 3 1/8" for 25/32" thick flooring, or 3 3/8" for 33/32" thick
flooring. For 3/4" pads add 5/16" to the dimensions above..
|
SAFE PANEL SYSTEM The SAFE Panel System incorporates two layers of either 15/32"
sheathing grade plywood or 7/16" OSB with the SAFE pads stapled to the bottom
layer. This system provides for an even greater degree of fine tuning of the performance
characteristics by altering the spacing between the layers of plywood.
MATERIALS - SAFE PANEL SYSTEM
- Finish Flooring: 25/32" or 33/32" thick x 1
1/2" or 2 1/4" wide, continuous tongue and groove and end-matched Horner
Northern Hard Maple, treated with WOODLIFE F preservative, if so specified. OPTION:
Horner MultiSport, 5/16" or 11/16" thick Second and Better Grade.
- Cushion Pads: 7/16" or 3/4" Horner SAFE pad.
- Subfloor: 15/32" x 4' x 8' APA-rated sheathing plywood,
exposure 1, or 7/16" OSB.
Subfloor Restraints: Special R-II pin restraint, when so specified.
- Wall Base: 3" x 4" Ventcove heavy duty molded,
vented vinyl base with premolded outside corners and mitered inside corners.
SLAB DEPRESSION
- Concrete slab depression when using 7/16" SAFE pads shall
be 2 1/8" for 25/32" thick flooring, or 2 3/8" for 33/32" thick
flooring. For 3/4" pads add 5/16" to the dimensions above. For MultiSport
flooring, subtract 1/4" from depression.
|
 |
Specifications are
available through our FAST-FAX Information System at 1-800-464-7556... |