  Hubbell Lighting Inc   Hubbell Lighting Buyers Guide\ 4 — Emergency Lighting Products  

Freedom Series Exit Signs - Page 11

   

Hubbell Lighting Buyers Guide\ 4 — Emergency Lighting Products

hublogo.jpg (8655 bytes) Freedom Series Exit Signs

AC-Only  and Battery Backup / LED

hble010b.jpg (14016 bytes)

  • Available in AC-only or with battery backup
  • Vinyl coated aluminum housing (marine grade 5052-H32)
  • Available in black, white, polished brass & antique brass
  • Vandal resistant polycarbonate face shield
  • 80-year lamp life
  • 12-hour emergency run time (single face), 8-hour (double face) with flasher
  • Universal mounting (canopy included)
  • Universal knockout chevrons
  • 10 footcandle face illumination exceeds UL 924 standard illumination requirements
  • Low-voltage disconnect
  • 24-hour recharge time
  • Flasher standard in emergency mode (field selectable on battery units)
  • LED ac indicator
  • Push-to-test switch
  • 3-year full warranty on battery, plus
  • 5 years prorated
  • UL 924 damp location listed
  • 6V, sealed, maintenance free battery

 


California Series / LED

hble010c.jpg (12310 bytes)

  • Available in AC-only or with battery backup
  • Vinyl coated aluminum housing (marine grade 5052-H32)
  • Available in black, white, polished brass & antique brass
  • Vandal resistant polycarbonate face shield
  • 80-year lamp life
  • 6-hour emergency run time (with flasher), 4-hour (without flasher)
  • Universal mounting (canopy included)
  • Universal knockout arrows
  • 10 footcandle face illumination exceeds UL 924 standard illumination requirements
  • Low-voltage disconnect
  • 24-hour recharge time
  • Lockout protection
  • Flasher standard in emergency mode (field selectable on battery unit)
  • LED AC indicator
  • Push-to-test switch
  • Three year full warranty on battery, plus five years prorated
  • Master Unit with capacity to run one remote
  • Remote Unit feature slim profile (1" deep)
  • Low voltage Class II wiring from master
  • Meets California code requiring low level exit sign
  • UL 924 damp location listed
  • 6V, sealed, maintenance free battery

 

 

New York City Metro Series — AC / Battery Backup / LED

hble010d.jpg (12096 bytes)

  • Available in AC only or with battery backup
  • Vinyl coated aluminum housing (marine grade 5052-H32)
  • Available in black, white, polished brass & antique brass
  • Vandal resistant polycarbonate face shield
  • 80-year lamp life
  • 12-hour emergency run time (single face), 6-hour (double face)
  • Universal mounting (canopy included)
  • Universal knockout arrows
  • 10 footcandle face illumination exceeds U.L. 924 standard illumination requirements
  • Low-voltage disconnect
  • 24-hour recharge time
  • Flasher standard in emergency mode (field selectable on battery units)
  • LED AC indicator
  • Push-to-test switch
  • 3-year full warranty on battery, plus 5 years prorated
  • 6V, sealed, maintenance free battery
  • NYC Calendar #36469 June ‘93

 

 

Freedom — 1248 Units / LED

hble010e.jpg (15378 bytes)

  • Vinyl coated aluminum housing (marine grade 5052-H32)
  • Available in black, white, polished brass & antique brass
  • Vandal resistant polycarbonate face shield
  • 80-year lamp life
  • Universal mounting (canopy included)
  • Universal knockout arrows
  • 10 footcandle face illumination exceeds UL 924 standard illumination requirements
  • 120/277V power supply (normal AC)
  • 3 year full warranty on electronics and LEDs
  • UL 924 damp location listed

 

 

System 10 / LED

hble010f.jpg (13595 bytes)

Master/Remote System 10 consists of a master unit capable of operating up to 10 remote faces.

  • 80 year LED lamp life
  • Vinyl coated aluminum housing (marine grade 5052-H32)
  • Available in black, white, brass or brushed aluminum
  • Vandal resistant polycarbonate face shield
  • Conformal coated electronics
  • 120/277V input
  • 4-hour emergency run time
  • Universal mounting (canopy included)
  • Universal knockout arrows
  • Less than 1.9 watts per face at full load
  • 10 footcandle face illumination exceeds UL 924 Standard illumination requirements
  • Precision regulated charger
  • Conforms to OSHA and NEC standards
  • NFPA-101 LIFE Safety Code
  • Low voltage disconnect
  • Lockout protection
  • Flasher standard in emergency mode (battery units)
  • Sealed, maintenance-free batteries
  • Long life LED AC indicator
  • Push-to-test switch
  • Three year full warranty on battery, electronics, and LEDs; five additional years prorated on battery
  • UL Listed for damp locations (remote)
  • Available in intrinsically safe, hazardous location (consult factory)
  • Remote unit feature slim profile (1" deep)
  • Low voltage Class II wiring from master
  • Meets California code requiring low level exit signs
  • California Title 24
  • NYC Calendar #32168 Oct. 87
  • 12V system for 500" runs to remote exits

 

Sample catalog Number
AC ONLY AND BATTERY BACKUP CATALOG LOGIC

hble010g.gif (2039 bytes)

hble010h.gif (4222 bytes)

hble010i.gif (5056 bytes)
Note:  Order accessories separately

 

Sample catalog Number
CALIFORNIA SERIES ( MASTER & REMOTE) CATALOG LOGIC

hble010j.gif (2017 bytes)

hble010k.gif (3841 bytes)

hble010l.gif (5037 bytes)
Note:  Order accessories separately

 

Sample catalog Number
NEW YORK CITY METRO SERIES CATALOG LOGIC

LED M 1 - AC - R - W - W - BPR
Metro 8"
Letters
LEDM Metro NYC faces operation letter color housing color stencil color options

hble010m.gif (4015 bytes)

hble010n.gif (5535 bytes)
1  Not available on Metro (NYC) exit.
Note:  Order accessories separately

 

Sample catalog Number
SYSTEM 10 MASTER UNIT CATALOG LOGIC

hble010o.gif (1797 bytes)

hble010p.gif (2856 bytes)
Note:  Order accessories separately

 

Sample catalog Number
SYSTEM 10 REMOTE UNIT CATALOG LOGIC

hble010q.gif (1876 bytes)

hble010r.gif (3936 bytes)

hble010s.gif (4115 bytes)
1.  ISH - Wire 200' or 500' coil
Note:   ISH - Wire 500 (ft)
           2 conductor wire for use with ISH - Must be provided
           by factory for UL Listing
Note:  Order accessories separately.

 

Sample catalog Number
1248 EXIT CATALOG LOGIC

hble010t.gif (2134 bytes)

hble010u.gif (4432 bytes)

hble010v.gif (3532 bytes)
Note:  Order accessories separately.

 

ACCESSORIES - Must be ordered separately

hble010w.gif (4990 bytes)

1.  For correct color, replace X with B - black, T - brass, W - white, Z - antique brass
2.  Consult factory for EM-Recess.
3.  For remote unit.

 

ELECTRICAL DATA

hble010z.gif (2560 bytes)

 

ELECTRICAL DATA

hble010x.gif (3733 bytes)

 



Request for Information / Request a Catalog from Hubbell Lighting Inc
 
 
 
To request more information from Hubbell Lighting Inc, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.