OPTIONS — Factory Installed. Order with Fixture by adding suffix.
Suffix |
Description |
CFB |
Charcoal Filter Breather - EG Series only. |
CXHL |
Cord and Hook/Loop with Quick-On® Hanger - SO cord wired thru hook
(specify cord length - see section notes.) |
CXHLP (X1) |
Cord and Hook/Loop with Quick-On® Hanger - SO cord with plug6 wired thru hook
(specify voltage)1 (specify cord length - see notes.) |
CXHLP1-15A |
Cord and Hook/Loop and 15A 120 Volt Plug with Quick-On® Hanger - SO cord with
plug6 wired thru hook (specify cord length - see notes.) |
CXHLP4-15A |
Cord and Hook/Loop and 15A 277 Volt Plug with Quick-On® Hanger - SO cord with
plug6 wired thru hook (specify cord length - see notes.) |
CXHLPSO (X1) |
Cord and Hook/Loop and Plug with Slick-On® Hanger - SO cord with plug6 wired thru
hook (specify voltage)1 (specify cord length - see notes.) |
CXHLPSO1-15A |
Cord and Hook/Loop and 15A 120 Volt Plug with Slick-On® Hanger - SO cord with
plug6 wired thru hook (specify cord length - see notes.) |
CXHLPSO4-15A |
Cord and Hook/Loop and 15A 277 Volt Plug with Slick-On® Hanger - SO cord with
plug6 wired thru hook (specify cord length - see notes.) |
CXHLPSOF (X2) |
Cord and Hook/Loop and Plug with Slick-On® Hanger - single fuse (included) SO cord
with plug6 wired thru hook (specify voltage)3 (specify cord length - see notes.) |
CXHLPSOFF (X3) |
Cord and Hook/Loop and Plug with Slick-On® Hanger - double fuse (included) 24" SO
cord with plug6 wired thru hook (specify voltage)3 (specify cord length - see notes.) |
CXHLSO |
Cord and Hook/Loop with Slick-On® Hanger - SO cord wired thru hook
(specify cord length - see notes.) |
CXHLSOF (X2) |
Cord and Hook/Loop with Slick-On® Hanger - single fuse (included) SO cord wired thru
hook/Loop (specify voltage)3 (specify cord length - see notes.) |
CXHLSOFF (X3) |
Cord and Hook/Loop with Slick-On® Hanger - double fuse (included) SO cord wired thru
hook (specify voltage)4 (specify cord length - see notes.) |
DFP (X1) |
Dead Front Disconect - Includes cord, loop and dead front disconnect plug with Quick-On®
hanger - 15" SO cord factory wired to the fixture. Order with PHS-XXXL
(see mounting accessories) (specify voltage)1 |
DFPF (X2) |
Dead Front Disconect with Single Fuse - Includes cord, loop and dead front disconnect
plug plus single fuse block (fuse included) with Quick-On® hanger - 15" SO cord factory
wired to the fixture. Order with PHS-XXXL (see mounting accessories) (specify voltage)3 |
DFPFF (X3) |
Dead Front Disconect with Double Fuse - Includes cord, loop and dead front disconnect
plug plus double fuse block (fuses included) block with Quick-On® hanger - 15" SO cord
factory wired to the fixture. Order with PHS-XXXL (see mounting accessories) (specify
voltage)4 |
DFPSO (X1) |
Dead Front Disconect - Includes cord, loop and dead front disconnect plug with Slick-On®
hanger - 15" SO cord factory wired to the fixture. Order with PHS-XXXL (see mounting
accessories) (specify voltage)1 |
DFPSOF (X2) |
Dead Front Disconect with Single Fuse - Includes cord, loop and dead front disconnect
plug plus single fuse block (fuse included) with Slick-On® hanger - 15" SO cord factory wired
to fixture. Order with PHS-XXXL (see mounting accessories) (specify voltage)3 |
DFPSOFF (X3) |
Dead Front Disconect with Double Fuse - Includes cord, loop and dead front disconnect
plug plus double fuse block (fuse included) with Slick-On® hanger - 15" SO cord factory
wired to fixture. Order with PHS-XXXL (see mounting accessories) (specify voltage)4 |
EM |
Emergency Circuit Complete with Slick-On® Hanger - D.C. bayonet base 120V quartz
socket. For connection by customer to separate power supply |
LRI2 |
Lower Luminaire retainer - A snap-in cable secures reflector to ballast housing. |
M52 |
White Lektrocote® Finish on housing |
NMM |
No Mounting Method - Neither Slick-On® nor Quick-On® provided with luminaire. Mounting
method must be ordered as an accessory. Option used for applications requiring mounting
method supplied in advance of luminaire. |
P |
High Strength Polycarbonate Refractor - LBI, LM Series only. |
QSS |
Quartz Standby System - On when power is restored, Off when HID lamp restrikes.
Wattage of quartz lamp (not included) may not exceed wattage of HID lamp. (250W max.
recommended). Uses 120Vdc bayonet base lamp. Factory wired. |
SLD-1 |
Switch Level Dimming with 120V control5 |
SLD-2 |
Switch Level Dimming with 24V control5 |
SLD-3 |
Switch Level Dimming with 277V control5 |
SO |
Slick-On® thru wire outlet box for 3/4" pendant or side entry conduit. |
SOF (X2) |
Slick-On® thru wire outlet box, single fuse (included) (specify voltage)3 |
SOFF (X3) |
Slick-On® thru wire outlet box, double fuses (included) (specify voltage)4 |
TRI (X4) |
Top Luminaire Retainer - Chain secures ballast housing to structure when additional
safety precautions are required. Shipped in housing carton. Specify length. Recommended
maximum slack - 3". |
UP |
Unit Pack - Ballast housing. Quick-On® hanger, and reflector in one box. (consult factory for
availability) BI series only. |
Note: To specify cord length substitute "X" as follows: 2-2 Ft., 4-4 Ft., 6-6 Ft., 8-8 Ft., 10-10 Ft., 12-12 Ft.
1. To specify voltage substitute (X1) as follows: 1-120V, 2-208V, 3-240V, 4-277V, 5-480V, 6-347V
2. Luminaire retainers/safety cables reduce risk of equipment falling.
3. To specify voltage substitute "X2" as follows: 1-120V, 4-277V, 6-347V.
4. To specify voltage substitute "X3" as follows: 2-208V, 3-240V, 5-480V.
5. For Motion Sensor and Switch Level Interface Panel accessories see Controls.
6. Twistlock plug.
7. To specify length, substitute "X4" as follows: 6-6', 10-10', 12-12', 16-16'.
ACCESSORIES - Must be ordered separately
Catalog Number |
Description |
BL-LR-14 |
14" Tempered Glass Lens - thermal shock and impact resistant. Gasketed on corrosion
resistant steel lens ring (not dust tight). Required for 175 and 250W MH luminaires. For BI
reflector only. Not for use in combination with wireguard. |
BL-LR-19 |
19" Tempered Glass Lens - thermal shock and impact resistant. Gasketed on corrosion
resistant steel lens ring (not dust tight). Required for 175 and 250W MH luminaires. For SU,
SD, and AL reflector series only. |
BL-WG19 |
19" Wireguard - corrosion resistant, welded steel with center lamp access. For EG, SU, SD
and AL reflectors only. |
B-LLR1 |
Lower luminaire retainer - cable secures reflector to ballast housing. |
BL-PK-ENC |
16" Plastic lens - Flat 1/8" acrylic lens for "PA2" 16" reflector. Required with 175W and 250W
Metal Halide. |
BL-TLR(X4)1.5 |
Top luminaire retainer - Chain secures ballast housing to structure when additional safety
precautions are required. Specify length. |
BL-SO |
Slick-On® thru wire outlet box for 3/4" conduit, or pendant mount. |
BL-SOF |
Slick-On® single fusing (fuse not included) thru wire outlet box for 3/4" conduit, or pendant
mount with single fuse. |
BL-SOFF |
Slick-On® double fusing (fuses not included) thru wire outlet box for 3/4" conduit, or pendant
mount with two fuse holders. |
BL-QO |
Quick-On® 3/4" pendant mount. |
BL-WG16 |
16" Wireguard - corrosion resistant, welded, steel with center lamp access. For 16" PA2
reflector only. |
RG-14 |
14" Wireguard - corrosion resistant, welded plated with center lamp access. For BI reflector
only. Not for use in combination with BL-LR-14 |
WA2-ENC |
22" Flat Plastic lens - Flat 1/8" acrylic lens for "WA" and "WD" acrylic reflectors. (40°C
operation recommended) |
WA22-CDL |
22" Drop on Plastic lens - Conical drop lens for WA acrylic reflector. (40°C operation
recommended. |
HOOK/LOOP |
Hook - cast aluminum 3/4" NPS male. Includes safety screw. Static pull tested to 625 lbs.
Converts to Loop with strap included. |
H3/4AL3/4 |
Swivel Aligner - complete with box for thru wiring. All hubs tapped for 3/4" conduit. |
PHE-XXX4 |
Die cast aluminum power hook with Twist-Lock® receptacle - ceiling or 3/4" pendant
mount, with 3/4" side entry for thru wiring. Cord, loop and plug (20amp) included. |
PHE-XXX-L2,4 |
As above, except cord, loop, and plug not included. |
PHS-XXX4 |
Specification Grade Power Hook - dead front plug and receptacle with isolated wiring
chamber. Ceiling or 3/4" pendant mount, with 3/4" side entry for thru wiring. Special safety
feature locks Hook/Loop onto bottom hook when engaged. |
PHS-XXX-L3,4 |
As above except cord, loop and dead front plug not included. |
SY3-XXX-24 |
Rugged steel power hook - pendant or surface mount, 3/4" thru wiring capability. Cord, loop,
and plug (20 amp) included. |
SY3-XXX-L2,4 |
As above, except cord, hook/loop and plug not included. |
1. Luminaire retainers/safety cables reduce risk of equipment falling.
2. Cord, Hook/Loop, and Plug must be added to fixture as option, example: "-C2HLP4"
3. Cord, Hook/Loop, and Dead Front Plug must be added to fixture as option, example: "-DFP4".
4. To specify voltage, replace "XXX" with 120, 208, 240, 277, 347, 480.
5. To specify length, substitute X4 as follows: 6-6'. 10-10', 12-12', 16-16'. |