   Hydro-Craft, Inc.  Line Clamping Systems  

The Multi-Clamp-Page 7

 

 

hydro04b.JPG (3611 bytes) 
The Multi-Clamp®
SELF-TAPPING ADAPTER
hydro07a.JPG (5145 bytes) 1 . Using a scale, or the Clamping Unit itself measure and mark location on mounting surface for each mounting hole of the lower Clamping Unit. Note that all mounting holes are spaced at even increments.
hydro07b.JPG (6566 bytes)
hydro07c.JPG (7140 bytes) 2. Drill appropriate size hole for particular MULTI-CLAMP series being installed.

3. Place Self-tapping Adapter into speed wrench and insert into each hole until seated securely
hydro07d.JPG (8020 bytes)

hydro07k.JPG (7363 bytes)
4. Align lower Clamping Unit over Self-tapping Adapters and position by placing the Adapters through mounting holes.

5. Thread Stacking Nut onto each Self-tapping Adapter until finger tight.

6. Tighten all Stacking Nuts securely and proceed with remainder of installation.
hydro07f.JPG (7329 bytes)
STANDARD BOLT, LOCKWASHER AND STACKING NUT FOR DRILLED HOLE (A)

THREAD ADAPTER FOR DRILLED HOLE (B)
hydro07g.JPG (5896 bytes)

hydro07h.JPG (7019 bytes)

1. (A & B) Using a scale, or the Clamping Unit itself, measure and mark location on mounting surface for each mounting hole of the lower Clamping Unit. Note that all mounting holes are spaced at even increments.

2. (A & B) Drill appropriate size hole for particular MULTI-CLAMP series being installed.
hydro07k.JPG (7363 bytes)
hydro07i.JPG (6430 bytes)
3. (A) Position lower Clamping Unit over tapped holes. Place standard bolt and lockwasher through drilled hole and through lower Clamping Unit. Attach with stacking nut finger tight.

4. (A) Tighten securely and proceed with remainder of installation.
hydro07j.JPG (5207 bytes)

hydro07k.JPG (7363 bytes)
hydro07l.JPG (6096 bytes)

3. (B) Assemble required number of Stacking Nuts and Thread Adapters for each mounting hole.

4. (B) Position lower Clamping Unit over drilled holes. Place threaded portion of assembled Thread Adapter-Stacking Nut through both lower clamping unit mounting hole and drilled hole.

5. (B) Attach lockwasher and nut. Tighten to secure Clamping Unit and proceed with remainder of installation.

Request for Information / Request a Catalog from Hydro-Craft, Inc.
 
 
 
To request more information from Hydro-Craft, Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com