Inclinator Co. of America Inc.
Residential Elevators & Stairway Lifts
Inclinator Company of America Page - 4
Residential Elevators & Stairway Lifts
| Specifications TS/Technical Support Furnish and install Inclinator Company of America Elevette or Elevette 2100 to travel a distance of ______ feet and _____ inches, serving _______ stops and ________ door openings in line. The Elevette or Elevette 2100 shall have a capacity of 500/750 pounds and speed of 30 feet a minute, (as recommended by American Standards Safety Code.) Electric Requirements - Elevette and Elevette 2100 operates on available power supply, such as 230 volts, 60 Hz., single phase alternating current; or 220/440 volts, three phase, 60 Hz. 50 Hz. equipment available for export. Control voltage is 24 volts. For operation on _______ volts ________ phase ________ Hz. The drum type machine shall consist of a high torque electric motor and a completely enclosed worm and gear. The magnetic brake shall be spring applied and electrically released, and energized only when the motor is running. A threaded winding drum or drums will accommodate two 1/4" x 8 x 19 improved plow steel cables (3/8" x 8 x 19 on 750# unit). Power unit shall be located in basement below bottom landing _________, attic floor _________, or adjacent to shaft at ________ landing. The car shall be _______ inches in depth (distance out from rail) and ________ inches in width. Elevette car height 6' 7" or to 7'. Elevette 2100 - 7' height overall. Car shall be constructed of auto steel panels _________, perforated steel panels __________, or hardwood panels (mention wood choice) Color card or wood sample will be furnished manufacturer for solid grained finish ________. Other type (give details) _____________. Elevette 2100 Models available with 3/8" veneer plywood, tempered hardboard, acrylic mirror, clear or tinted acrylics, wood with plastic laminate or unfinished panels. Advise if necessary for gate to reject 3" ball. Yes ____ No ____ The car shall be equipped with _________ collapsible gates (see car code arrangements below). Swing type shaft doors shall be electrically and mechanically interlocked. Controls shall be momentary pressure, automatic type, with call buttons at each floor and a bank of car control buttons with a stop button and light switch. Terminal and overrun limit switches shall be furnished, together with a slack cable mainline disconnect switch. Car lighting can be swivel, surface mounted, or semi-recessed incandescent or fluorescent type. Optional Equipment - Floating safety gate, gate open alarm, brass or wood handrails, folding shelf, key switch operation, vinyl floor covering, signal bell, telephone cord, special car heights, special leg extension pan, in-use and arrival lights, emergency lighting, machine limit and auxiliary car stabilizing rollers. DETAILS |




